Joerns Arise LAL 1000 Скачать руководство пользователя страница 7

Arise LAL

®

 Mattress and Overlay

Twenty (80") or twenty one (84") individual 
therapy cells help to evenly distribute the 
patient’s weight and maximize pressure relief. 
Modular cell design mattress for ease of 
cleaning, re-assembly and cost effective service.
Lower two-inch support cell provides support in 
the event of a power failure.
6.5" deep mattress therapy cells and 5" deep 
overlay therapy cells are constructed of highly 
durable, polyurethane coated nylon to provide 
adequate support and prevent bottoming out for 
most patients within weight limit.
Integrated low-pressure heel section provides 
lower interface pressures
Durable base tub is constructed from 100% 
heavy weight 1680 denier nylon with a 1.5 
oz. urethane coating and incorporates bed 
attachment loops for stability.
Maximum weight capacity: Up to 500 lbs. based 
on model*

Anti-kink, easy clean air supply hose set
Integrated CairRails risk management side 

both sides of the patient along the mattress edge 
to provide additional support and to provide a 
gentle reminder to the patient that they are near 
the edge of the mattress. Constructed with lower 
ingress/egress area.

Arise LAL 1000 Mattress

Twenty individual therapy cells help to evenly 
distribute the patient’s weight and maximize 
pressure relief. Modular cell design mattress  
for ease of cleaning, re-assembly and cost 
effective service. 
Lower two-inch therapy support cell provides 
additional therapeutic support and remains 

power failure.
6.5" deep therapy cells are constructed of highly 
durable, polyurethane coated nylon to provide 
adequate support and prevent “bottoming out” 
for most patients within weight limit.
Integrated low-pressure heel section provides 
lower interface pressures
Durable base tub is constructed from 100% 
heavy weight 1680 denier nylon with a 1.5 
oz. urethane coating and incorporates bed 
attachment loops for stability.

Maximum weight capacity: 1000 lbs.*

patient’s weight and body shape.
Anti-kink, easy clean air supply hose set
Integrated CairRails risk management side 

both sides of the patient along the mattress 
edge to provide additional support and to 
provide a gentle reminder to the patient 
that they are near the edge of the mattress. 
Constructed with lower ingress/egress area. 

Arise LAL 1000 EX Mattress

Caregiver operated mattress control panel to 
adjust the following mattress features:

 

-

of the 6” wide side bolsters (left and right) 
when used in combination with the Joerns 
Bari10A bed (36, 42 or 48 inches wide) 
allows for close-in nursing procedures that 
may other wise be a strain on the care 
giver and transportation through 
narrow doorways.

 

-

 

-

extension cells which in combination with 
the Joerns

®

 Bari10A bed allow the bed and 

mattress to extend from 80 to 88 inches  
in length.

Sixteen (Eight paired) individual therapy cells 
help to evenly distribute the patient’s weight 
and maximize pressure relief. Modular cell 
design mattress for ease of cleaning, 
re-assembly and cost effective service.
Lower three-inch foam support cell provides 
additional therapeutic support and remains 
supportive in the event of a power failure or for 
patient transport.
Five-inch deep therapy cells are constructed 
of highly durable, polyurethane coated nylon 
to provide adequate support and prevent 
bottoming out for most patients within the 
weight limit.
Maximum weight capacity: 1000 lbs.*

*  Mattress weight capacity only; total weight must not 

Electronic Copy: Reference Only

Notice: Document considered current at time of printing. Verify revision before use. 

Содержание Arise LAL 1000

Страница 1: ...To avoid injury read user s manual before using Electronic Copy Reference Only Notice Document considered current at time of printing Verify revision before use...

Страница 2: ...properly within the protrude over the side or between the bed rails when the mattress is being used Danger Explosion Hazard Do not use in the in the presence of smoking materials or open support combu...

Страница 3: ...uidelines intended to reduce the risk of entrapment including dimensional limits for critical gaps and spaces between bed system components and clinical guidance for assessment and implementation of b...

Страница 4: ...Power Failure CairRails Optional Accessories Troubleshooting 13 Unable to Change Therapy Mode or Adjust Comfort Control Nursing Procedures 13 14 Recommended Linen Changing the Therapy Pad Patient Pos...

Страница 5: ...ssure relief by combining low air loss with pulsation Low air loss therapy has been demonstrated to reduce the risk of pressure ulcers as well as being a valuable aid in the treatment of pressure ulce...

Страница 6: ...for these patients should be considered on an individual basis and discussed with the attending physician The Arise LAL is comprised of two components Therapy control unit Therapy mattress system per...

Страница 7: ...ed low pressure heel section provides lower interface pressures Durable base tub is constructed from 100 heavy weight 1680 denier nylon with a 1 5 oz urethane coating and incorporates bed attachment l...

Страница 8: ...poor installation of a ground wire that causes the loss of proper ground at the outlet Inadequate grounding at electrical outlets can occur even if there is a ground wire Wires can become loose over t...

Страница 9: ...eat section securely to the sleep deck of the bed frame If the therapy pad is not already on the overlay attach it securely using the zippers Hang the control unit on the foot of the bed facing away f...

Страница 10: ...setting Refer to Comfort Adjust Setup section Figure 2 on the lower right of the control CairRails by moving the control knob to the up If the patient needs the extended width functionality of the be...

Страница 11: ...d Pulsate Static The unit starts in the Static mode which is the standard low air loss therapy Pulsate Pulsate will slightly decrease the pressure in all cushions every 30 seconds then return to the p...

Страница 12: ...nd visual alarm Power Interruption Brown out In the event of a brief power interruption up to twenty 20 minutes the Arise LAL control unit will automatically restart and reset to the previous Comfort...

Страница 13: ...ly Special linens are not necessary for the Arise LAL While there is no need for a bottom sheet the therapy pad should be covering the therapy cells at all times The patient should never be lying dire...

Страница 14: ...should always be in the lowest practical position when the patient is unattended Make sure areas under and around the frame are clear of objects persons and parts of body before adjusting height Warni...

Страница 15: ...y pad can be laundered in a washer and dryer with warm water no more than 120 Fahrenheit A non bleach detergent should be used sparingly Wipe dry or allow to air dry Do not use any steam cleaning devi...

Страница 16: ...LAL 1000 Mattress 48 122 cm W 80 203 cm H 8 5 22 cm D Arise LAL 1000EX Mattress 36 42 48 91 107 122 cm W 80 88 203 224 cm L 8 5 22cm D USA 120V AC 60 Hz 4A less than 1A running Operating Conditions A...

Страница 17: ...Electronic Copy Reference Only Notice Document considered current at time of printing Verify revision before use...

Страница 18: ...e instructions is not covered Joerns Arise LAL contains various parts that wear from normal use Joerns Healthcare s obligation under it s warranty is limited to supplying replacement parts servicing o...

Отзывы: