background image

 

 

33

 

Control changes (recognized) 

Controller 7 (07h) 

General volume, with volume values 0 (00h) –

 

    127 

(7Fh). 

Controller 11 (0Bh) 

 Expression pedals, with volume values 0 (00Fh) –

 

    127 

(7Fh). 

 

Program changes (transmitted/recognized) 

Organ stops: Depends on the number of stops and the sequence of stops.

 

MIDI stops (programmable): 1-128.

 

 

System exclusive messages (transmitted/recognized) 

Each ‘sys ex’ (system exclusive) message largely looks the same. The first 
7 bytes and the last byte are always the same. Only the value of the 8th 
byte varies. This is the 

sys ex message

 that Johannus generally uses: F0 

00 4A 4F 48 41 53 XX F7 (hexadecimal). The ‘sys ex messages’ 
described below only indicates the value of the 8th byte (XX) and the 
output from which it is transmitted.

 

 

All stops off 

The ‘all stops off’ sys ex code is 7F. This sys ex code is transmitted 
through the MIDI SEQ. output when the 0 piston is pressed for a long time. 
When an ‘all stops off’ sys ex code is received, all stops on the instrument 
are switched off.

 

 

Pushbutton values 

When a piston is pressed, a sys ex code is transmitted with the value of 
the piston that is pressed (for example PP = 00 P = 01) through the MIDI 
MOD. output. 
These sys ex codes are only important when the Johannus sound module 
CSM 128 is connected to your instrument. 

 

Other MIDI codes (transmitted) 

Press the 0 piston to transmit the sys ex code, ‘all stops off’ and all volume 
settings through the MIDI SEQ. output. 

 
Sys ex code stops (Program Changes) 

When a MIDI stop is switched on and off, an extra Program Change code 
(preceded by the sys ex code 3F) is transmitted through the MIDI SEQ. 
output, besides the usual Program Change. This is to distinguish between 
a ‘normal’ organ stop and a MIDI stop before transmitting a module.

 

When a stop is switched on and off, the following codes are transmitted: 
 
Organ stop: 

 

Through MIDI SEQ.: CB XX

 

MIDI stop: 

 

Through MIDI MOD.: CX XX.

 

Through MIDI SEQ.: CB XX and 3F CX XX 

Содержание Vivaldi 15

Страница 1: ...User Manual User Manual...

Страница 2: ...us com Website www johannus com Version 2 0 Date May 2009 2009 Johannus Orgelbouw b v All rights reserved Nothing in this publication may be reproduced stored in a data file or made public in any form...

Страница 3: ...ntrols 14 4 2 Expression pedals 14 4 3 Acoustics Adaptive Surround Reverb ASR 12 14 4 4 Intonations 15 4 5 Factory intonation 15 4 6 Super Solos Orchestrals 16 4 7 Stops 16 4 8 Couplers 16 4 9 Accesso...

Страница 4: ...ANTY 29 5 1 Maintenance 29 5 1 1 Cabinet maintenance 29 5 1 2 Maintenance of the manuals 29 5 2 Problems 29 5 2 1 Reposition the pedal 30 5 3 Warranty 30 6 MIDI IMPLEMENTATIONS 31 6 1 MIDI Implementat...

Страница 5: ...tructions and precautionary measures in this user manual Keep this user manual with the organ The organ may only be opened by a technician authorised by Johannus Orgelbouw b v The organ contains stati...

Страница 6: ...et the organ upright 5 Put the music desk E in the groove on the cover of the organ 6 Place the organ bench over the pedal 7 Make sure the voltage of the organ matches the voltage of the mains See the...

Страница 7: ...d the pedalboard from the organ Relative humidity within the storage area 10 to 90 2 4 Open and close the rolltop cover The organ can be closed with a wooden rolltop cover that has a lock The rolltop...

Страница 8: ...nents Vivaldi 15 Vivaldi 25 A Rolltop cover B Rolltop cover lock C Music desk Vivaldi 15 C Music desk with tweeters Vivaldi 25 C Music desk with tweeters Vivaldi 35 D Loudspeakers E General Crescendo...

Страница 9: ...Subgroup intonations P Chorus Manual Bass Cantus Firmus Fix Accessories E Super Solos Q Reeds Off accessory F Swell stops tremulant and Midi R 0 reset piston G Manual Swell S Pre programmed memory loc...

Страница 10: ...Firmus Fix Accessories E Super Solos Q Reeds Off accessory F Swell stops R 0 reset piston G Manual Swell S Pre programmed memory locations H Manual Great T Sequence Sequence I On off U Capture memory...

Страница 11: ...group intonations R MENU G Subgroup intonations S General Crescendo H Rolltop cover lock T and pistons I Super Solos U Transposer J Swell stops V Chorus Manual Bass Cantus Firmus Fix Accessories K Man...

Страница 12: ...ory to the organ 3 Switch the accessory on 4 Switch on the organ 3 4 External connections The external connections are on the left under the console MIDI IN This is an input for receiving MIDI codes f...

Страница 13: ...the external device is controlled by means of MIDI codes through the MIDI MOD connection of the instrument AUX OUT This is an output for connecting an external stereo amplifier EXT REV This is an outp...

Страница 14: ...effect This effect provides a spatial reproduction of the organ sound that can be adjusted continuously Turn the volume control to adjust the reverb volume The reverb length can be set using the Easy...

Страница 15: ...elected automatically 4 5 Factory intonation Saving the intonation settings You require the Johannus intonation program to save the intonation settings 1 Connect a PC to the organ Use the MIDI SEQ out...

Страница 16: ...ed stop is active The stops are divided into four groups Pedal Activates the stops associated with the Pedal Vivaldi 15 25 35 Choir Selects the stops controlled by the Choir stops Vivaldi 35 Great Act...

Страница 17: ...mping Cantus Firmus CF Couples the Swell monophone to the Great Only the highest tone played on the Swell is coupled to the Great Use the CF piston to activate the Cantus Firmus If only the highest to...

Страница 18: ...ys A short press on the 0 piston Only the last change is cancelled A long press on the 0 piston All registrations are cancelled 4 11 Pre programmed memory locations Pre programmed memory locations are...

Страница 19: ...l 1 16 on the display 3 Press the SET piston Hold in the piston 4 Press the desired memory location 1 8 5 Release the SET piston Calling up a capture memory location 1 Use the and pistons to select th...

Страница 20: ...ry quiet pianissimo to very loud tutti Activate the General Crescendo pedal When the General Crescendo pedal is not activated the CR message is on the display 1 Press the CR piston to activate the Gen...

Страница 21: ...2 Use the and pistons to select the Super Solos or Orchestrals function on the display 3 Press the SET piston The display shows the Clarinet Vivaldi 15 or the Strings Vivaldi 25 35 and the manual on w...

Страница 22: ...ice number Vc 7 Press the SET piston The selected adjustments are now stored in memory 8 Select another MIDI stop to be programmed if desired 9 Press the MENU piston to return to the main menu 10 Pres...

Страница 23: ...sets the operation of the keys This function is not available for organs with wooden keyboards 1 Press the MENU piston 2 Use the and pistons to select the Keyboard Config function on the display 3 Pre...

Страница 24: ...gth and Program 5 Press the SET piston The display requests confirmation 6 Use the and pistons to select No or Yes 7 Press the SET piston for confirmation 8 Press the MENU piston to return to the main...

Страница 25: ...ard intonation in the memory 1 Press the MENU piston 2 Use the and pistons to select the Startup Settings function 3 Press the SET piston The display shows the set intonation 4 Use the and pistons to...

Страница 26: ...to produce a clearer and more transparent sound Select On for an extra addition to the reverberation to produce a fuller sound 10 Press the SET piston The selected 3D Surround setting is stored in the...

Страница 27: ...ation to the factory setting 1 Switch off all stops 2 Select an intonation 3 Press the MENU piston 4 Use the and pistons to select the Key Volumes function on the display 5 Press the SET piston 6 Use...

Страница 28: ...gain to exit the Easy Menu 4 15 13 Tweeter Settings Vivaldi 25 35 The Tweeter function is used to turn the tweeters on or off and to adjust the volume of the tweeters 1 Use the ROM SYM BAR HIST piston...

Страница 29: ...leaning agents such as paint thinner or acetone to remove dirt 1 Clean the manuals with a damp cloth 2 Rub the manuals dry with a lint free cloth 3 Remove any scratches with car polish 5 2 Problems Ov...

Страница 30: ...he pedalboard 4 Set the organ upright 5 Make sure the pedalboard works properly 6 Contact your dealer if the pedalboard does not work properly 5 3 Warranty The conditions are specified in the warranty...

Страница 31: ...H v Velocity ON Velocity OFF irrelevant After Touch Keys Channels N N Pitch Bend N Control Change 7 11 100 101 6 100 101 6 Y Y Y Y General Volume Expr pedals Pitch Transposer Program Change True See M...

Страница 32: ...changes transmitted Can be programmed through the MIDI program Control changes transmitted Controller 7 07h General volume with volume values 40 28h 127 7Fh Controller 11 0Bh Expression pedals with v...

Страница 33: ...when the 0 piston is pressed for a long time When an all stops off sys ex code is received all stops on the instrument are switched off Pushbutton values When a piston is pressed a sys ex code is tran...

Отзывы: