3.7
Control terminals
Step
Action
Comment
1
1
.
.
Connect terminal X3 of the supply unit to terminal
X3 of the first servo amplifier. Then connect termi
-
nal X4 of the first servo amplifier to X3 of the next
servo amplifier, etc.
Cross communication
2
2.
Establish a connection between the EtherCAT
interface X5.1 of the first servo amplifier and the
Motion Control controller or another compatible
controller.
Specification EtherCAT interface
3
3.
Connect all other servo amplifiers to the first servo
amplifier via the EtherCAT interfaces X5.1 and
X5.2
Specification EtherCAT interface
4
4
.
.
Wire the control inputs to X6 with shielded cables
as required.
Ground the cable shields with the greatest pos-
sible surface area on both sides.
5
5.
If you want to use the safety function STO and/
or STB, wire the safe control inputs to X11 with
shielded cables.
Ground the cable shields with the greatest pos-
sible surface area on both sides.
6
.
.
Check all connections again!