Gas connection
The room containing the appliance should have an air
supply in accordance with B.S. 5440 part 2.
1. All rooms require an opening window or equivalent,
and some rooms will require a permanent vent as well.
2. For room volumes up to 5m³ an air vent of 100cm² is
required.
3. If the room has a door that opens directly to the
outside, and the room exceeds 1m³ no air vent is re-
quired.
4. For room volumes between 5m³ and 10m³ an air
vent of 50cm² is required.
5. If there are other fuel burning appliances in the
same room B.S. 5440 part 2 should be consulted to
determine the air vent requirements.
6. The appliance must not be installed in a bed sitting
room of less than 20m or in a bathroom or shower
room.
We recommend checking that the appliance is
properly set up for the type of gas distributed. The
threaded ½‰ gas connection pipe is located at the
rear on the right hand side of the appliance.
The cooker is designed to match the depth of standard
600mm worktops. An adaptor back plate should, the-
refore, be fitted within the shaded area shown to allow
the cooker to be pushed in fully and chased to the
wall.Connection to the cooker should be made with
an approved appliance flexible connection to BS 669.
A length of 0.9 to 1.25m is recommended. The length
of hose chosen should be such that when the cooker is
in situ, the hose does not touch the floor.The tempe-
rature rise of areas at the rear of the cooker that are
likely to come in contact with the flexible hose do not
exceed 70°C.