Jide PURE L Скачать руководство пользователя страница 7

Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – 

www.jide.be

 - 

[email protected]

 

 

PURE (EN) June 2018 

Additional parts 

– Identification plate 

 

In addition to the fireplace, the packaging contains the following elements: 
 

A poker; 

A cold handle; 

A glove; 

A speed controller to regulate ventilation (for fireplaces with ventilation); 

A short stainless steel duct 45° right-angled for the smoke link; 

A plate and a fixing screw (to fill the air inlet on the back in case of connection from 
the bottom); 

A  paint  spray  for  eventual  retouching.  Attention:  before  using  the  fireplace,  make 
sure to get the spray out and to keep it away with a minimum distance of 2 m. 

On the packaging, instructions for use with identification plate. 

All  the  Jidé  fireplaces  are  registered  as  soon  as  they  leave  production,  according  to  the 
information  contained  on  a  plaque  that  accompanies  this  notice,  stating  in  particular  the 
power, efficiency and CO emissions of the appliance. 
 
This  plaque  must  be  kept  and  will  enable  your  appliance  to  be  identified  in  our  files 
(traceability) if necessary. We advise you to paste it on this user and installation notice or on 
your invoice. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание PURE L

Страница 1: ...AND MAINTENANCE PURE L and PURE XL Congratulations You have chosen an appliance of the Jid range and we would like to thank you for it We are convinced that it will bring you warmth and comfort In or...

Страница 2: ...ION NOTICE 13 Preparation Arrangements 13 Fitting 15 Fitting of the finishing frame option 15 Fitting of the chimney connection 16 Fitting of the connection for the convection air option 16 Fitting of...

Страница 3: ...and old constructions as well as smoke flues The appliance may not be modified as it could present a real danger and will invalidate the warranty A list of our dealers installers is available on our...

Страница 4: ...air arrives under the grate and the stainless steel canals to foster fire lighting in the fireplace The preheated secondary air creates post combustion by reburning the gases and this greatly improves...

Страница 5: ...o possibility or necessity of an external combustion air inlet Remove the air box front side which allows to take combustion air in the room Leave also the back air inlet open 2 We connect the outside...

Страница 6: ...y and efficiency while limiting CO emissions Test results according to the standards EN 13229 2001 EN 13229 A1 2003 EN 13229 A2 2004 PURE L 67 Nominal power 9 12 kW Nominal efficiency 80 2 CO emission...

Страница 7: ...case of connection from the bottom A paint spray for eventual retouching Attention before using the fireplace make sure to get the spray out and to keep it away with a minimum distance of 2 m On the...

Страница 8: ...thermostat you have to reduce the air inlet according to the wished heat CAUTION For good performance do not remove completely the ashes of the stove When the fire needs a reloading set the speed con...

Страница 9: ...evice is an accessory which turns on and off ventilation according to temperature sensor This ventilation turns on once the fireplace has reached a certain temperature Ventilation must always turn whe...

Страница 10: ...lass and fouling of the flue An approved chimney sweep should be consulted for any questions regarding the good use and maintenance of the chimney General recommendations In the same way if overloaded...

Страница 11: ...onment The humid fumes have the disadvantages of reducing the draft and the formation of tar in the flue and on cold surfaces the window for example Split wood presents better combustion and will impr...

Страница 12: ...anty Deformation of the baffle Bleaching of the glass Degradation of the vermiculite Accentuated noise of the ventilator Deterioration of the automatic thermostat and of the airstat Excessive dilation...

Страница 13: ...perature of smoke to the chimney being able to reach 300 to 400 this one could cause a combustion of not isolated combustible materials Provide high temperature insulation around the fireplace to prot...

Страница 14: ...flue is much more important than the one of the stove it is advised to tube the chimney on all its height and to insure the sealing of connection It is necessary to be vigilant on the state of the ex...

Страница 15: ...replace must be aligned with respects to the plane of the masonry to enable the correct attachment of the frame A three and a four sided frame are available as options The finishing frame clips onto t...

Страница 16: ...ed for the chimney connection It fits onto the appliance When the duct is placed on the appliance fold back the 2 safety clamps Fitting of the connection for the convection air option Your appliance h...

Страница 17: ...ecific cases 1 No possibility or necessity of an external combustion air inlet Remove the air box front side which allows to take combustion air in the room and leave also the back air inlet open 2 Th...

Страница 18: ...nnection Your appliance is equipped with fans controlled by a speed controller This is the diagram for their electrical connection Attention disconnect the power before working on the electrical 1 Spe...

Страница 19: ...e bottom vermiculite 4 Remove the back vermiculite 5 Unscrew and remove the back plates Ventilation access Integrated ventilation and airstat access for Pure L 67 L 90 XL 77 XL 16 9 Unscrew and remove...

Страница 20: ...www jide be info jide be PURE EN June 2018 20 Manual setting air inlet access CAUTION We could not be held responsible for an improper installation These must be very neat and made according to standa...

Страница 21: ...this method on cold glass or on warm glass with a glove 2 With a damp cloth and wood ash The window can be easily cleaned with a cloth or slightly damp absorbent paper that has been previously soaked...

Страница 22: ...oise Before any work please disconnect the electricity supply The fan can be dusted if it is fouled Do not apply pressure to the fan blades at the risk of bending them and thus creating an imbalance t...

Страница 23: ...powerfull V M C or cooker extraction hood During the opening of the door Consult the installer Draft test with a depression meter Inspect the flue and sweep if necessary Review the air intake level o...

Страница 24: ...the position of the baffle Check the position and seal of the door joints The window fouls very quickly Damp wood Slightly insufficient draft Operating with the primary air not sealed Burn rate reduc...

Страница 25: ...ssued by the A R G B laboratories Royal association of Belgian gas fitters meeting the European EN 13229 A2 standard it was stated that The power in kW for Pure L 67 9 to 12 kW Pure L 90 11 to 13 kW P...

Страница 26: ...Jid s a Rue des Meuneries 11 B 4650 HERVE Belgique T l 32 87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be PURE EN June 2018 26 CE MARKING...

Страница 27: ...L 77 Pure XL 16 9 Energy efficiency class A Direct heat output Pure L 67 9 to 12 kW Pure L 90 11 to 13 kW Pure XL 77 11 to 13 kW Pure XL 16 9 12 to 14 kW Energy efficiency 80 2 The installation of thi...

Страница 28: ...terial will be exchanged after its return The following are excluded from the warranty Internal wear parts in contact with the flames and embers The vermiculite panels The joints of the door and ash b...

Страница 29: ...he immobilisation of the appliance resulting from warranty operations are to the charge the customer The warranty is only provided through the dealer agent on presentation of the purchase invoice Jid...

Страница 30: ...Jid s a Rue des Meuneries 11 B 4650 HERVE Belgique T l 32 87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be PURE EN June 2018 30 NOTES...

Страница 31: ...Jid s a Rue des Meuneries 11 B 4650 HERVE Belgique T l 32 87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be PURE EN June 2018...

Отзывы: