3. pattern projection blur
Check whether the value of the electronic focus
channel is suitable for the projection distance
now.
4. the lamps and lanterns work intermittently
The reason is: the internal line is protected.
Check whether the fan operates normally or
whether it is dirty or not, causing the interior
temperature of the luminaire to rise.
Check whether the internal temperature control
switch is closed.
Check whether the bulb is in service life and
replace the new bulb.
5. control table is not controlled after normal
reset
Possible reasons: signal line failure or lamp
parameter settings are abnormal.
Check the initial address code and check the
connection of the DMX signal line (whether the
signal wire and cable are intact, and whether
the connection is loose).
Add signal amplifier, plus 120 ohmic terminal