background image

2

Important Precautions

WARNING: POSSIBLE INJURY OR DEATH. 

This product is intended for use as an

adjustable mattress platform that articulates for patient comfort, and adjusts in height for patient
and caregiver convenience. Use of this product in a way it was not designed for could result in an

unproven or unsafe configuration, potentially resulting in injury or death. 

WARNING: POSSIBLE INJURY. 

Before adjusting bed, check that the area under and near

the perimeter of the bed is free of people and obstructions. Failure to do so could result in injury.

WARNING: POSSIBLE INJURY.

Keep bed in lowest position except for providing care

(bathing, clothing changes, etc.). Bed should be at the lowest convenient height for entry or exit.

Failure to do so could result in injury.

WARNING: POSSIBLE INJURY OR DEATH.

Floor locks increase bed stability and

resident safety. Make sure any floor/caster locks are engaged before attempting any resident
transfers. Failure to do so could result in injury or death.

WARNING: POSSIBLE INJURY OR DEATH. 

Residents may become entangled in the

pendant cord. Those residents with reduced mental acuity should not be allowed access to the

pendant. Failure to do so could result in injury or death.

WARNING: POSSIBLE INJURY OR DEATH.

Bed weight capacity is 500 pounds evenly

distributed. This is the total weight of the resident, mattress, bedding and any other equipment or
persons likely to be on the bed. Do not exceed the 500 pound capacity, or use water mattresses

that allow water to flow to the end of the bed when the head or foot sections are articulated.
Failure to do so could result in injury or death.

WARNING: POSSIBLE INJURY OR DEATH.

Do not roll bed over abrupt thresholds

with resident in bed. Damage to the caster system may occur causing the bed to stop suddenly.
Failure to do so could result in injury or death.

WARNING: POSSIBLE FIRE HAZARD. 

Use nasal mask or ½ bed tent oxygen

administering equipment. Oxygen tent should not extend below mattress deck. Pendant should not
be placed in an oxygen enriched environment such as an oxygen tent. Failure to do so could result
in a fire hazard.

WARNING: POSSIBLE SHOCK HAZARD.

Unplug power cord from wall outlet before

performing any maintenance, cleaning, or service to the bed. Failure to do so could result in injury
or death.

WARNING: POSSIBLE SHOCK HAZARD.

Injury may result from improper routing of

the power cord. Always follow the proper factory-installed routing configuration. Failure to do so

could result in injury or death.

WARNING: POSSIBLE INJURY OR DEATH.

Use a mattress that is properly sized to fit

the mattress deck and will remain centered on the mattress deck relative to State and Federal
guidelines. Sunrise Medical recommends the use of a mattress with minimum dimensions of 35” in
width, 6” in height, and length to match the mattress deck. Failure to do so could result in injury or

death.

Содержание Easy Care 2003DC

Страница 1: ...User Service Manual for Joerns Easy Care 2003DC Model B684DC To avoid injury read user s manual before using bed...

Страница 2: ...esident mattress bedding and any other equipment or persons likely to be on the bed Do not exceed the 500 pound capacity or use water mattresses that allow water to flow to the end of the bed when the...

Страница 3: ...will allow a resident to get his or her head or neck lodged within these openings Failure to do so could result in injury or death WARNING POSSIBLE INJURY OR DEATH Do not use any Joerns assist device...

Страница 4: ...regulatory guidelines can be complex That s why Joerns offers a wide array of compliance options We will assist customers in selecting compliant accessories recommended for their model beds Creating a...

Страница 5: ...ds distributed evenly on the sleep surface and a normal working load of 300 pounds This is the total weight of the resident mattress bedding accessories and other medical equipment in use Do not use w...

Страница 6: ...sticker side up four holes should be visible The foot panel brackets are the shorter of the two sizes fig 4 Install the foot panel brackets with the four long screws provided The open side of the brac...

Страница 7: ...inate surfaces should be maintained by cleaning with a disinfectant spray Head Operation 1 Push button to raise Head 2 Push button to lower Head Knee Operation 3 Push button to raise Knee 4 Push butto...

Страница 8: ...l cords are plugged in including pendant staff control cords and AC Power 2 There is a protection feature built into the motors and control box to prevent overheating If the bed was operating continuo...

Страница 9: ...e gap between the mattress and the head foot board is small enough to prevent a resident from getting his or her head or neck caught in these locations Failure to do so could result in injury or death...

Страница 10: ...ay cause it to disconnect from the bed resulting in a loss of control of the bed 4 Extra care should be taken when moving the bed on any slope Moving the bed on a slope requires two people one at each...

Страница 11: ...harger Green light indicates main power is ON Yellow light indicates battery is charging After approximately 4 hours of charging the yellow light goes off and the battery will be fully charged To Powe...

Страница 12: ...dical will void this warranty Parts Joerns beds contain various parts that wear from normal use These parts such as DC batteries are not covered under the 2 year warranty but are covered for 90 days a...