Conversion from natural gas to LPG
Unscrew the adjustment screw Z to increa-
se the flow, or tighten it to reduce the flow.
The adjustment is correct when the low
flame measures approximately 3 or 4 mm.
When changing quickly from maximum to
minimum flow and vice versa make sure
that the flame does not go out.
It is important to note that this model is designed
for use with natural gas but can be converted for
use with butane or propane gas (conversion kit
included) providing the correct injectors are fitted.
The gas rate is adjusted to suit.
Proceed as follows:
• Remove the pan supports;
• Remove the burners and burner caps (Fig. A);
• Take out the injector (Fig. B) and replace it with
one suitable for the new type of gas (see „Gene-
ral injectors table‰);
• Replace the gas label (on the rear of the ap-
pliance) with the new one provided with the
injectors kit;
• Refit all parts by following the disassembly
instructions in reverse order and taking care to
position the burner cap correctly on the burner.
Minimum flow of valved cooking
hob taps
• Switch on the burner and turn the control knob
towards the minimum flow position ;
• Remove the knob;
• Using a screwdriver, adjust the internal screw Z
until the correct low flame is obtained;
• Refit the knob.
Minimum flow of non-valved
cooking hob taps
• Switch on the burner and turn the control knob
towards the minimum flow position ;
• Remove the knob;
• Insert a small screwdriver into the rod of the tap
and adjust the internal screw Z until the correct
low flame is obtained;
• Refit the knob.
12
Connecting to LPG
Use a pressure regulator and connect to the
cylinder in compliance with the guidelines set out
in standards regulations in force.
L.P.G. cookers MUST NOT be installed
below ground level i.e. in a basement or
aboard any boat, yacht or other vessel.
General injectors table
TYPE OF GAS
mBar
INJECTOR NO.
BURNERS
POSITION TYPE
POWER Watts
MAX.
CONSUMPTION
INJECTOR
BY-PASS
MAX
MIN
NATURAL
GAS
G20 (E)
20
127
39 GAP
RAPID
3000
500
286 l/h
97
29 GAP
SEMI-RAPID
1750
350
167 l/h
77
27 GAP
SIMMER
1000
290
95 l/h
136
65 GAP
TRIPLE RING
3900
1500
371 l/h
LPG
BUTANE
PROPANE
G30/G31
28-30/37
85
39 GAP
RAPID
3000
500
219 g/h
65
29 GAP
SEMI-RAPID
1750
350
128 g/h
50
27 GAP
SIMMER
1000
290
73 g/h
100
65GAP
TRIPLE RING
3900
1500
284 g/h
Содержание JLFSMFC 601
Страница 1: ...JLFSMFC 601 Multifunction Cooker Instruction manual ...
Страница 23: ...NOTES ...