Charging cycles:

The charging cycles of the new battery chargers have been specially developed so as to optimise the charging of all conven-
tionally available batteries. The range of different technologies employed in the batteries commercially available today require 
different charging characteristics to ensure correct and complete charging. The JMP Skan chargers extend the life of your 
batteries as they guarantee the right charging cycle for each type of battery.

1. First diagnostics step: “Diagnostic I” (initial diagnosis)

The charger analyses the battery’s charge level and the 
voltage with which it needs to be charged.

2. First charging step: “Repair Mode” (desulphurisation)

Charging with pulse current until the battery achieves the 
optimum voltage and current values to commence the 
second charging step.

3. Second charging step: “Initial Charge” (battery activation) Charging with reduced, constant current.
4. Third charging step: “Bulk Charge”
    (charge with constant current)

Charging with constant current until maximum battery 
voltage is achieved.

5. Fourth charging step: “Absorption Charge”
    (charge with constant voltage)

Charging with stabilised current until current reaches 
minimum values.

6. Fifth charging step: “Optimise”
    (for Recon charging mode only)

Intensive charging phase with constant current and increa-
sing voltage to boost the battery’s charging performance.

7. Second diagnostic step: “Diagnostic II”
    (second diagnosis)

The charger checks the status of the charged battery.

8. Sixth charging step: “Float Mode”
    (trickle charge with constant voltage)

Trickle charging with constant, reduced voltage.

9. Seventh charging step: “Trickle Mode”
    (trickle charge with pulse current)

Trickle charging with pulse current (constantly available).

Safety precautions:

JMP Skan battery chargers are equipped with protective features to ensure maximum safety during operation and use of the 
device.
•  Complete protection against generation of sparks
•  Protection against short circuits
•  Voltage compensation
•  Protection against overheating
•  Protection against reverse polarity
•  IP 20

JM-Products

Hammerbrookstr. 97 
20097 Hamburg
Deutschland
Tel.: + 49 (0) 40 2 37 21-0
www.jmproducts.eu

Содержание Skan 25.0

Страница 1: ...d is corrosive In case of accidental contact between the acid and the skin or eyes rinse immediately under running water and consult a doctor When connecting and disconnecting the battery wear safety glasses and keep the battery away from your face at all times Keep out of reach of children This device is not a toy and must not be used as such This device should not be operated by people including...

Страница 2: ... of 12 V batteries 5 Ah to 100 Ah Trickle charging of 12 V batteries 5 Ah to 150 Ah Suitable for the charging of lithium batteries LiFePO4 no other types of lithium batteries 12 5 A Charging of 12 V batteries 70 Ah to 250 Ah Trickle charging of 12 V batteries 70 Ah to 360 Ah Suitable for the charging of lithium batteries LiFePO4 no other types of lithium batteries 25 A Charging of 12 V batteries 1...

Страница 3: ...e car showroom without draining the battery Only in 12 V mode SUPPLY Power supply function 14 0 V To activate this function press and hold the Mode button for 5 seconds This function is used to maintain the power supply to a vehicle s memory modules when changing the battery or in all cases where the battery is disconnected from the vehicle s electrical circuit Only in 12 V mode CAUTION IN THIS FU...

Страница 4: ... Charging with constant current until maximum battery voltage is achieved 5 Fourth charging step Absorption Charge charge with constant voltage Charging with stabilised current until current reaches minimum values 6 Fifth charging step Optimise for Recon charging mode only Intensive charging phase with constant current and increa sing voltage to boost the battery s charging performance 7 Second di...

Отзывы: