Ø
If the transceiver does not receive a valid signal from
a wireless siren, or a repeater, inside the
Wireless
Supervisory Window
, the control panel generates the
System
>
System Fault
event.
+
The
System
>
System Fault
event does not distin-
guish the wireless siren or the repeater that causes
it; this information can be found in the logger.
Valid values:
Disabled, After 1 Hour(s), After 2 Hour(s),
After 4 Hour(s), After 8 Hour(s), After 12 Hour(s), After
24 Hour(s).
Default:
After 2 Hour(s).
Tamper Enabled
If this option is disabled, the trans-
ceiver does not report opening and removal from the
mounting surface.
Default:
enabled.
Jam Detection
If this option is enabled, the trans-
ceiver detects and reports RF jamming, based on the
selected value:
Ø
UL 20/20
, continuous RF jamming for 20 seconds,
suitable for installation in the USA;
Ø
EN 30/60
, 30 seconds of accumulated jamming
within 60 seconds, suitable for installation in Europe.
Default:
EN 30/60.
The control panel signals the RF jamming detected by
the transceiver, as shown in Table 8.
n
Wireless Detectors
The
Wireless Detectors
option group is for wireless de-
tectors enrolling, as described below.
#
In the column #, choose a free position to enroll the
wireless device.
Label
In the
Label
option, enter a meaningful label for
the wireless device: the entered label is used to identify
the device in the
Zones
option group, for associating the
device with a logical zone.
Valid Values:
up to 16 characters.
Default:
Detector 1, Detector 2, etc.
Device ID
In the
Device ID
option, enter the ID number
that you find on the wireless device: if a valid ID number
is entered, the console shows the corresponding type of
wireless device, and the options that you can set for that
type of device. Set the wireless device options as indi-
cated in “Wireless device options” on page 128.
Enter all zeros to remove a wireless device.
Valid Values:
three digits for the device type, and four
digits for the serial number.
Default:
000-0000.
n
Wireless Sirens
The
Wireless Sirens
option group is for wireless sirens
enrolling, as described below.
#
In the column #, choose a free position to enroll the
wireless device.
Label
In the
Label
option, enter a meaningful label for
the wireless device: the entered label is used to identify
the device in the
Outputs
option group, for associating
the device with a logical output.
Valid Values:
up to 16 characters.
Default:
Siren 1, Siren 2, etc.
46
Expandable Hybrid Control Panel
Keypad
Device
Event
Class
Icon
Message
Transceiver
Device lost
Tamper
s
WLS rec. lost
Transceiver
Tamper
Tamper
b
WLS receiver
Transceiver
RF jamming
Tamper
b
WLS receiver
Wireless Detector
Device fault
Fault
—
Fail detect.
nn
Repeater
Low battery
Fault
—
No
Repeater
AC fault
Fault
—
No
Repeater
Device fault
Fault
—
No
Repeater
Tamper
Tamper
b
Generic Tamper
Repeater
Device lost
Tamper
—
No
Wireless Siren
Low battery
Fault
—
No
Wireless Siren
Device fault
Fault
—
No
Wireless Siren
Tamper
Tamper
—
Generic Tamper
Wireless Siren
Device lost
Tamper
—
No
Keyfob
Device fault
Fault
—
No
Table 8
The control panel signals the events relating to wireless devices with the occurrence of the event indicated in
the
Events and Actions
column; the keypad lights the light indicated in the
Class
column and, the LCD keypad shows
an X above the icon indicated in the
Icon
column; ...