background image

Telephone: 01604 762881

2.8  INSTALLATION WITH AN INTEGRAL LE155/250 & 

LE155-1/250-1 HEAT RECOVERY UNIT

 

NOTE: Refer to the Installation, Commissioning and Servicing 
Instructions provided with the heat recovery unit and fit in the 
predetermined position above the cooker. DO NOT FIT the base plate to 
the heat recovery unit. This item is to be discarded!

 

2.8.1  Remove the grille from the cooker hood allowing access to the    
 

screw positions on the inside of the unit.

 

2.8.2  Using the screw positions where the base was fitted, fix the  

 

 

cooker hood.

 

2.8.3  Connect the cooker hood to the heat recovery unit in  

 

 

 

accordance with the heat recovery unit instructions.

 

2.8.4  Reconnect the grille to the cooker hood and close.

3.  COMMISSIONING

3.1 

Switch on the electrical supply to the unit.

3.2 

Switch on the heat recovery unit and ensure that air is being drawn 
through the cooker hood. (Measure airflow at the damper position with 
the grille removed.)

3.3 

Switch the lamp ON, to ensure that both lamps illuminate.

HR Unit Integral with 

Cooker Hood

Slim Line 

Cooker Hood

H

FIGURE 2

Cooker Hood Positioning

Отзывы: