SECTION 3 - OPERATION - (ES, RT)
3124288
– JLG Lift –
3-3
3.5 MACHINE SETUP MENU (ES & RT)
The LOAD submenu within the machine setup menu is
used to configure the LSS. To access the Machine Setup,
Load menu, use the Left and Right arrow keys to select
MACHINE SETUP from the Top Level Menu. Press the
ENTER key to select the menu. Press the Left and Right
arrow keys to select LOAD from the MACHINE SETUP
menu. Press the Enter key to view the submenu.
The following table details the structure of the load sub-
menu and describes the meaning of the parameter.
3.6 CALIBRATION MENU (ES & RT)
The Load submenu within the Calibration Menu is used to
zero the Empty Platform weight.
To access the Calibration Load Menu, use the LEFT and
RIGHT Arrow keys to select CALIBRATION from the Top
Level Menu. Press the ENTER key to select the menu.
Press the LEFT and RIGHT arrow keys to select LOAD
from the CALIBRATION menu. Press the ENTER key to
view the submenu.
NOTE:
The Calibration Menu is not available in Access
Level 2.
Upon entry to the Calibration, Load Menu, the analyzer
will display:
CALIBRATE:
YES:ENTER, NO:ESC
Pressing the ESC key will return the user to the top level
menu and not disturb the prior calibration information.
Table 3-4. Machine Setup
Submenu
(Displayed on
analyzer1st LIne)
Parameter
(Displayed on
analyzer 2nd line)
Description
LOAD:
0 = NOT INSTALLED
Displays/adjusts the
LSS Module
1 = CUTOUT PLT
2 =CUTOUT ALL
Go to Discount-Equipment.com