Safety Precautions ___________________

!

 WARNING

For your safety, the information in this manual must
be followed to minimize the risk of fire or explosion
or to prevent property damage, personal injury, or
loss of life.

The dryer must never be operated with any of the
back guards, outer tops, or service panels removed.
Personal injury or fire could result.

Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.

Do not spray aerosols in the vicinity of this appliance while
it is in operation.

Purchaser/user should consult the local gas supplier for
proper instructions to be followed in the event the user smells
gas.  The instructions should be posted in a prominent
location.

What To Do If You Smell Gas:

• Do not try to light any appliance.

• Do not touch any electrical switch.

• Do not use any phone in your building.

• Clear the room, building, or area of all occupants.

• Immediately call your gas supplier from a neighbor’s

phone.  Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

Installation and service must be performed by a qualified
installer, service agency, or gas supplier.

Dryer(s) must be exhausted to the outdoors.

Although JLA produces a very versatile dryer, there are some
articles that, due to fabric composition or cleaning method,
should not be dried in it.

!

 WARNING

Dry only water washed fabrics.  Do not dry articles
spotted or washed in dry cleaning solvents, a
combustible detergent, industrial chemicals, or “all
purpose” cleaner.  Explosion could result.

Do not dry rags or articles coated or contaminated
with gasoline, kerosene, oil, paint, or wax.
Explosion could result.

Do not dry mop heads.  Contamination by wax or
flammable solvents will create a fire hazard.

Do not use heat for drying articles that contain
plastic, foam, sponge rubber, or similarly textured
rubberlike materials.  Drying in a heated tumbler may
damage plastics or rubber and may be a fire hazard.

The possible presence of residual quantities of aggressive
or decomposed chemicals in the load may produce damage
to the machine and harmful fumes.

A program should be established for the inspection and
cleaning of lint in the burner area, exhaust ductwork, and
area around the back of the dryer.  The frequency of
inspection and cleaning can best be determined from
experience at each location.

!

 WARNING

The collection of lint in the burner area and exhaust
ductwork can create a potential fire hazard.

For personal safety, the dryer must be electrically grounded
in accordance with local codes and/or the National Electrical
Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada,
the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990
or LATEST EDITION.

NOTE: Failure to do so will void the warranty.

Under no circumstances should the dryer door switch, the
lint drawer switch, or the heat safety circuit ever be disabled.

!

 WARNING

Personal injury or fire could result.

This dryer is not to be used in the presence of dry cleaning
solvents or fumes.

Remove articles from the dryer as soon as the drying cycle
has been completed.

!

 WARNING

Articles left in the dryer after the drying and cooling
cycles have been completed can create a fire hazard.

Read and follow all caution and direction labels attached to
the dryer.

For safety, proper operation, and optimum performance, the
dryer must not be operated with a load less than sixty-six
percent, 79 lb (35.83 kg) of its rated capacity.

!

 WARNING

You must disconnect and lockout the electric supply
and the gas supply or the steam supply before any
covers or guards are removed from the machine to
allow access for cleaning, adjusting, installation, or
testing of any equipment per OSHA standards.

IMPORTANT: The dryer must be installed in a location/
environment, which the ambient temperature remains
between 40° F (4.44° C) and 130° F (54.44° C).

!

 WARNING

Disconnect power before resetting the hi-limit.  The
hi-limit is located on the left side of the burner box,
looking at the burner from the back of the dryer.
Press and release and the hi-limit will reset.

Содержание D120

Страница 1: ...e gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion and to...

Страница 2: ...__________________________________________________ ___________________________________________________________________________________________________ Replacement parts can be obtained from your distributor or JLA When ordering replacement parts from JLA you can FAX your order to JLA at 01422 824390 or telephone your order directly to the JLA Parts Department at 01422 822282 Please specify the dry...

Страница 3: ...i limit switch trips a service call is required to investigate the reason and resolve the issue FOR YOUR SAFETY Do not dry mop heads in the dryer Do not use dryer in the presence of dry cleaning fumes The dryers must not be installed or stored in an area where it will be exposed to water and or weather The wiring diagram for the dryer is located in the front electrical control box area Table of Co...

Страница 4: ...tumbler may damage plastics or rubber and may be a fire hazard The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produce damage to the machine and harmful fumes A program should be established for the inspection and cleaning of lint in the burner area exhaust ductwork and area around the back of the dryer The frequency of inspection and cleaning can...

Страница 5: ..._______________ _______________________________________________________________________________________________________________________________ _______________________________________________________________________________________________________________________________ _______________________________________________________________________________________________________________________________ ...

Страница 6: ...OXIMATE SHIPPING WEIGHT 1 430 lb 648 64 kg AIRFLOW 60 Hz 2 800 cfm 79 29 cmm 50 Hz 2 333 cfm 66 06 cmm EXHAUST CONNECTION DIAMETER 16 40 64 cm COMPRESSED AIR CONNECTION 1 4 Quick Connection COMPRESSED AIR VOLUME 2 50 cfh 0 07 cmh OVEN SIZE kW Btu hr kcal hr 72 245 729 61 923 VOLTAGE AVAILABLE 208 480v 3ø 3 4w 50 60 Hz APPROXIMATE NET WEIGHT 1 450 lb 657 71 kg APPROXIMATE SHIPPING WEIGHT 1 500 lb 6...

Страница 7: ...hone 01422 822282 7 Mechanical Specifications _______________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation ...

Страница 8: ...outside as noted in this manual refer to Exhaust Requirements section The dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual refer to Exhaust Requirements section IMPORTANT The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be installed with adequate clearance for air openings into the combustio...

Страница 9: ...ms are located above the dryers a minimum of 18 inches 45 72 cm above the dryer console module is required Dryers may be positioned sidewall to sidewall however 1 or 2 inches 2 54 or 5 08 cm is suggested for ease of installation and maintenance Allowances must be made for the opening and closing of the control door and the lint door Fresh Air Supply Requirements ______ This appliance may only be i...

Страница 10: ...haust Requirements _______________ General Exhaust Ductwork Information Exhaust ductwork should be designed and installed by a qualified professional Improperly sized ductwork will create excessive back pressure which results in slow drying increased use of energy overheating of the dryer and shut down of the burner by the airflow sail switches burner hi limits or tumbler hi heat thermostats The d...

Страница 11: ...t be greater than 3 1 2 to 1 These figures must be increased in proportion if the main duct run to the last dryer to where it exhausts to the outdoors is unusually long over 20 feet 6 09 meters or has numerous elbows more than two in it In calculating ductwork size the cross sectional area of a square or rectangular duct must be increased twenty percent for each additional 20 feet 6 09 meters The ...

Страница 12: ...ctwork can only be increased to an extent Maximum proportional ductwork runs cannot exceed 20 feet 6 09 meters more than the original limitations of 20 feet 6 09 meters with two elbows When the ductwork approaches the maximum limits as noted in this manual a professional HVAC firm should be consulted for proper venting information Exhaust back pressure measured by a manometer magnehelic in the exh...

Страница 13: ...ION The ground connection may be to a proven earth ground at the location service panel NOTE A grounding connection terminal lug is provided in the dryer s electrical service relay box at the rear upper left hand corner of the dryer For added personal safety when possible it is suggested that a separate ground wire sized per local codes be connected from the ground connection of the dryer to a gro...

Страница 14: ...s supply shutoff and an external gas supply shutoff must be provided Technical Data Gas Specifications Gas Connections Inlet connection 1 F B S P T Inlet supply size 1 1 4 N P T minimum Btu hr input 375 000 94 498 kcal hr Natural Gas Regulation is controlled by the dryer s gas valve s internal regulator Incoming supply pressure must be consistent between a minimum of 6 0 inches 14 92 mb and a maxi...

Страница 15: ...89 47 kPa Installation Instructions To ensure an adequate supply of steam is provided be sure that the steam supply lines and steam return lines are sized and laid out as stipulated in this manual Inadequate steam supply lines and steam return lines or improper steam plumbing will result in poor performance and can cause component failure Clean dry steam must be provided to the dryer IMPORTANT Ste...

Страница 16: ...ed with coil positioned directly above the valve body The supply line and the return line should be insulated This will save energy and provide for the safety of the operator and maintenance personnel Water pockets in the supply lines caused by low points will provide wet steam to the coil possibly causing steam coil damage All horizontal runs of steam supply piping should be pitched 1 4 inch 6 35...

Страница 17: ...tric box covers have been replaced Check all service doors to assure that they are closed and secured in place Be sure the lint drawer is securely in place NOTE Lint drawer must be closed to activate the safety switch otherwise the dryer will not start Rotate the tumbler drum by hand to be sure it moves freely Check bolts nuts screws terminals and fittings for security STEAM MODELS check to ensure...

Страница 18: ...witch on gas models NOTE To check for proper sail switch operation open the main door and while holding main door switch plunger in start the dryer The dryer should start but the heat circuit should not be activated on If the heat burner does activate shut the dryer off and make the necessary adjustments Reversing tumbler dryers should never be operated with less than a 79 lb 35 83 kg load dry wei...

Страница 19: ...bustible The accumulation of lint can create a potential fire hazard Keep dryer area clear and free from combustible materials gasoline and other flammable vapors and liquids NOTE Remove power from the dryer before performing any maintenance in the dryer Suggested time intervals shown are for average usage which is considered six to eight operational running hours per day IMPORTANT The dryer produ...

Страница 20: ... or continue through the drying cycle with no heat Manual reset hi limit must be reset manually This hi temperature condition may be caused due to a restricted exhaust poor airflow or improper burner operation The location of the burner hi limit is on the left side of the burner box looking at the burner from the back of the dryer WARNING Discontinue power to dryer before attempting to reset hi li...

Страница 21: ...ignitor will shut off and the gas valve will be energized Ignition flame should now be established With the burner flame on remove the flame sensor wire from the S2 terminal of the HSI module The burner flame must shut off immediately CE Label 4 Heat Input For Gas Dryers This describes the heat input in British thermal units per hour Btu hr or kilowatts kW 5 Orifice Size For Gas Dryers Gives the n...

Страница 22: ...hen the L E D is ON AUX _ This L E D will indicate the status of the S A F E system output If the request to turn on the S A F E system is made then the L E D is ON Input Output Board Input Description Red L E D FUSE _ This L E D will indicate the status of the F2 which fuses the 24 VAC supplied to the board LINT _ This L E D will indicate the status of the Lint Drawer If the drawer is closed then...

Страница 23: ...haust temperature rise 25 F greater than set point this will be the trip point and the S A F E system routine will activate Once the S A F E system routine is activated water will be injected into the tumbler chamber Anytime water is being injected into the tumbler the tumbler drive will turn the load for 1 second every 15 seconds This process will continue for a minimum of 2 minutes After 2 minut...

Страница 24: ...Part No 113375 16 12 01 15 ...

Отзывы: