Installation Procedures ______________
Installation should be performed by competent technicians
in accordance with local and state codes. In the absence of
these codes, the installation must conform to applicable
American National Standards: ANSI Z223.1-LATEST
EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-
LATEST EDITION (National Electrical Code) or in Canada,
the installation must conform to applicable Canadian
Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/
CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for
General Installation and Gas Plumbing) or Canadian
Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST
EDITION (for Electrical Connections).
Location Requirements ______________
Before installing the dryer, be sure the location conforms to
local codes and ordinances. In the absence of such codes
or ordinances the location must conform with the National
Fuel Gas Code ANSI.Z223.1 LATEST EDITION, or in
Canada, the installation must conform to applicable
Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas)
or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION
(for General Installation and Gas Plumbing).
The dryer must be installed on a sound level floor capable
of supporting its weight. Carpeting must be removed from
the floor area that the dryer is to rest on.
IMPORTANT: “The dryer must be installed on
noncombustible floors only.”
The dryer must not be installed or stored in an area where it
will be exposed to water and/or weather.
The dryer is for use in noncombustible locations.
Provisions for adequate air supply must be provided as noted
in this manual (refer to Fresh Air Supply Requirements
section).
Clearance provisions must be made from combustible
construction as noted in this manual (refer to Dryer Enclosure
Requirements section).
Provisions must be made for adequate clearances for
servicing and for operation as noted in this manual
(refer to Dryer Enclosure Requirements section).
The dryer must be installed with a proper exhaust duct
connection to the outside as noted in this manual (refer to
Exhaust Requirements section).
The dryer must be located in an area where correct exhaust
venting can be achieved as noted in this manual (refer to
Exhaust Requirements section).
IMPORTANT: The dryer should be located where a
minimum amount of exhaust ducting will be necessary.
The dryer must be installed with adequate clearance for air
openings into the combustion chamber.
CAUTION: This dryer produces combustible lint and
must be exhausted to the outdoors. Every 6 months,
inspect the exhaust ducting and remove any lint
buildup.
IMPORTANT: The dryer must be installed in a location/
environment, which the ambient temperature remains
between 40° F (4.44° C) and 130° F (54.44° C).
Unpacking / Setting Up ______________
Remove protective shipping material (i.e., plastic wrap and
optional shipping box) from the dryer.
IMPORTANT: The dryer must be transported and handled
in an upright position at all times.
The dryer can be moved to its final location while still
attached to the skid or with the skid removed. To remove
the skid from the dryer, locate and remove the four lag bolts
securing the base of the dryer to the wooden skid. Two are
at the rear base, and two are located in the bottom of the lint
chamber. To remove the two lag bolts located in the lint
chamber area, remove the front panel.
Leveling Dryer
To level the dryer, place 4-inch (10.16 cm) square metal
shims or other suitable material under the base pads. It is
suggested that the dryer be tilted slightly to the rear.
If more headroom is needed when moving the dryer into
position, the top console (module) may be removed.
To Remove Top Console (Module)
• Disconnect the ground wire (A in the illustration below)
located at the rear upper left corner of the dryer.
• Remove the six sets of nuts and washers (B in the
illustration below) holding the console (module) to the
base.
• Disconnect the white plug connector (C in the
illustration below) located on the top of the rear electric
service/relay box (provides power to the heat circuit).
• Disconnect air connection from the 3-way micro valve.
• Lift the console (module) off of the dryer base.
IMPORTANT: The dryer must be transported and handled
in an upright position at all times.