![Jeulin UT60A Скачать руководство пользователя страница 23](http://html2.mh-extra.com/html/jeulin/ut60a/ut60a_manual_3885553023.webp)
Measurement and instrumentation
Multimeter model UT60A
Réf :
291 033
ENGLISH
22
Remarks:
•
Continuity Test (400.0
Ω
) Range Buzzer beeps continuously.
•
Open circuit voltage approximate 0.45V
Diode Range:
•
Open circuit voltage approximate 1.48V
•
Displays approximate forward voltage drop reading 0.5V – 0.8V
•
400
Ω
– 40M
Ω
Range: Open circuit voltage approximate 0.45V
Capacitance
Range
Resolution Accuracy Overload Protection
40nF 10pF
400n F
100pF
4µF
10nF
±
(3%+5)
100µF 100nF
±
(4%+5)
600Vp
Frequency & Duty
Cycle
Range
Resolution Accuracy Overload Protection
10Hz-
10MHz
N/A
±
(0.1%+3)
0.1%-
99.9%
(Duty cycle)
0.01% N/A
600Vp
DC Current
Range Resolution Accuracy
Overload
Protection
400µA 0.1µA
4000µA 1µA
40mA 0.01mA
400mA 0.1mA
±
(1%+2)
±
(1.2%+3)
0.5A, 250V,
fast type Glass
fuse,
Ø5x20mm
4A 0.001mA
10A 0.1A
±
(1.5%+5)
10A, 250V,
fast type Glass
fuse,
Ø 5x20mm