dCSS/dSCR Multiswitch (Ref. 9733PL & 9734PL) v1.0 

 

 

 

 

 

2

 

 

 

 

 

C

ONTENTS

 

1.

 

I

NSTALLATION OF THE HARDWARE

 ...................................................... 3

 

1.1.

 

Quattro LNB ............................................................................................ 3

 

1.2.

 

Wideband LNB’s ....................................................................................... 4

 

2.

 

C

ONFIGURATION OF THE MODULE

 ........................................................ 5

 

2.1.

 

Input : Quattro versus Wideband ............................................................... 5

 

2.2.

 

Output: Legacy versus dSCR ..................................................................... 7

 

EN50494/SCR standard (DiSEqC 1.0) ......................................................... 7

 

EN50607/dCSS/dSCR standard (DiSEqC 2.0) .............................................. 7

 

CONCURRENT EN50494/EN50607 standards ............................................... 7

 

2.3.

 

DC Power................................................................................................ 8

 

3.

 

T

ECHNICAL 

S

PECIFICATIONS

 ............................................................. 9

 

4.

 

S

AFETY 

I

NSTRUCTIONS

 .................................................................. 11

 

5.

 

C

ONDITIONS OF WARRANTY

 ............................................................. 12

 

 

 

 

 

 

 

 

 

No part of this manual may be copied, reproduced, transmitted, transcribed or translated into any language 

without permission. 

Unitron reserves the right to change the specifications of the hardware and software described in these manuals 

at any time. 

Unitron cannot be held liable for any damages resulting from the use of this product. Specifications 
are subject to change without notice. 2/17 

©

 

 Unitron - Frankrijklaan 27 - B-8970 Poperinge - Belgium 

T +32 57 33 33 63 F +32 57 33 45 24 

email [email protected] 

www.unitrongroup.com 

 

 

Содержание 9733PL

Страница 1: ...User Manual dCSS dSCR Multiswitch 9733PL 9734PL ...

Страница 2: ...ONS 9 4 SAFETY INSTRUCTIONS 11 5 CONDITIONS OF WARRANTY 12 No part of this manual may be copied reproduced transmitted transcribed or translated into any language without permission Unitron reserves the right to change the specifications of the hardware and software described in these manuals at any time Unitron cannot be held liable for any damages resulting from the use of this product Specifica...

Страница 3: ...dCSS dSCR Multiswitch Ref 9733PL 9734PL v1 0 3 1 INSTALLATION OF THE HARDWARE 1 1 Quattro LNB ...

Страница 4: ...dCSS dSCR Multiswitch Ref 9733PL 9734PL v1 0 4 1 2 Wideband LNB s ...

Страница 5: ...al setup In this mode a quad LNB can also be used but then an extra product will need to set the 4 polarities of the LNB to match the VL HL VH HH inputs of the 9733PL 9734PL This can be done by using the Johansson ref 9930 When using wideband LNBs the switch on each 9733PL 9734PL should be set in the lower position Wideband LNB In this case wideband satellite signals from 290 to 2340MHz should be ...

Страница 6: ...The diagram above shows the basic frequency relation between wideband satellite frequencies and the standard legacy satellite frequencies Below is the relation between the STB tuned transponder and the wideband incoming transponder frequency In both the Quattro and Wideband mode the 9733PL 9734PL will allow powering the LNBs on both vertical trunks lines see chapter 2 3 DC Power for more details o...

Страница 7: ...nds UB1 UB25 for 9733PL and UB1 UB16 for 9734PL This is typically for new multi tuner STBs CONCURRENT EN50494 EN50607 standards For upgrading existing SCR installations where the main STB is upgraded to Next Gen PVR the dSCR multiswitch can support both standards simultaneously In this case a mix of STBs can be supported The existing STBs will use UB1 through UB8 The new main STB will use UB1 thro...

Страница 8: ... power from the trunklines Adding DC on trunks can be done by using a power insertor Ref 9669 and a powersupply Ref 2460 on 1 of the vertical trunk lines See chapter 1 on hardware installation for a typical example This setup will also power the LNB and the trunk amplifiers A powersupply Ref 2460 is designed to power up to 6 of these dSCR multiswitches in cascade When connecting more than 6 dSCR m...

Страница 9: ...S dSCR UBs 25 16 16 dCSS dSCR output level 85 dBµV Return loss 8 dB Typ 12 dB Tap loss Not applicable AGC automatic Gain control Terrestrial Cable loss 7 dB 11 dB Band and polarity selection Universal LNB voltage Tone DiSEqC 1 0 unidirectional DiSEqC 2 0 bidirectional Standard EN 50494 SCD Standard EN 50607 SCD 2 Max DC current consumption 320mA 13 Volt 350mA 13 Volt Power supply From STB power in...

Страница 10: ...420 2 1420 3 1680 3 1680 3 1680 3 1680 4 2040 4 2040 4 2040 4 2040 5 978 5 978 5 978 5 978 6 1028 6 1028 6 1028 6 1028 7 1072 7 1072 7 1072 7 1072 8 1116 8 1116 8 1116 8 1116 9 1160 9 1160 10 1271 10 1271 11 1315 11 1315 12 1359 12 1359 13 1484 13 1484 14 1528 14 1528 15 1572 15 1572 16 1616 16 1616 17 2084 18 2128 19 1816 20 1860 21 1904 22 1948 23 1992 24 1728 25 1772 ...

Страница 11: ...entilation Do not place any items such as newspapers table cloths curtains on the unit that might cover the ventilation holes Do not place any naked flame sources such as lighted candles on the apparatus Do not install the product in a dusty place Use the apparatus only in moderate climates not in tropical climates Respect the minimum and maximum temperature specifications To avoid any risk of ele...

Страница 12: ... its specifications Installation or use in a manner inconsistent with the technical or safety standards in force in the country where the product is used Use of non suitable accessories power supply adapters Installation in a defect system External cause beyond the control of Unitron N V such as drop accidents lightning water fire improper ventilation THE WARRANTY IS NOT APPLIED IF Production date ...

Отзывы: