As this regulator is non-venting the internal pressure should be released before adjustment and be
allowed to build up again after adjustment.
10.
Check the flow through the regulator using the test flowmeter with the test connector plug
inserted in the injection orifice penetrator. With the supply set at 10 to 15 bar, the flowmeter
ball should lie between 1.0 and 2.0 lpm on the scale.
11.
If not, check the condition of the inlet filter on the single stage regulator and if it is corroded or
clogged, replace the inlet filter fitting (Fig 4.8, Item 22) and repeat Step 9. to verify the correct
flow. If the problem persists check the condition of the filter on the helmet sideblock elbow.
Replace if necessary and repeat step 9.
12.
If no further maintenance is to be performed, repack the SLS System ready for diving as
follows:
a.
Reload the actuation cable assembly (See Section 3.4.4, page 49).
b.
Recharge the gas cylinders with the appropriate heliox gas mix for the diving depth (See
Section 3.1.1, page 32).
c.
Install a refilled scrubber canister and check the door seal (See Section 3.1.2 and section
3.1.1, page 37).
d.
Replace and secure the outer door.
4.3.2
Monthly maintenance procedures
N
OTE
The following checks can be conducted using breathing quality compressed air, thereafter the SLS
System should be purged with Heliox and prepared for re-use. Do not under any circumstance
attempt to dive with air as a gas mixture in SLS. Diver will become hypoxic very quickly.
4.3.2.1 Perform weekly maintenance
1.
Carry out the weekly maintenance schedule in accordance with section 4.3.1 of this Manual.
4.3.2.2 Check scrubber door operation and sealing
1.
Inspect the scrubber door, which is shown in Fig 4.9), for damage or wear. Replace any
damaged or worn components as necessary.
2.
Lightly lubricate the main sealing O-ring (Fig 4.9, Item 7) on the scrubber door using an
oxygen compatible lubricant (e.g. Christo-lube fluorinated grease - Divex Part No SM034).
3.
Visually check the scrubber door operation and the sealing arrangement.
N
OTES
(1) Always ensure the CO
2
scrubber canister is correctly installed prior to diving.
(2) Ensure that the scrubber door is not over-tightened.
(3) Do not swap scrubber doors between different backpack housings’. Scrubber doors are
individually factory set and marked with the SLS System’s serial number.
Содержание Divex SLS Mk IV
Страница 2: ...Intentionally Blank...
Страница 4: ...ii OM131 Approval Sheet P1939 OM 131 R11 Intentionally Blank...
Страница 6: ...iv OM131 Preface P1939 OM 131 R11 Intentionally Blank...
Страница 8: ...vi OM131 List of Abbreviations P1939 OM 131 R11 Intentionally Blank...
Страница 10: ...viii OM131 Warnings P1939 OM 131 R11 Intentionally Blank...
Страница 12: ...x OM131 Table of Contents P1939 OM 131 R11 Intentionally Blank...
Страница 15: ...OM131 3 P1939 OM 131 R11 Chapter 1 Fig 1 1 SLS System Mk IV...
Страница 16: ...4 OM131 Chapter 1 P1939 OM 131 R11 Fig 1 2 SLS system layout...
Страница 32: ...20 OM131 Chapter 2 P1939 OM 131 R11 Fig 2 4 Two stage regulator Fig 2 5 Spool valve...
Страница 42: ...30 OM131 Chapter 2 P1939 OM 131 R11 Intentionally Blank...
Страница 53: ...OM131 41 P1939 OM 131 R11 Chapter 3 Fig 3 3 Hose Lanyards...
Страница 54: ...42 OM131 Chapter 3 P1939 OM 131 R11 Fig 3 4 SLS System Mk IV Rear View...
Страница 55: ...OM131 43 P1939 OM 131 R11 Chapter 3 Fig 3 5 SLS System Mk IV Front View...
Страница 64: ...52 OM131 Chapter 3 P1939 OM 131 R11 Intentionally Blank...
Страница 82: ...70 OM131 Chapter 4 P1939 OM 131 R11 Fig 4 7 Annual Maintenance Two Stage Regulator...
Страница 86: ...74 OM131 Chapter 4 P1939 OM 131 R11 Fig 4 8 Annual Maintenance Single Stage Regulator...
Страница 109: ...OM131 97 P1939 OM 131 R11 Chapter 5 Fig 5 2 Backpack Assembly Drawing P1939229S1...
Страница 111: ...OM131 99 P1939 OM 131 R11 Chapter 5 Fig 5 4 Scrubber Housing Assembly Drawing P1939131S1...
Страница 113: ...OM131 101 P1939 OM 131 R11 Chapter 5 Fig 5 6 SLS System Mk IV Inhale Exhale Duct Assembly Drawing P1939 DG 142...
Страница 115: ...OM131 103 P1939 OM 131 R11 Chapter 5 Fig 5 7 SLS System Mk IV Counterlung Duct Assembly Drawing P1939 DG 159...
Страница 118: ...106 OM131 Chapter 5 P1939 OM 131 R11 Fig 5 9 SLS System Mk IV Gas Schematic Drawing P193940S1...
Страница 123: ...OM131 111 P1939 OM 131 R11 Chapter 5 Fig 5 14 SLS System Mk IV Bottle Assembly...
Страница 125: ...OM131 113 P1939 OM 131 R11 Chapter 5 Fig 5 15 SLS System Rotowink General Assembly Drawing P1939 DG 59...
Страница 127: ...OM131 115 P1939 OM 131 R11 Chapter 5 Fig 5 16 SLS System Mk IV Hot Water System Drawing P1939156S1...
Страница 129: ...OM131 117 P1939 OM 131 R11 Chapter 5 Fig 5 18 Shroud Hot Water Hose Assembly Drawing P1939 DG 83282...
Страница 130: ...118 OM131 Chapter 5 P1939 OM 131 R11 Fig 5 19 SLS System Hot Water Shroud Assembly Drawing B82840...
Страница 132: ...120 OM131 Chapter 5 P1939 OM 131 R11 Fig 5 20 Refillable Canister Assembly Drawing P1939 DG 035...
Страница 133: ...OM131 121 P1939 OM 131 R11 Chapter 5 Fig 5 21 SLS System Mk IV Harness Assembly Drawing P1939137S1...
Страница 134: ...122 OM131 Chapter 5 P1939 OM 131 R11 Fig 5 22 SLS System Mk IV Actuation Cable Assembly Drawing P1939 DG 115...
Страница 135: ...OM131 123 P1939 OM 131 R11 Chapter 5 Fig 5 23 SLS System Mk IV Counterlung Assembly Drawing P1939 DG 56...