6
Pre-heating setting is in the “Power off” status and the LCD display
“
---
”。
1
、
Press
“
HEAT
”,
and enter to Pre-heating setting status, and the LCD flashes of “ON OFF”.
2
、
Press
“
OPEN
”,
can turn on the pre-heating setting ( by opposite, if press
“
CLOSE
”
, it will turn off the
pre-heating)
,
and at this time,
“
ONOFF
”
on LCD will turn to “ON
”,
and will not flash
(
if press
“
CLOSE
”
to turn off pre-heating
,
LCD will display
“
OFF
”
which do not flash there
)
。
When the system enter into time
setting of pre-heating, the setting time will flash on the LCD (this time is the pre-heating time which will start)
,
at this moment, only
“
MIN
”
and
“
HOUR
”
are available to change the time
。
It will add 1 minute when pressing
“
MIN
”
each time and the minutes could be added the continually
when pressing the
“
MIN
”
without stop
。
The adjustment range is 0~59
。
It will add 1 hour when pressing
“
HOUR
”
each time
,
and the hours could be added the continually when
pressing the
“
HOUR
”
without stop
。
The adjustment range is
AM 0~PM 11
。
And after time setting of pre-heating
,
you could go on to next step
。
3
、
Press
“
SET
VOL+
”
to continual time setting of pre-heating
,
it will show the minimum continue time is 10
minutes on the LCD
,
and this time will not flash
。
It will add 10 minutes by pressing
“
MIN
”
each time
,
and it will add 1 hour when pressing
“
HOUR
”
each time
,
please note that the maximum of continual time
is 19 hours and 50 minutes
。
When you set up well of the continual time
,
you could go on to the next step
。
4
、
Press
“
SET
VOL+
”
again to the temperature setting of pre-heating
。
It will show
“
SET
”
label on the LCD
panel
,
press
“
TEMP
”
and button could change the temperature setting. The range of temperature
setting is 25~45
℃。
5
、
When everything is setting well
,
Press
“
HEAT
”
again
,
the system will quit the pre-heating setting status
。
***
Notice
***
1
、
all setting of pre-heating must be in Power OFF status, just connect the spa with
the power supply. and the LCD display
“
---
”。
2
、
please note that it shows "on" or "off" on the LCD, "on" means pre-heating is
turn on, when the time of pre-heating is the same as currently time, the heater
will start working. "off" means the heater can't start-up anytime
。
3
、
Circulation PUMP and HEATER are not working while all setting time
。
(6) Pre-heating
:
When the time of real time and pre-heating time is consistent
,
meanwhile
,
there is water in the bathtub
and the pre-heating button is
“
on
”
,
the system will start the pre-heating and circulation pump and auto-constant
temperature system will work at the same time
。
Then LCD will show count down time
(
the two middle spot will
not flash any longer
)
and corresponding working status
。
In the pre-heating process
,
till cont down time
finished
。
the pre-heating will be turned off automatically by system or by pressing the
“
HEAT
”
or
Содержание SPA-308
Страница 1: ...1 OUTDOOR SPA SPA 308 PROGRAMMING INSTRUCTIONS ...
Страница 10: ...10 ...
Страница 11: ...11 ...