USR-TCP232-410S User Manual
5 / 46
PC Local Connection Configuration
1.3. Default Parameter Test
Default parameter is as below excel:
User name
admin
Password
admin
IP address
192.168.0.7
Subnet Mask
255.255.255.0
Default Gateway
192.168.0.1
Default Work Mode
TCP Server
Default Local Port
23
Baud Rate
115200
Parity bit/Data bit/Stop bit
None/8/1
Data Transmission Test:
1) Open test software “USR-TCP232-Test.exe”, and do hardware connection according to Chapter 1.1
Hardware Testing Environment.
2) The right side is Network Settings: TCP Client, IP address: 192.168.0.7, port #: 23, click “Connect”
to build TCP connection.
The left side is Serial Settings: Baud Rate: 115200, Parity/Data bit/Stop bit: None/8/1,
Click “Open” to enable the COM.
Then we can test data transmission between COM and network.
Data from serial to network is: PC’ COM->410S’ COM->410S Ethernet port->PC Network;
Data from network to serial is: PC Network->410S Ethernet port->410S’ COM-> PC’s COM.
Содержание USR-TCP232-410S
Страница 1: ...USR TCP232 410S User Manual 1 46 USR TCP232 410S Manual File Version V1 0 0...
Страница 3: ...USR TCP232 410S User Manual 3 46 5 3 Serial Configuration 45 6 Contact 46...
Страница 6: ...USR TCP232 410S User Manual 6 46 The below picture is for your reference Default Parameter Test...
Страница 15: ...USR TCP232 410S User Manual 15 46 UDP Client Software Configuration UDP Client Testing Screenshot...
Страница 20: ...USR TCP232 410S User Manual 20 46 USR VCOM Add a COM USR VCOM Build Connection...
Страница 22: ...USR TCP232 410S User Manual 22 46 Web to Serial Webpage...
Страница 23: ...USR TCP232 410S User Manual 23 46 Web to Serial COM Send Receive Data...
Страница 37: ...USR TCP232 410S User Manual 37 46 Software Configuration Full Show...
Страница 40: ...USR TCP232 410S User Manual 40 46...