ABSOLUTA Plus
INTRODUCTION
13
Versions
ABS18P15
ABS18P35
ABS48P35
ABS48P50
ABS128P50
ABS18M35
ABS48M35
ABS48M50
ABS128M50
ABS48M75
ABS128M75
ABS128M75-G3
Voltage
230 V
~
-15/+10%
50/60 Hz
110-230 V
~
-15/+10% 60-50 Hz
Max. Current Draw
0.42 A
0.75 A
1.1 A
0.75 A
1.1 A
1.7 A
Power Supply Battery-Charger
(Type A - EN50131-6)
13.8 V
_
±2% 1.5 A
13.8 V
_
±1% 2.6 A
13.8 V
_
±1% 3.6 A
13.8 V
_
±1% 2.6 A
13.8 V
_
±1%
3.6 A
13.8 V
_
±1%
5.4 A
Insulation Class
I
Maximum ripple voltage on
the outputs
310 mV (2.25%)
Battery
(Brand and Type)
Lead Acid 12 V / 7 Ah
YUASA NP 7-12 FR or
similar Case Flame Class UL94-V2 or
higher
Lead Acid 12 V / 17 Ah
YUASA NP 17-12 FR or
similar Case Flame Class UL94-V2 or higher
Max. Current available for
peripherals and loads (Aux
Output)
380 mA
(7 Ah battery)
1200 mA
*
(17 Ah battery)
Max. Battery Charge Current
(Battery capacity)
0.92 A
(7 Ah)
2.02 A
(7 Ah)
3.02 A
(7 Ah)
1.2 A
(17 Ah)
2.2 A
(17 Ah)
4.0 A
(17 Ah)
Maximum Battery Recharge
Time to 80%
24 h
Minimum Duration of
Alternative Power Supply
12 h
Low Battery Fault
Generated
11.4 V
Generation of Low Output
Voltage Fault, without
backup batteries
11.2 V
Overvoltage Protection
N/A
16.7 V
Deep Discharge Protection
9.6 V
Digital Key Combinations
4,294,967,296
Alarm Transmission System
(ATS)
SP2 (with built-in PSTN communicator)
SP5 (with
ABS-GSM
or
ABS-IP
module)
DP1 (with integrated PSTN communicator and
ABS-GSM
or
ABS-IP
module)
DP4 (with
ABS-GSM
and
ABS-IP
modules)
Interface type between SPT
and AS**
Proprietary
Alarm transmission operation
mode (acknowldgement)
Pass-through
Delay for alarm messages
generation and
transmission
2 s
Delay for fault detection and
visualization
2 s
IP Protection Grade
IP20
Security Grading
2 (3 for
ABS128M75-G3
control panel)
Environmental Class
II
Operating Temperature
-10 to +40 °C
Operating Humidity (not
condensed)
0 to 93% RH
Dimensions (WxHxD)
319x352x92 mm (without antenna)
310x403x103 mm (without antenna)
Weight
2.09 Kg (without battery)
4.89 Kg (without battery)
Complies with
EN60950-1; EN50130-4; EN50131-1; EN50136-2
Table 4
Technical Specifications:
*) 350 mA
for Grade 3 Control Panels connected to a Central Station;
500 mA
in or-
der to comply with the T 031 standard, for
ABS128M50
,
ABS128M75-G3
,
ABS48M50
, and
ABS18M35
control pan-
els, that must be connected to a Central Station;
**)
Supervised Premises Transceiver (Communicator) and Alarm
System.