341849-YIM-A-0108

18

Johnson Controls Unitary Products

FIGURE 7 - Typical Wiring Diagram Legend (See Pages 16 and 17)

FIGURE 8 - Typical Wiring Diagram Notes (See Pages 16 and 17)

CB
CCH
COMPR
DS
F1 F2 F3
F4 F5 F6
F7 F8 F9
F24
FS
HP
HTR 1
HTR 2
HTR 3
HTR 4
HTR 5
HTR 6
K1
K2
K3
K7
LP
LS
M1
M2
M3
PTCR
RC1/RC2
RC1
RC2
RC3
RVS
S2/P2
S3/P3
S4/P4
S3/P3
T1
TB2

CIRCUIT BREAKER 24V, 3 AMP
CRANKCASE HEATER (OPTIONAL)
COMPRESSOR
DEFROST SENSOR, CLOSES @ 31°F, OPENS @ 55°F.
FUSES, LINE VOLTAGE - 60 AMP (10, 15, 20 & 25 KW ELEC HEAT)
FUSES, LINE VOLTAGE - 30 AMP (10, 15, 20 & 25 KW ELEC HEAT)
FUSES, LINE VOLTAGE - 30 AMP (20, 25 KW ELEC HEAT)
FUSE 24V SECONDARY, 5 AMP
FREEZESTAT SWITCH (OPTIONAL ACCESSORY) OPEN @ 26° F
HIGH PRESSURE SWITCH (OPTIONAL ACCESSORY) OPENS @ 280 PSIG
ELECTRIC HEATER (OPT. ACCSSRY: ALL KW ELEC HEAT)
ELECTRIC HEATER (OPT. ACCSSRY: 7.5, 10, 15, 20 & 25 KW ELEC HEAT)
ELECTRIC HEATER (OPT. ACCSSRY: 20 & 25 KW ELEC HEAT)
ELECTRIC HEATER (OPT. ACCSSRY: 15, 20 & 25 KW ELEC HEAT)
ELECTRIC HEATER (OPT. ACCSSRY: 20 & 25 KW ELEC HEAT)
ELECTRIC HEATER (OPT. ACCSSRY: 20 & 25 KW ELEC HEAT)
RELAY INDOOR FAN MOTOR
RELAY ELECTRIC HEATER
RELAY ELECTRIC HEATER, 24 VDC COIL
RELAY LIMIT TRIP, 25 VDC COIL 
LOW PRESSURE SWITCH (OPTIONAL ACCESSORY) OPEN @ 7 PSIG
LIMIT SWITCH, ELECTRIC HEAT (PART OF ELEC HEAT ACCESSORY)
CONTACTOR, COMPRESSOR & OUTDOOR FAN
CONTACTOR, ELECTRIC HEAT, 230V COIL
CONTACTOR, ELECTRIC HEAT, 230V COIL
START ASSIST (OPTIONAL DEVICE)
COMPRESSOR START & OUTDOOR FAN RUN CAPACITOR
COMPRESSOR START CAPACITOR (ALTERNATE)
OUTDOOR FAN RUN CAPACITOR (ALTERNATE)
INDOOR FAN RUN CAPACITOR
REVERSING VALVE SOLENOID
SOCKET/PLUG CONNECTION ON FAN CONTROL BOARD, LOW VOLTAGE
SOCKET/PLUG CONNECTION ON FAN CONTROL BOARD, LINE VOLTAGE
SOCKET/PLUG CONNECTION ON ID FAN MOTOR, 24V
SOCKET/PLUG CONNECTION ON ID FAN MOTOR, 230V
TRANSFORMER, 24V, 40 VA
TERMINAL BLOCK ECM MOTOR "SPEED" CONNECTIONS
IDENTIFIED TERMINAL ON RUN CAPACITOR
ROOM THERMOSTAT 24V CONNECTIONS
TB1 ON FAN/ELEC HEAT CONTROL BOARD
 FACTORY WIRING AND DEVICES
OPTIONAL WIRING AND DEVICES
FIELD WIRING

7.  IF OPTIONAL SAFETY SWITCH KIT IS INSTALLED,

    WIRE 219/BK IS REMOVED.

8.  WIRE 204/BR IS REMOVED WHEN ELECTRIC HEAT

    IS INSTALLED.

9.  ELECTRIC HEAT ACCESSORY WITH DUAL POINT SUPPLY POWER.

    SEE DETAIL A

10. SHUNT CONTACT ALSO USED WITH CRANKCASE HEATER. (OPTIONAL)

6.  SELECT INDOOR BLOWER SPEED TO OBTAIN APPROX 400

    CFM/TON IN COOLING.

5.  SEE UNIT NAMEPLATE FOR MAXIMUM FUSE SIZE AND MINIMUM

    CIRCUIT AMPACITY.

4.  UNIT FACTORY WIRED FOR 230 VOLT OPERATION.  FOR 208 

    VOLT OPERATION MOVE '108/PR' WIRE FROM 240V TO 208V

    ON TRANSFORMER T1.

3.  MOTORS ARE INHERENTLY PROTECTED.

2.  CAUTION:  LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN

    SERVICING CONTROLS.  WIRING ERRORS CAN CAUSE IMPROPER

    AND DANGEROUS OPERATION.  IF ANY OF THE WIRE AS 

    SUPPLIED WITH THIS UNIT MUST BE REMOVED, IT MUST BE

    REPLACED WITH TYPE 105° C, 600V WIRE OR EQUIVALENT

    CLEARLY RENUMBERED FOR IDENTIFICATION.  VERIFY PROPER 

    OPERATION AFTER SERVICING.

1.  ALL FIELD WIRING TO BE ACCOMPLISHED FOLLOWING CITY,

    LOCAL AND/OR NATIONAL CODES IN EFFECT AT TIME OF

    INSTALLATION OF THIS UNIT.

Содержание B1HA036

Страница 1: ...ENT PARTS 3 PRODUCT NOMENCLATURE 3 INSTALLATION 4 SEQUENCE OF OPERATION 13 MAINTENANCE 15 See the following page for a complete Table of Contents NOTES CAUTIONS AND WARNINGS Installer should pay parti...

Страница 2: ...ND 575 3 60 POWER SUPPLY 17 7 TYPICAL WIRING DIAGRAM LEGEND 18 8 TYPICAL WIRING DIAGRAM NOTES 18 LIST OF TABLES Tbl Pg 1 UNIT APPLICATION DATA 4 2 UNIT DIMENSIONS 4 3 PHYSICAL DATA 6 4 ELECTRICAL DATA...

Страница 3: ...ormation on the design installation oper ation and service of this equipment is available in the following reference forms 341849 General Installation 035 16605 003 Electric Heater Accessory REPLACEME...

Страница 4: ...ain level tolerance of unit to 1 8 maximum RIGGING AND HANDLING Care must be exercised when moving the unit Do not remove any packaging until the unit is near the place of installation Rig unit with s...

Страница 5: ...ing compound on male pipe threads Install the condensate drain line 3 4 NPTF to spill into an open drain SERVICE ACCESS Access to all serviceable components is provided by the following removable pane...

Страница 6: ...heat CONTROL WIRING NOTE HEAT ANTICIPATOR SHOULD BE SET AT 0 25 AMPS FOR ALL MODELS PROGRAMMABLE THERMOSTAT ONLY REFER TO ELECTRICAL DATA TABLES TO SIZE THE DISCONNECT SWITCH WIRING OVERCURRENT PROTEC...

Страница 7: ...04501058 1 10 05 9 6 19 6 20 20 2NH04501558 1 15 05 14 4 25 6 30 30 042 575 3 60 5 8 44 0 0 4 1 5 2NH04501058 1 10 05 9 6 21 1 25 25 2NH04501558 1 15 05 14 4 27 2 30 30 048 575 3 60 5 6 44 0 0 6 1 6 2...

Страница 8: ...1097 604 1004 480 912 456 Medium 1465 631 1395 512 1325 492 1255 473 1167 446 1079 419 952 392 Low 1316 473 1260 455 1204 438 1148 420 1069 396 990 372 911 348 042 High 1728 725 1633 697 1527 666 142...

Страница 9: ...l under field conditions would be inaccurate To ensure a dry coil the compressors should be deac tivated while the test is being run 4 Knowing the pressure drop across a dry coil the actual CFM throug...

Страница 10: ...10 1 10 7 11 8 13 7 17 0 22 6 32 2 70 4 6 7 8 13 4 23 0 80 7 3 16 9 TABLE 11 Cooling Superheat at Compressor Suction Airflow 1 400 CFM B1HA042 Outdoor Temperature F Indoor WB Temperature F 55 57 59 6...

Страница 11: ...ompressor Suction F 10 0 10 20 30 40 50 60 55 8 3 8 4 8 6 9 0 10 1 12 4 17 4 28 6 70 4 2 9 2 20 4 80 5 7 16 9 TABLE 15 Cooling Superheat at Compressor Suction Airflow 2 000 CFM B1HA060 Outdoor Tempera...

Страница 12: ...UTDOOR COIL 15 4 BACK SIDE RETURN AIR OPENING SIDE SUPPLY AIR OPENING BOTTOM RETURN AIR OPENING 15 2 1 1 1 15 BOTTOM SUPPLY AIR OPENING 2 LOW VOLTAGE CONN DIA KNOCKOUT HIGH VOLTAGE CONN DIA KNOCKOUT F...

Страница 13: ...here is a call for heating by the thermostat 2 On a call for heating the thermostat will send 24 volts to Y on the fan control board After the anti short cycle period is complete the 24 volts signal w...

Страница 14: ...od the fan responds to thermostat input but the heaters are enabled This is to sense a failed heater relay The limit cycle count is reset at the start of a heat request If the limit remains open for p...

Страница 15: ...COIL Dirt should not be allowed to accu mulate on the outdoor coil surface or other parts in the air circuit Cleaning should be as often as necessary to keep the coil clean Use a brush vacuum cleaner...

Страница 16: ...ohnson Controls Unitary Products FIGURE 5 Typical Wiring Diagram 230 3 60 Power Supply M R C COMPR RELAY DFST STAT M1 DETAIL A 222 Y BLU BLU DS DEFROST CONTROL 031 01268 000B FOR DEFROST CONTROL 031 0...

Страница 17: ...341849 YIM A 0108 Johnson Controls Unitary Products 17 FIGURE 6 Typical Wiring Diagram BHA Models 460 3 60 and 575 3 60 Power Supply...

Страница 18: ...R FAN RUN CAPACITOR COMPRESSOR START CAPACITOR ALTERNATE OUTDOOR FAN RUN CAPACITOR ALTERNATE INDOOR FAN RUN CAPACITOR REVERSING VALVE SOLENOID SOCKET PLUG CONNECTION ON FAN CONTROL BOARD LOW VOLTAGE S...

Страница 19: ...341849 YIM A 0108 Johnson Controls Unitary Products 19...

Страница 20: ...hout notice Printed in U S A 341849 YIM A 0108 Copyright 2007 by Johnson Controls Inc All rights reserved Supersedes 66269 YIM A 0104 035 16004 002 A 0104 Johnson Controls Unitary Products 5005 York D...

Отзывы: