JL Audio m600 Скачать руководство пользователя страница 7

7

INPUT SECTION

The M600/6-24V’s input section allows you 

to send signals to the amplifier section through 
the use of two or four differential inputs.

Input connections are made via one or two 

pairs of traditional RCA-type jacks.

 

Ground

Remote

+24 VDC

NOT FOR USE IN 12V SYSTEMS!

 

If you wish to send six discrete channels into 

the M600/6-24V, simply use all six inputs and set 
the “Input Mode” switch in the “6 Ch.” position.

If you wish to feed all six channels by using 

only four channels of full-range input, set the 
Input Mode” switch to “4 Ch.” and use only 
the inputs to channels 1, 2, 3 & 4. In this mode, 
channels 5 & 6 will operate with a sum of the 1 & 
3 and 2 & 4 input signals, respectively.

If you wish to feed all six channels by using 

two channels of full-range input plus two 
channels of low-frequency input (subwoofer 
output from the source unit), first set the 

“Input Mode” switch to “6 Ch.”. Next, it will 
be necessary to split the full-range signals with 
y-adaptors and feed these signals into the inputs 
to channels 1 & 2 and 3 & 4. The dedicated 
subwoofer signal will be sent to channels 5 & 6. 

If you wish to use only two channels of input 

to deliver signal to all six amplifier channels, 
set the “Input Mode” switch to “2 Ch.” and use 
only the inputs to channels 1 & 2. In this mode, 
Channels 3 & 5 will operate with the channel 1 
signal and channels 4 & 6 will operate with the 
Channel 2 signal.

 

Input Voltage Range:

 

The M600/6-24V’s input sections are designed 

to accept signal voltages from 100mV – 4V.  This 
will accommodate all preamp level signals and 
many speaker level signals.

To use speaker-level sources, simply splice the 

speaker output wires of the source unit onto a 
pair of RCA plugs for each input pair. (or use JL 
Audio part XD-CLRAIC2-SW) No “line output 
converter” is needed in most cases. 

If you find that the output cannot be reduced 

sufficiently with a direct speaker level signal 
applied to the amplifier, you may use a “line 
output converter” to reduce the signal level.

INPUT SENSITIVITY CONTROLS

The controls labeled “Input Sens.” located in 

each channel section can be used to match the 
source unit’s output voltage to the input stage of 
each pair of amplifier channels for maximum 
clean output. Rotating the control clockwise will 
result in higher sensitivity (louder for a given 
input voltage). Rotating the control counter-
clockwise will result in lower sensitivity (quieter 
for a given input voltage.) 

 

 

To properly set the amplifier for maximum 

clean output, please refer to Appendix A (page 
14) in this manual. After using this procedure, 
you can then adjust any or all “Input Sens.” 
levels downward if this is required to achieve the 
desired system balance. 

Do not increase any “Input Sens.” setting for 

any channel(s) of any amplifier in the system 

beyond the maximum level established during 

the procedure outlined in Appendix A (page 14). 

Doing so will result in audible distortion and 

possible speaker damage.

Содержание m600

Страница 1: ...nt to ensure optimum performance from this product Should you decide to install the amplifier yourself please take the time to read this manual thoroughly so as to familiarize yourself with its instal...

Страница 2: ...ber Please take the time to enter that number in the space provided below The serial number can be found on the bottom panel of the amplifier and on the amplifier packaging Serial Number INSTALLATION...

Страница 3: ...plifier using appropriate hardware so that it does not come loose in the event of a collision or a sudden jolt to the vehicle or vessel Stupid Mistakes to Avoid Check before drilling any holes in your...

Страница 4: ...power wire to the negative battery post Use the same size power wire as the wire connected to the 24V connection minimum 8 AWG 5 Run signal cables and remote turn on wire from the source unit to the...

Страница 5: ...m of insulation from the end of each wire and insert the bare wire into the terminal block seating it firmly so that no bare wire is exposed While holding the wire in place tighten the set screw firml...

Страница 6: ...that derives power from an ignition switched circuit Ground Remote 24 VDC NOT FOR USE IN 12V SYSTEMS The M600 6 24V s Remote turn on connector is designed to accept 18 AWG 12 AWG wire To connect the r...

Страница 7: ...with the Channel 2 signal Input Voltage Range The M600 6 24V s input sections are designed to accept signal voltages from 100mV 4V This will accommodate all preamp level signals and many speaker leve...

Страница 8: ...hannels 1 2 another filter for channels 3 4 and a third filter for channels 5 6 Each of these filters can be configured independently into one of two filter types or defeated completely by way of the...

Страница 9: ...from a single HD RLC controller using a simple phone line splitter and multiple phone cables When connected to the amplifier the HD RLC operates as follows At full counter clockwise rotation the audio...

Страница 10: ...n bridged each channel will deliver optimum power into a 4 ohm load When a pair of channels are bridged they will deliver 200W x 1 into a 4 ohm load or 150W x 1 into an 8 ohm load Operating a pair of...

Страница 11: ...n This functionality can be used to diagnose a short circuit by only connecting one channel at a time The Status LED will turn amber when you connect the channel that is experiencing the problem and t...

Страница 12: ...de switch Result the relative level of the LF and HF channels will be fixed by the M600 6 24V s Input Sens settings and will not be user adjustable from the helm unless an optional HD RLC is connected...

Страница 13: ...source unit s dedicated subwoofer output is connected to the CH 5 Left and CH 6 Right inputs select 6 Ch on the Input Mode switch Result in this mode the user has the ability to control the absolute...

Страница 14: ...speaker system connected to the amplifier outputs 6 Verify that you have disconnected the speakers before proceeding Play a track with an appropriate sine wave within the frequency range to be amplifi...

Страница 15: ...referred to rated power A weighted 20 Hz 20 kHz noise bandwidth 84 dB referred to 1W A weighted 20 Hz 20 kHz noise bandwidth Frequency Response 12 Hz 22 kHz 0 1dB Damping Factor 150 4 ohms per ch 50...

Страница 16: ...uired To test for this problem jump the 24VDC wire to the Remote terminal to see if the amplifier turns on I hear a repetitive ticking or popping sound coming out of the speaker s Check the speaker wi...

Страница 17: ...source unit while an appropriate test tone is played through the source unit disconnect the input cables from the amplifier prior to this test The frequency used should be in the range that is to be...

Страница 18: ...18 JL Audio M600 6 24V Owner s Manual INSTALLATION NOTES Use this diagram to document your amplifier s switch and control positions...

Страница 19: ...19...

Страница 20: ...ereafter Some states do not allow limitations on implied warranties therefore these exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights whi...

Отзывы: