9
Combustion
Combustion air
Combustion air is settled by a manual control, which regulate the working speed of your
fireplace, after started.
Convection air
Originally, your appliance operates with ventilation controlled by a speed controller and an
airstat. Depending on the chosen position, the speed controller determines the forced hot
air flow outside your fireplace (maximum power heating is reached with ventilation on the
highest level).
The airstat (on the left side of the device) is an accessory which turns on and off ventilation
according to temperature sensor. This ventilation turns on once the fireplace has reached a
certain temperature. Ventilation must always turn when the fireplace is hot, otherwise the
fans will be degraded. Hot air outlet will allow a hot convection air distribution in the room
of the fireplace or in another room. If you have this type of installation, it is essential to take
advice from your approved installer.
There is an option "stop air" which fosters the hot convection air distribution through other
holes, by filling the convection air outlet on the top of the fireplace.
Appliances without ventilation MUST have 2 hot air outlets with a finishing grid (not
included). These 2 hot air outlets must be plugged to at least 1 meter flexible diameter 125
mm.