![Jifon AquaHeat 13 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/jifon/aquaheat-13/aquaheat-13_user-manual_4005293031.webp)
31
AH-01
1
2 3 4
5
6
590mm
500mm
730mm
Installation Manual
Measurements and Connections
(13kW-18kW)
Ø connection for outgoing water
1.
Ø connection for incoming water
2.
Ø connection for outgoing refrigerant
3.
Ø connection for incoming refrigerant
4.
Ø electrical connection
5.
Ø electrical connection
6.
Technical Data
Model AquaHeat
Model AquaHeat
TM
TM
Unit
13kW
18kW
25kW
Electrical connection
400 V, N3 phases
Fuse
A
16D
25D
Compressor, type
Scroll
Compressor, maximum input
kW
4,26
5,66
8,47
Compressor, displacement
m
3
/h
14,1
19,3
28,3
Maximum water temperatures
°
C
55
Refrigerant R407c
kg
~1,8
~2
~4
Cut-off pressure min/max R407c
bar
0,5/31
Minimum water fl ow
l/min
20
40
65
Dimensions GreenBox (HxWxD)
mm
730x590x500
Weight GreenBox
kg
95
102
120
JiControl control panel
size
16
16
25
Содержание AquaHeat 13
Страница 28: ...AH 01 28 Installation Manual Wiring Diagrams Three phase 400 V...
Страница 29: ...29 AH 01 Installation Manual...
Страница 30: ...AH 01 30 Installation Manual...