Johnson Controls Unitary Products

Physical Data

Table 1:

J07 thru 25YC and J10 thru 20YD Physical Data

Component

Models

J07YC

J10YC

J10YD

J12YC

J12YD

J15YC

J15YD

J20YC

J20YD

J25YC

Nominal Tonnage

7.5

10

10

12.5

12.5

15

15

20

20

25

REFRIGERANT

Refrigerant type

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

Holding charge (lb)

1

1. Holding Charge is the amount in the unit as shipped from the factory.

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

Operating Charge (lb)

2

2. Includes matched indoor blower unit with 25 ft. of piping.

System #1

14.0

18.0

9.9

24.0

11.5

27.0

13.5

33.5

18.8

35

System #2

---

---

9.9

---

11.5

---

13.5

---

18.8

---

DIMENSIONS (inches)

Length

59.1

59.1

59.1

59.1

59.1

59.1

59.1

59.1

59.1

59.1

Width

31.9

31.9

31.9

31.9

31.9

64.1

64.1

64.1

64.1

64.1

Height

44.5

50.0

50.0

50.0

50.0

44.5

44.5

50.0

50.0

50.0

WEIGHTS (lb)

Shipping

390

499

493

499

493

914

899

945

930

945

Operating

387

497

490

497

490

909

894

942

927

942

COMPRESSORS

3

3. All compressors include crankcase heaters.

Type

Single 

Scroll

Tandem 

Scroll

Single 

Scroll

Tandem 

Scroll

Single 

Scroll

Tandem 

Scroll

Single 

Scroll

Tandem 

Scroll

Single 

Scroll

Tandem 

Scroll

Quantity

1

1

2

1

2

1

2

1

2

1

Nominal Capacity (Tons)

System #1

7.5

10

5

12.5

6.3

15

7.5

20

10

25

System #2

---

---

5

---

6.3

---

7.5

---

10

---

Capacity Stages

System  #1

1

2

1

2

1

2

1

2

1

2

System #2

---

---

1

---

1

---

1

---

1

---

SYSTEM DATA

No. Refrigeration Circuits

1

1

2

1

2

1

2

1

2

1

Suction Line OD (in.)

1 1/8

1 3/8

1 1/8

1 3/8

1 1/8

1 5/8

1 3/8

1 5/8

1 3/8

1 5/8

Liquid Line OD (in.)

 5/8

 7/8

 5/8

 7/8

 5/8

 7/8

 5/8

 7/8

 5/8

7/8

OUTDOOR COIL DATA

Face area (Sq. Ft.)

23.8

29.0

29.0

29.0

29.0

47.5

47.5

58.1

58.1

58.1

Rows

1

1

1

1

1

1

1

1

1

1

Fins per inch

23

23

23

23

23

23

23

23

23

23

Tube diameter (in./MM)

0.71 / 18

0.71 / 18

0.71 / 18

0.71 / 18

0.71 / 18

0.71 / 18

0.71 / 18

0.71 / 18

0.71 / 18

0.71 / 18

Circuitry Type

2-pass

2-pass

2-pass

2-pass

2-pass

2-pass

2-pass

2-pass

2-pass

2-pass

Refrigerant Control

---

---

---

---

---

---

---

---

---

---

CONDENSER FAN DATA

No. Fans / Diameter (in.)

2/24

2/24

2/24

2/24

2/24

4/24

4/24

4/24

4/24

4/24

Type

Axial

Axial

Axial

Axial

Axial

Axial

Axial

Axial

Axial

Axial

Drive type

Direct

Direct

Direct

Direct

Direct

Direct

Direct

Direct

Direct

Direct

No. speeds

1

1

1

1

1

1

1

1

1

1

Number of motors

System  #1

2

2

2

2

2

4

2

4

2

4

System #2

---

---

---

---

---

---

2

---

2

---

Motor HP (ea.)

 1/3

 3/4

 3/4

 3/4

 3/4

 1/3

 1/3

 3/4

 3/4

 3/4

Rotation

4

4. When viewing the shaft end of the motor.

CW

CW

CW

CW

CW

CW

CW

CW

CW

CW

RPM

850

1100

1100

1100

1100

850

850

1100

1100

1100

Nominal CFM

System #1

7500

9800

9800

9800

9800

15000

7500

19600

9800

19600

System #2

---

---

---

---

---

---

7500

---

9800

---

Содержание J07 Thru 25YC

Страница 1: ...h J07YC Condenser Unit 13 4 Typical Field Wiring Diagram J10 thru J20NC Evaporator Unit with J10 thru J10YC Condenser Unit 14 5 J10 thru J20NC Liquid Line Solenoid Wiring 14 6 Typical Field Wiring Dia...

Страница 2: ...Style A Style A Y Split System Condenser AC R 410A AC Coil Guard AB Phase Monitor 2 Non Pwr d Conv Outlet 1 Disconnect T Options 1 5 S Options 5 D Options 1 2 C Option 2 B Option 1 Options 5 Pwr d Con...

Страница 3: ...d be noted on the carrier s freight bill A separate request for inspection by the carrier s agent should be made in writing Improper installation may create a condition where the operation of the prod...

Страница 4: ...croll Quantity 1 1 2 1 2 1 2 1 2 1 Nominal Capacity Tons System 1 7 5 10 5 12 5 6 3 15 7 5 20 10 25 System 2 5 6 3 7 5 10 Capacity Stages System 1 1 2 1 2 1 2 1 2 1 2 System 2 1 1 1 1 SYSTEM DATA No R...

Страница 5: ...chitect if the roof is bonded Choose a location with adequate structural strength to support the unit The condensing unit must be mounted on level supports The supports can be channel iron beams or wo...

Страница 6: ...jury Screws on access panels will prevent casual tampering Further safety precautions such as a fenced enclosure or locking devices on the panels may be advisable Check local authorities for safety re...

Страница 7: ...the largest dimension across the unit MUST be used across the top of the unit Units may be moved or lifted with a forklift Slotted openings in the base rails are provided for this purpose LENGTH OF F...

Страница 8: ...15 times as much water as other oils designed for HCFC and CFC refrigerants Take all necessary precautions to avoid exposure of the oil to the atmosphere POE polyolester compressor lubricants are know...

Страница 9: ...2 23 1 36 160 208 230 1 60 3 4 2 3 0 58 0 80 460 3 60 2 12 2 19 87 460 1 60 3 4 2 1 6 30 7 40 575 3 60 2 8 7 14 62 575 1 60 3 4 2 1 4 22 3 30 J15YC 208 230 3 60 2 25 0 39 164 208 230 1 60 1 3 4 2 1 6...

Страница 10: ...4 4 0 24 0 30 J12YC 208 230 3 60 2 22 4 35 149 208 230 1 60 3 4 2 3 0 10 0 66 5 80 460 3 60 2 10 6 17 75 460 1 60 3 4 2 1 6 5 0 32 1 40 575 3 60 2 7 7 12 54 575 1 60 3 4 2 1 4 4 0 24 0 30 J12YD 208 2...

Страница 11: ...tures must also be insulated Never solder suction and liquid lines together They can be taped together for convenience and support purposes but they must be completely insulated from each other The li...

Страница 12: ...disks the flow of Nitrogen will prevent any debris from entering the system Unbraze both liquid and suction sealing disks and prepare the joints for connections of the main lines Connect the main liqu...

Страница 13: ...tem 1 piping dimensions when applying a J07 10 12YC model system NOTE On non J NC ND Evaporator models isolation relays must be installed to avoid overloading on 75 VA transformers on the condensing u...

Страница 14: ...NC ND Evaporator models isolation relays must be installed to avoid overloading on 75 VA transformers on the condensing unit Figure 5 J10 thru J20NC Liquid Line Solenoid Wiring THERMOSTAT TWO STAGE C...

Страница 15: ...Unit with J10 thru J20YD Condenser Unit NOTE On non J NC ND Evaporator models isolation relays must be installed to avoid overloading on 75 VA transformers on the condensing unit THERMOSTAT TWO STAGE...

Страница 16: ...lays must be installed to avoid overloading on 75 VA transformer on the condensing unit Figure 8 J10 thru J20NC Liquid Line Solenoid Wiring NOTE Refer to Evaporator unit wiring diagram for control of...

Страница 17: ...orator Unit with Twin Condenser Units NOTE On non J NC ND Evaporator models isolation relays must be installed to avoid overloading on 75 VA transformers on the condensing unit R C Y2 G W1 THERMOSTAT...

Страница 18: ...rator Units with J15YD Condenser Unit NOTE On non J NC ND Evaporator models isolation relays must be installed to avoid overloading on 75 VA transformers on the condensing unit R C Y1 G W1 R C Y1 G W1...

Страница 19: ...ight Dimensions MODEL A J07YC 44 5 J10YC 50 0 J10YD 50 0 J12YC 50 0 J12YD 50 0 LEFT REAR RIGHT FRONT RIGHT 2X 0 875 KNOCKOUT 30 994 2X 1 375 KNOCKOUT CONVENIENCE OUTLET 7 000 10 000 24 000 31 758 7 00...

Страница 20: ...tem 1 piping dimensions when applying a J15 20 25YC model system LEFT RIGHT FRONT REAR FRONT FRONT PIPING DETAIL RIGHT SYSTEM 2 SYSTEM 1 7 000 7 000 23 000 37 000 64 000 2X 0 875 KNOCKOUT 2X 1 375 KNO...

Страница 21: ...tated manually to check for free rotation 4 Are all wiring connections tight 5 Does the available power supply agree with the nameplate data on the unit 6 Is the control circuit transformer set for th...

Страница 22: ...itch opens during normal operation the Simplicity control board will de energize the compressor initiate the ASCD and shut down the condenser fans On startup if the low pressure switch opens the Simpl...

Страница 23: ...rate the condenser unit When the thermostat calls for first stage cooling Y1 the Simplicity control board UCB closes the coils of relays RY1 and BR1 and contactor M1 Relay RY1 has three functions 1 co...

Страница 24: ...Off Off On On 4 Flashes Not Applicable 5 Flashes LPS1 Compressor Lockout Off Off On Off On 6 Flashes Not Applicable 7 Flashes FS1 Compressor Lockout2 2 Freeze Stat not applicable Off Off On On On 8 F...

Страница 25: ...ailure 1 Flash Not Applicable 2 Flashes Control waiting ASCD1 Flashing Off Off On Off 3 Flashes HPS1 Compressor Lockout Off Off Off On On 4 Flashes HPS2 Compressor Lockout Off Off On Off Off 5 Flashes...

Страница 26: ...E While in either Setup mode if no buttons are pushed for 60 seconds the display will revert to its normal display exiting the Option Setup mode When saving the control board only saves the parameters...

Страница 27: ...his chart is applicable to unit with the TXV s left to the factory setting If the TXV s have been adjusted in the field the charging chart may no longer apply Charging Curves J10YC 200 300 400 500 600...

Страница 28: ...his chart is applicable to unit with the TXV s left to the factory setting If the TXV s have been adjusted in the field the charging chart may no longer apply Charging Curves J12YC 200 300 400 500 600...

Страница 29: ...his chart is applicable to unit with the TXV s left to the factory setting If the TXV s have been adjusted in the field the charging chart may no longer apply Charging Curves J15YC 200 300 400 500 600...

Страница 30: ...his chart is applicable to unit with the TXV s left to the factory setting If the TXV s have been adjusted in the field the charging chart may no longer apply Charging Curves J20YC 200 300 400 500 600...

Страница 31: ...is chart is applicable to unit with the TXV s left to the factory setting If the TXV s have been adjusted in the field the charging chart may no longer apply 200 300 400 500 600 120 130 140 150 160 17...

Страница 32: ...430648 JIM D 1010 32 Johnson Controls Unitary Products Typical Wiring Diagrams Figure 25 Typical J07YC Condensing Unit Wiring Diagram...

Страница 33: ...430648 JIM D 1010 Johnson Controls Unitary Products 33 Figure 26 Typical J10 12YC Condensing Unit Wiring Diagram...

Страница 34: ...430648 JIM D 1010 34 Johnson Controls Unitary Products Figure 27 Typical J10 12YD Condensing Unit Wiring Diagram...

Страница 35: ...430648 JIM D 1010 Johnson Controls Unitary Products 35 Figure 28 Typical J15YC Condensing Unit Wiring Diagram...

Страница 36: ...430648 JIM D 1010 36 Johnson Controls Unitary Products Figure 29 Typical J15 20YD Condensing Unit Wiring Diagram...

Страница 37: ...430648 JIM D 1010 Johnson Controls Unitary Products 37 Figure 30 Typical J20YC Condensing Unit Wiring Diagram...

Страница 38: ...ed in U S A 430648 JIM D 1010 Copyright 2010 by Johnson Controls Inc All rights reserved Supersedes 430648 JIM C 0610 Johnson Controls Unitary Products 5005 York Drive Norman OK 73069 Figure 31 Typica...

Отзывы: