JHCOOL JH168 Скачать руководство пользователя страница 5

 

 

 

 

         

Page | 5

 

 

should not less than 85% of airflow when mechanical exhausting.) Mechanical 
can be combined with the natural exhaust. 

3. Debugging the cooler when the first running. Ensure that the operating current 
at the rated current range. 

4. Keep away any source of fire when assembling or operating the cooler. 

5. Ensure the supply voltage is within the rated +/-10V range, otherwise it will 
break the cooler such as cannot start the cooler or start and stop frequently. 

6. Keep the wall controller and the control lines away from strongly EMI (such as 
the equipment with frequency speed controller, SCR temperature and speed 
controller, high frequency heating circuit or super high power motor etc). It is 
better not to keep them at the same line of power lines, if you have to, then make 
sure the distance between them is more than 30cm. 

7. Please power OFF the cooler while it is raining or thundering. otherwise the air 
compressor will absorb moisture. 

8. The appliance must be fitted with means for disconnection from the supply 
mains having a contact separation in all poles that provide full disconnection 
under over voltage category III conditions, and these means must be 
incorporated in the fixed wiring in accordance with the wiring rules. 

9. Please make sure that the unit and power connection have good earthing, 
otherwise may cause electrical shock. 

10. This appliance is not intended for use by persons (including children) with 
reduced physical, sensory or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or instruction concerning 
use of the appliance by a person responsible for their safety. Children should be 
supervised to ensure that they do not play with the appliance. 

11. If the supply cord is damaged, it must be replaced by the manufacturer, its 
service agent or similarly qualified persons in order to avoid a hazard. 
 

5. 

INSPECTION AND PREPARATION BEFORE ASSEMBLING 

1. Please open the side panel to check the parts and the technical 
parameters(the manual), if the parts are incomplete or breakage, Leave it as it is 
.and inform us or the distributor. 

2. Check if the supply voltage is same as the rated one and the supply frequency 
same as rated one. Make the voltage is 230+/- 10V. 

3. Make sure the water is clean with a steady hydraulic pressure, 
0.2~0.6MPa(1.5~6kgf/cm2) 

Содержание JH168

Страница 1: ......

Страница 2: ...intain and troubleshoot your cooler Due to continuous research and development the specifications herein are subject to change without notice TABLE OF CONTENTS 1 FOREWORD 4 2 PRINCIPLE OF WORK 4 3 Caution 4 4 ATTENTION 4 5 INSPECTION AND PREPARATION BEFORE ASSEMBLING 5 6 GUIDE FOR INSTALLATION AND UNINSTALL OF TRUCKLES AND HORSE 6 7 GUIDE FOR INSTALLATION AND UNINSTALL OF SIDE PANEL 6 ...

Страница 3: ... 3 8 GUIDE FOR ADD WATER AND DRAIN 7 9 CIRCUIT DRAWINGS 7 10 INSPECTION AND DEBUGGING BEFORE RUNNING 7 11 GUIDE FOR OPERATION 8 12 CLEAN AND MAINTAINING 10 13 TROUBLE SHOOTING 11 14 TECHNICAL PARAMETERS 12 ...

Страница 4: ...clean air 3 Caution This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance If the supply...

Страница 5: ...l poles that provide full disconnection under over voltage category III conditions and these means must be incorporated in the fixed wiring in accordance with the wiring rules 9 Please make sure that the unit and power connection have good earthing otherwise may cause electrical shock 10 This appliance is not intended for use by persons including children with reduced physical sensory or mental ca...

Страница 6: ... 1 Take two sets of assembled frames as Pic 1 2 Use ST5 25 bolts to stable the assembled frame to the bottom of the water tank And lock the bolt closely with Phillips screwdriver Please pay attention to the hole at the tank while installation as Pic 2 7 GUIDE FOR INSTALLATION AND UNINSTALL OF SIDE PANEL 1 Loose 8 bolts with cross screwdriver as Pic 3 2 Pull up 2 pieces of dust screens and the side...

Страница 7: ... as pic 5 2 add water from this hole as pic 6 Drain Open the valve cover wither shins also close it clockwise after drain as pic 7 9 CIRCUIT DRAWINGS 10 INSPECTION AND DEBUGGING BEFORE RUNNING 1 Check the levelness when assembling cooler 2 Check if drain pipe has been assembled ...

Страница 8: ...foreign matter in the air compressor 9 Check if the power supply and the voltage are normal 10 Check if the running electrical current is in the rated range 11 Check if there is any shake when running the cooler 11 GUIDE FOR OPERATION Introduction of the LCD controller Introduction of the function of the button on the remote controller 1 ON OFF Start the cooler in stand by state or stop 2 SPEED Ch...

Страница 9: ...emperature will be showed on it 2 Airflow adjustable Press SPEED button on the LCD controller or SPEED on the remote controller to add or decrease it It can be changed from L M H L M H and that will be showed on the airflow indicator 3 Mode Press COOL button on the LCD controller the mode will be changed by COOL VENTILATION COOL When the cooler is start or operating switch to COOL mode it will be ...

Страница 10: ... c Press the ON OFF button after the timer takes effective 12 CLEAN AND MAINTAINING Please Power OFF the cooler before cleaning 1 Shell Cleaning please clean with mild cleaner and the soft cloth Evaporable liquor such as gas or alcohol is NOT allowed 2 Wet pad cleaning take out the pad and brush the dust on its surface with SOFT brusher 3 Water tank cleaning Set the time and frequency according to...

Страница 11: ...Add it The cool key on the controller is broken Replace the controller Electrical mainboard is broken Replace it 3 No airflow The key on the controller is broken Replace the controller The motor is broken Replace it 4 Unpleasant odour Dirty water Change it to clean water Dirty cooling pad Clean it Notice 1 The above is only for your reference if the problems can not be found in the table please co...

Страница 12: ...Pressure Pa 80 Speed 3 Power kW 0 38 Noise dBA 62 Voltage Frequency V Hz 220 240 50 Outlet Dimension mm 625 640 Rated Currency A 1 8 Pads Dimension mm 685 30 640 100 685 30 200 50 Net Weight kg 31 Overall Dimension mm 800 480 1380 Operating Weight kg 117 Water Store L 57 ...

Отзывы: