Anschlussbeschreibung X5,6 USB2.0 Ports

 

 

1 VCC  (900 mA  max.) 

2 Data- 

3 Data+ 

4 GND  (Versorgung) 

 
 

Anschlussbeschreibung X4 USB3.0 Port 

 

USB2.0 

USB3.0 

1 VCC  (900 mA 
max.) 

5 StdA_SSRX- 

2 Data- 

6 St 

3 Data+ 

7 GND_DRAIN 

4 GND  (Versorgung)  8 StdA_SSTX- 

 

9 St 

 

 
 
 

 
 

 

Anschlussbeschreibung X2,3 Ethernet (RJ-45)

 

linke LED

rechte LED

 

1 MDI0+ 

2 MDI01 

3 MDI1+ 

4 MDI2+ 

5 MDI2- 

6 MDI1- 

7 MDI3+ 

8 MDI3- 

LED Statusanzeige 

Linke LED   

Rechte LED 

AUS 

Keine Verbindung 

AUS 

10 Mbit/s 

Grün,  dauernd 

Verbindung  OK 

Grün,  dauernd  100 Mbit/s 

Grün,  blinkend 

Verbindung  OK mit 
Datenverkehr 

Gelb,  dauernd  1.000 Mbit/s 

 

Содержание JI-FPC1015

Страница 1: ...50 444 Installationsanleitung Version 1 00 Artikel Nr 60884758 November 2019 Printed in Germany Abbildung hnlich Find english version below Lieferumfang 1 x JI FPC1015 Flatpanel PC 1 x Montagezubeh r...

Страница 2: ...Ma e Jetter JI FPC1015...

Страница 3: ...abel Lassen Sie mindestens 5cm Freiraum r ckseitig um das Ger t herum damit eine entsprechende Luftzirkulation stattfinden kann Ausschnittma 398mm x 282mm Empfohlene Wandst rke f r korrekten Sitz 1 5m...

Страница 4: ...gsvorrichtung montiert werden Das Ger t kann gedreht werden um die Bildschirmausrichtung im Quer oder Hochformat zu erm glichen Mindestabst nde Um eine ausreichende Luftzirkulation zu gew hrleisten m...

Страница 5: ...Schalter 4 X5 6 2 x USB 2 0 9 LED Aktivit t Massenspeicher 5 X7 1 x COM1 RS 232 10 LED Power 11 Erdungsbolzen Symbol Anschlussbeschreibung X1 Spannungsversorgung 2 3 1 1 Phoenix Stecker 3 polig 4 Klem...

Страница 6: ...to Send 8 CTS Clear to Send 9 RI Ring Indicator Anschlussbeschreibung X9 DisplayPort 1 ML Lane 0 p 2 GND ML Lane 0 3 ML Lane 0 n 4 Lane 1 p 5 GND ML Lane 1 6 Lane 1 n 7 Lane 2 p 8 GND ML Lane 2 9 Lane...

Страница 7: ..._SSRX 3 Data 7 GND_DRAIN 4 GND Versorgung 8 StdA_SSTX 9 StdA_SSTX Anschlussbeschreibung X2 3 Ethernet RJ 45 linke LED rechte LED 1 MDI0 2 MDI01 3 MDI1 4 MDI2 5 MDI2 6 MDI1 7 MDI3 8 MDI3 LED Statusanze...

Страница 8: ......

Страница 9: ...de Germany Phone Hotline 49 0 7141 2550 444 Installation Manual Revision 1 00 Item 60884758 November 2019 Printed in Germany Similar picture Scope of delivery 1 x JI FPC1015 Flatpanel PC 1 x Mounting...

Страница 10: ...Physical dimensions Jetter JI FPC1015...

Страница 11: ...ut for mounting to a wall panel W x H mm 312mm x 250mm Thickness of the mounting wall panel for proper mounting mm 1 5mm 6mm Clamp with screws for mounting the FusionClient to a wall panel 8 x Require...

Страница 12: ...alled operating system supports this feature Ensure that the length of the cable connections to power and peripherals are sufficient for this operating position Minimum spacing Leave at least 5 cm app...

Страница 13: ...8 Power button 9 X5 6 2 x USB 2 0 9 LED storage activity 10 X7 1 x COM1 RS 232 10 LED Power 11 Grounding stud and symbol X1 Power supply 2 3 1 1 3 pin Phoenix plug terminal 4 Shield terminal 2 Cover p...

Страница 14: ...to Send 8 CTS Clear to Send 9 RI Ring Indicator X9 Display port 1 ML Lane 0 p 2 GND ML Lane 0 3 ML Lane 0 n 4 Lane 1 p 5 GND ML Lane 1 6 Lane 1 n 7 Lane 2 p 8 GND ML Lane 2 9 Lane 2 n 10 Lane 3 p 11...

Страница 15: ...A_SSRX 3 Data 7 GND_DRAIN 4 GND ground for power return 8 StdA_SSTX 9 StdA_SSTX X2 X3 Ethernet RJ 45 1 MDI0 2 MDI01 3 MDI1 4 MDI2 5 MDI2 6 MDI1 7 MDI3 8 MDI3 LED states Left LED Right LED OFF Link not...

Страница 16: ......

Отзывы: