RFC2217 protocol to improve accuracy of transmission.
Protocol length is 8 bytes. And values taken for example is in HEX:
Name
Packet
Header
Baud Rate
Bytes parameter
Parity
Bytes
3
3
1
1
Explanation
reduce
misjudgment
High is in front,
smallest is
600(00 02 58)
data bytes, baud
rate, parity
Remove 4 bits
of header and
ignore the high
bit
(115200,
N,8,1)
55 AA 55
01 C2 00
03
46
(9600,
N,8,1)
55 AA 55
00 25 80
03
28
Serial parameter bit:
Bit #
Explanation
Value
Description
1:0
Data bit selection
00
5 bits
01
6 bits
10
7 bits
11
8bits
2
Stop Bit
00
1 bit
01
2bits
3
Parity Enable
00
Disable Parity
01
Enable Parity
5:4
Parity Type
00
ODD
01
EVEN
10
Mark
11
Clear
8:6
NC
000
0
Using methods:
1. USR-TCP232-M4,E45 Setup software, click “Synchronous baud rate (RFC2217)”.
2. When serial parameter changes is needed, it send RFC 2217 packet. 410S receive the command
from network and revise serial parameter accordingly.
Содержание USR-TCP232-410S
Страница 1: ...USR TCP232 410S User Manual 1 46 USR TCP232 410S Manual File Version V1 0 0...
Страница 3: ...USR TCP232 410S User Manual 3 46 5 3 Serial Configuration 45 6 Contact 46...
Страница 6: ...USR TCP232 410S User Manual 6 46 The below picture is for your reference Default Parameter Test...
Страница 15: ...USR TCP232 410S User Manual 15 46 UDP Client Software Configuration UDP Client Testing Screenshot...
Страница 20: ...USR TCP232 410S User Manual 20 46 USR VCOM Add a COM USR VCOM Build Connection...
Страница 22: ...USR TCP232 410S User Manual 22 46 Web to Serial Webpage...
Страница 23: ...USR TCP232 410S User Manual 23 46 Web to Serial COM Send Receive Data...
Страница 37: ...USR TCP232 410S User Manual 37 46 Software Configuration Full Show...
Страница 40: ...USR TCP232 410S User Manual 40 46...