A11 Series Low Temperature Cutout Controls Product Bulletin

3

Ordering Information

Table 3 describes the A11 Series Low Temperature Cutout Control models. 

When ordering an A11 Series Low Temperature Cutout Control:

1.

Specify the product number.

2.

Specify the low temperature cutout stop setting, if necessary.

Repairs and Replacements

If the A11 Series Low Temperature Cutout Control fails to operate within its specifications, replace the unit. Contact 
your nearest Johnson Controls® representative.

Technical Specifications  

Table 3:  A11 Models

Model

Description

A11A

Single-Pole, Single-Throw (SPST), Open Low, Manual Reset

A11B

SPST, Open Low, Automatic Recycle

A11D

Single-Pole, Double Throw (SPDT), Manual Reset

A11E

SPDT, Automatic Recycle

A11 Low Temperature Cutout Controls

Product Codes

A11A: SPST, Open Low, Manual Reset
A11B: SPST, Open Low, Automatic Recycle
A11D: SPDT, Manual Reset
A11E: SPDT, Automatic Recycle

Range Cutout

35 to 45°F (2 to 7°C)

Differential

A11A and A11D

: Temperature must be 12°F (6.7°C) above cutout point before control can 

be reset.

A11B and A11E

: 12°F (6.7°C)

Ambient Temperature

Minimum:

 0°F (-18°C)

Maximum: 140°F (60°C)

Maximum Temperature at 
Bulb

250°F (121°C)

Sensing Element

1/8 in. x 20 ft (3.2 mm x 6.1 m) or 1/8 in. x 40 ft (3.2 mm x 12.2 m)

Capillary Length

4 ft (1.2 m)

Switch

Snap-acting contacts in dust-protected enclosure

Material

Case: 

0.6 (1.6 mm) Cold Rolled Steel

Cover:

 0.3 in. (0.8 mm) Cold Rolled Steel

Finish

Galvanized Steel

Conduit Opening

22 mm (0.9 in.) hole for 12.7 mm (1/2 in.) conduit

Mounting Bracket

Standard on all controls

Shipping Weight

Individual Pack:

 1.8 lb (0.8 kg)

Overpack of 20 Units:

 38 lb (17 kg)

Electrical Rating

Pilot Duty:

 125 VA, 24 to 277 VAC

Motor Ratings

AC Full Load Ampere:

 120 V = 16.0 A, 208 V = 9.2 A, 240 V = 8.0 A

AC Locked Rotor Ampere:

 120 V = 96.0 A, 208 V = 55.2 A, 240 V = 48.0 A

Non-Inductive Ampere: 

120 V = 16.0 A, 208 V = 9.2 A, 240 V = 8.0 A

Содержание A11A

Страница 1: ...om of the control and at the top of the control when the cover is removed Figure 1 A11 Series Low Temperature Cutout Control Table 1 Features and Benefits Features Benefits Precision Repeat Accuracy Remains unaffected by ambient temperature at the control diaphragm cup and 4 ft 1 2 m capillary 20 ft 6 1 m sensing bulb must be in the controlled area Trip Free Manual Reset Allows the lever to reset ...

Страница 2: ...igure 2 shows the A11 dimensions Figure 2 describes the A11 electrical ratings Table 2 Electrical Rating Motor Rating 120 V 208 V 240 V Motor Description AC Full Load Amperes 16 0 9 2 8 0 AC Locked Rotor Amperes 96 0 55 2 48 0 Non Inductive Amperes 16 0 9 2 8 0 Pilot Duty 125 VA 24 to 277 VAC 27 7 2 30 58 1 38 35 69 17 2 33 59 34 9 97 25 2 25 57 2 11 54 4 69 119 3 19 81 88 22 DIA 2 09 53 5 38 137 ...

Страница 3: ...Low Automatic Recycle A11D SPDT Manual Reset A11E SPDT Automatic Recycle Range Cutout 35 to 45 F 2 to 7 C Differential A11A and A11D Temperature must be 12 F 6 7 C above cutout point before control can be reset A11B and A11E 12 F 6 7 C Ambient Temperature Minimum 0 F 18 C Maximum 140 F 60 C Maximum Temperature at Bulb 250 F 121 C Sensing Element 1 8 in x 20 ft 3 2 mm x 6 1 m or 1 8 in x 40 ft 3 2 ...

Страница 4: ...g Technologies Solutions 507 E Michigan Street Milwaukee WI 53202 Compliance United States UL Listed File SA516 SDFY FCC Compliant to CFR 47 Part 15 Subpart B Class A Canada UL Listed CSA Class No 1222 01 File LR948 Industry Canada ICES 003 The performance specifications are nominal and conform to acceptable industry standards For application at conditions beyond these specifications consult the l...

Отзывы: