background image

 

Pin 1: +ve polarity signal 

Pin2; -ve polarity signal   

Pin3: Grounded. 

      3

DMX512 cable must use the professional shielded twisted pair cable; standard 

loudspeaker cable is not reliable to control the long-range data.24AWG cable is suitable for 

more than 300 meters long-distance signal transmission and must add DMX 512 signal 

amplifier. 

      4

Do not use two outputs to separate the connection, if separate a continuous connection 

to branch, DMX512 splitter is necessary.If use the DMX512 splitter. At first connect 

DMX512 Splitter input terminal to controller .And then connected from the splitter output 

terminal to next device.Do as above guide to connect other device, and finally coupled with 

terminal insertion. 

 

 

7.

 

AC POWER

 

7.1 

VOLTAGE, POWER, FUSE SPECIFICATION

 

 

Input Voltage

 

 

Frequency

 

 

Total Power

 

 

110~240V 

 

50/60Hz 

 

300W     

 

 

Fuse voltage

 

 

Electronic current

 

 

Specification

 

 

250V 

 

8A 

 

5

×

20 

7.2 

POWER PROTECT

 

The equipment must be operated by professionals; Make sure that the voltage of power supply 

must be comply with the voltage identified on the lamp, and must have an overload or leakage 

electrical protection. 

                   

ATTENTION 

   

 

  Factory has equipped the standard 3 pin plug socket. Connect the power supply as below table. 

If lamp cable is damaged, replacement should be operate by factory or qualified staff. Any 

question, please contact professionals or talk to a qualified electrician. 

 

Live wire (

L) 

Null (

N) 

Ground wire

 

 

BROWN

 

BLUE

 

Green

 

 

8

LED LAMP MODEL AND REPLACE

 

8.1   

LED LAMP DESCRIPTION

 

 

Содержание Fantastic Hybrid 180

Страница 1: ...1 LED Moving Head Light Net Weight 19 1KG Color Temperature 5800 K ...

Страница 2: ...ce 19 13 Simple troubleshooting 19 STATEMENT The product is good packing when ship out the factory All users should strictly abide by the warnings and instructions stated in this manual any damage and results due to misuse and the neglect of this operating manual will be excluded from the deal responsibility this manual will not informed in additionally if have technical changes 1 PRODUCT INTRODUC...

Страница 3: ...hite effect Rotation GOBO 9 GOBO white changeable Gobo size diameter 15 9mm image diameter 13mm Prism 8facet prism 3facet prism fixed frost function Beam angel 3 5 37 Dimmer 0 100 linear adjustment supports electronic strobe and adjustable strobe effect supports strobe macro function lens group optical system electric focusing linear zoom The photoelectric reset system is used After the error occu...

Страница 4: ...E 4 SAFETY INFORMATION 01 02 01 03 04 02 05 01 Display 02 Control wheel 01 DMX IN 02 DMX OUT 03 Power switch 04 Power in 05 Fuse 01 Lens 02 Body 03 Tilt Lock 04 Arm 05 Pan Lock 06 Handle 07 Light base 01 03 05 07 02 04 06 ...

Страница 5: ...IONS BEFORE USE ENERGIZED OR INSTALLING 1 Follow through the operation of security methods and pay attention to the warning signs on the specification and equipment 2 If you have any problem for how to safely operate the equipment Please contact your dealer 4 1 3 OPERATION IS PROHIBITED In automatic mode do not manually force equipment or equipment 4 1 4 POINTING IS PROHIBITED Never point the ligh...

Страница 6: ...ly Adequate additional protection should be taken for outdoor use All lamps lights and their fittings should be kept dry Overheating dust and excessive humidity must be avoided 4 6 BURST PREVENTION The product are certified at IP 20 levels only Adequate additional protection should be taken for outdoor use All lamps lights and their fittings should be kept dry Overheating dust and excessive humidi...

Страница 7: ...re less than 60 C 12 m 5 Fan or ventilation at least in the range of 0 5 meters can not be an obstacle 6 Do not place any object on the lens 7 Handling at least allow the device to cool for 20 minutes 8 Do not replace the non original parts Packed with fly case of 2in 1 OR 1 in 1 and carton box 5 PACKAGE 5 1 ATTACH FOLLOW ACCESSORY ACCESSORY CONTENT QUANTITY USER MANUL 1 Safety Steels Selection 1 ...

Страница 8: ...fy that the gear clamp is not damaged and can bear at least 10 times the weight of the equipment The verification building can bear the weight of at least 10 times the total weight of the equipment and fixture cable attached equipment 2 The fixture is mounted on the base of the lamp body inserts the fastener into the mounting hole of the base and holds the handle of the fastener to lock the 1 4 ri...

Страница 9: ...de to connect other device and finally coupled with terminal insertion 7 AC POWER 7 1 VOLTAGE POWER FUSE SPECIFICATION Input Voltage Frequency Total Power 110 240V 50 60Hz 300W Fuse voltage Electronic current Specification 250V 8A 5 20 7 2 POWER PROTECT The equipment must be operated by professionals Make sure that the voltage of power supply must be comply with the voltage identified on the lamp ...

Страница 10: ...manufacturer or its agent service provider or a qualified person 9 CONTROL PANEL Display to display all information of fixture Control wheel can turn right left and enter 10 CONTROL PANEL MENU OPERATE Main Menu Submenu 1 Submenu2 Function SET Function description DMX ADDRESS 1 512 To address 1 Address 1 Address 1 001 512 SAVE save and back ESC ESC FEATURES SETTING Run Mode DMX DMX Wire not active ...

Страница 11: ...t Pan Tilt Scan Speed setting fast Singl Clear Off keep signal data On clear signal data Full Colour Off half color function On full color function ShortCut Off Shortcust off for colors and GOBOS On Shortcust open for colors and GOBOS ADV ADVANCED FUNCTION RST Re setting and back SAVE Save and back ESC Save and back ADVANCED FUNCTION Redress ZEROSETTING Pan rotation 0 255 Adjust the begging state ...

Страница 12: ...5 need password Verify2 KEY need password ESC back MANUAL LAMP REST ALL MOTER All step motor do not adjust it XY MOTER Pan Tilt step motor adjust do not adjust it PART MOTER Other step motor except Pan Tilt YES The chosen step motor reset ESC Back TEST RUN AUTO Auto SOUND Sound ESC Back SMULATE DMX Pan 0 255 Control Channel on display Pan Fine Tilt Tilt Fine PT Speed Special Fun Colour Colour2 Col...

Страница 13: ...pe xxxx LED Lamp model Temp xxx Temperature Fan 1 0 9999 Fan rotation speed 1 Fan 2 0 9999 Fan rotation speed 2 DisVersion Vxxx Version of display software XY Version Vxxx Version of Pan Tilt software M1 Version Vxxx Software Version M1 M2 Version Vxxx Software Version M2 ESC Back ESC Back DISPLAY SETTING Light Set 1 7Lev Back Ground light level Light Off On Keep back ground light on 1Min Back lig...

Страница 14: ...amp Off 10M After 10 mins no signal come in Lamp off Lifh No signal come in lamp keep lighting 11 DMX Channels 24 CH Mode 16 CH Mode Function description DMX Value Function description 1 1 Pan 0 255 0 540 2 Pan Fine 0 255 Pan Fine 3 2 Tilt 0 255 0 270 4 Tilt Fine 0 255 Tilt Fine 5 3 Pan Tilt speed 0 255 Pan Tilt speed 6 4 Function setting 0 139 Empty 140 149 PAN TILT reset 150 159 Empty 160 169 Sm...

Страница 15: ...55 empty 9 6 Rotate GOBO speed 0 255 empty 10 7 Fixed GOBO 0 3 blank 4 9 GOBO 1 10 15 GOBO 2 16 21 GOBO 3 22 27 GOBO 4 28 33 GOBO 5 34 39 GOBO 6 40 45 GOBO 7 46 51 GOBO 8 52 57 GOBO 9 58 87 The effect GOBO from slow to fast shake 88 95 GOBO 1 Shake 96 103 GOBO 2 Shake 104 111 GOBO 3 Shake 112 119 GOBO 4 Shake 120 127 GOBO 5 Shake 128 135 GOBO 6 Shake 136 143 GOBO 7 Shake 144 151 GOBO 8 Shake 152 1...

Страница 16: ...4 17 19 GOBO 5 20 22 GOBO 6 23 25 GOBO 7 26 28 GOBO 8 29 31 GOBO9 GOBO Location GOBO rotation indexing mode 32 34 GOBO 1 35 37 GOBO 2 38 40 GOBO 3 41 43 GOBO 4 44 46 GOBO 5 47 49 GOBO 6 50 52 GOBO 7 53 55 GOBO 8 56 59 GOBO 9 GOBO shake from slow to fast GOBO rotation indexing mode 60 67 GOBO 1 Shake 68 75 GOBO 2 Shake 76 83 GOBO 3 Shake 84 91 GOBO 4 Shake 92 99 GOBO 5 Shake 100 107 GOBO 6 Shake 10...

Страница 17: ...st in anti clockwise 244 249 GOBO change when sound control 250 255 Random GOBO 12 9 GOBO Rota GOBO rotation indexing mode 0 255 Index GOBO rotation indexing mode 0 Stop 1 127 Run from fast to slow in clockwise 128 129 Stop 130 255 Run from fast to slow in clockwise 13 GOBO Rota fine 0 255 Empty 14 10 Prism 0 19 Empty 20 49 GOBO 1Index Function 50 75 GOBO 1 Rota Function 76 105 GOBO 2 Index Functi...

Страница 18: ...5 255 Linear frost 17 13 ZOOM 0 255 Linear zoom 18 Zoom Fine 0 255 Zoom Fine 19 14 Focus 0 255 Focus 20 Focus Fine 0 255 Focus Fine 21 Rota Focus 0 255 Empty 22 15 Strobe 0 31 Strobe Close 32 63 Strobe Open 64 95 Strobe from slow to fast 96 127 Strobe Open 128 143 fast open slow close step out Fast to slow 144 159 slow open fase close step in slow to fast 160 191 Strobe Open 192 223 Random Strobe ...

Страница 19: ...rmal and the normal output of switching power supply is 27V 2 If a one way function is not normal First find the driving plug of the circuit board of this road and change the two adjacent drive motor plugs to check out the problem of the board or the wiring or the motor 3 If a one way function is not normal First find the driving plug of the circuit board of this road and change the two adjacent d...