background image

Low add lubricant step: (as pictured)
1. Stop running belt, the folding machine;
(2) take the frame on the back of the run wave;Took oil can reach as far as possible into the run middle
3. Run an elastic adjustment
All the running machine in the factory before and after installation to adjust running belt, but after using a
period may also appear relaxation phenomenon.Such as: the user to pause the phenomenon of sliding at
running.When appear this phenomenon, in a half circle clockwise, synchronous adjustment to run around with
adjusting bolts.Run with too loose, foot in running, running belt and roller turn produce skid phenomenon, but
too close is not good, easy to increase the load of the motor, damage to the motor, running belt and roller, etc.
4. Run belt running deviation adjustment

The treadmill has been adjusted and passed QC inspection before leaving the factory. If there is
phenomenon of bias running of the belt, the possible reasons might be:

A. The frame is not stably laid
B. The user is not running on the centre of the running belt;
C. The user’s two feet are not using even strength.

For bias which can not be fixed automatically, try the following methods to fix the belt, as picture shown

-9-

A

B

C

If the belt tends to move to the right, you should turn the
belt adjustment screw on the right in clockwise
direction. We recommend you turn 1/4 turn each time
and check how it works. If the belt remains slanting to
the right ,then turn the belt adjustment screw on the left
in counterclockwise direction 1/4,as shown in the
picture A
If the belt tends to move to the left, then turn the belt
adjustment screw on the left in clockwise direction for
1/4 turn. If the belt remains slanting to the left ,then turn
the belt adjustment screw on the right in
counterclockwise direction for 1/4 turn, as shown in the
picture B

After having been used for a period, the belt might be
slightly elongated, and slipping and halting might appear
when a person is running on it. When these phenomena
appear, you should secure the screws on both sides for
1/4 turn. If the belt is too tight just loosen the screw on
both sides for 1/4 turn, as shown in pict

ure

c.

Содержание SP6612

Страница 1: ...Luxury electric running machine instruction User s Manual ...

Страница 2: ...considerations 1 二 Product introduction 2 三 Installation guide 5 四 Foiding Expansion Movment 8 五 Product maintenance 8 六 Fitness guide 10 七 Electricity run common faults and processing methods 11 八 Service commitment 12 ...

Страница 3: ... treadmill is folded grab handle lean back running machine can use at the base of the wheels for movement Low down the machine use walking living body tail and then the corresponding position below with the feet light play no support after the machine automatically Fold down the machine light played this position with their feet ...

Страница 4: ...ody The ground to level off confirm the treadmill placed after smooth reliable foot touchdown just can use Power plug must be reliable grounding the same power supply line to avoid the use of other electrical appliances Use running unit should wear sportswear and appropriate shoes barefoot on the treadmill exercise is forbidden It is forbidden to two or more than two people at the same time in thi...

Страница 5: ...assage dumbbell sit ups four kinds of functions 6 special safety pulled off switch with emergency stop function 7 has over current and short circuit protection function 8 with functions of speed direct elections 9 wear resisting elastic running board 10 running machine folding design make the installation more convenient save worry 11 MP3 function When electricity connect MP3 or other audio equipm...

Страница 6: ...ize 1740 680 1220 mm Effective running area 1260 450 mm power 2 0HP speed 1 14 km h function Running sprain back sit ups massage weight N W 56 kg G W 62 kg 3 Electronic watch display handrail riser U tube Motor cover Hook foam Protection strip Running belt Moving wheel base Protective shell massager ...

Страница 7: ...bell cover Accessories Serial number name number remarks 1 Screw M8 70 4 2 Screw M8 50 2 3 Screw M8 45 2 4 Screw M8 15 6 5 Screw M5 10 4 6 M8 nut 2 pcs gasket10pcs key 7 Multifunctional screwdriver 5mm 6mm Allen wrench in each one 8 13 to 15 open end wrench a oil 4 ...

Страница 8: ...connected to the U pipe thread hole and tighten Gasket with M8 x50 screw 2 4 nut 2 through the function frame and u shaped tube hole to tighten connection 4 massage Massage machine under the first three screw screw down then head on function frame plate of well hole tighten plucked screws to mount on a massage belt All the install screws to clean again confirm the screws are tight 5 About set cove...

Страница 9: ...d speed reduction B speed quick keys 3 6 9 12 km H 二 key 1 prog 1 programming key in stop state press program can choose circle program manual mode to P1 P2 P3 P4 P5 P6 and P7 P8 to manual mode 12 automatic programming standby mode press program can choose automatic program time can be set 5 99 points choose the right press start button to enter the program speed switch and direct key is invalid s...

Страница 10: ...changan and continuously 6 the speed manual operation mode by pressing this button can be slow every time minus 0 1 changan continuous reduction 7 speed shortcut 3 6 9 12 km H In the motor running state press the button will be marked on the motor speed adjustment to directly to the key value of speed 8 the safety lock function In any state pull off the safety lock can be emergency stop the operat...

Страница 11: ...ents the former must be sucked in the safety switch side panel of the safety lock position the other end of the clip on the practitioner s clothing 五 product maintenance 1 lubrication Running belt use after period of time must use special configuration of the methyl silicone oil for lubrication Suggestion use time less than 3 hours a week for 5 months 1 lubrication Use 4 to 7 hours a week 1 2 mont...

Страница 12: ...ably laid B The user is not running on the centre of the running belt C The user s two feet are not using even strength For bias which can not be fixed automatically try the following methods to fix the belt as picture shown 9 A B C If the belt tends to move to the right you should turn the belt adjustment screw on the right in clockwise direction We recommend you turn 1 4 turn each time and check...

Страница 13: ...ation skid phenomenon mainly adjusted by the user themselves Adjust steps right motor first fixed nut loose 4 to counterclockwise Using a wrench to adjust the bolt clockwise Adjusting range will be subject to run on load no skid Set before you will be in front of the loose screw 六 fitness guide Adjust screw Warm up Before exercise take a few minutes to do some stretching exercises it is strictly p...

Страница 14: ...e 2 changed new one E4 Over voltage protection 1 The voltage is too high 2 Motor fault 3 The motor is normal E5 When the motor running current is too large more than the rated current 1 Check whether the motor is damaged 2 If the motor is blocked 3 Due to the power grid pulse voltage occasional protected shutdown to boot 4 Replace the controller E7 Said electronic safety lock signal was detected 1...

Страница 15: ... of the warranty period under normal use products affect the normal function of fault 3 one of the following does not belong to the warranty scope Low artificial damage Damage to force majeure factors natural disasters such as earthquakes Improper use not according to operation manual specification or improperly secured such as electricity run circuit into the water More than product warranty 12 ...