Installation Instructions Jetmaster 850 Gas Log 

L O G S

Only use logs supplied 
by the manufacturer as
other logs may effect
combustion performance.

5 . L O C AT E   L O G   N O. 6 .

Place this log on the right hand

side of the burner on the rear log in front of the pilot. Charred end

facing inwards. The left hand side of the log is positioned between

the metal uprights on the side of the grate.

LOCATE LOG NO. 7.

The charred effect of the log is

positioned on the smaller coal in the centre of the burner on the

right hand side.

LOCATE LOG NO. 8.

This smaller log is placed on the top of

log NO. 2 and rests on the left hand coal in the centre of the

burner.

6 . L O C AT E   L O G   N O. 9 .

This log is placed on the rear

log in the centre of the burner. Charred effect facing toward the left

of the burner.The front rests on logs 2 & 3 on the join.

LOCATE LOG NO. 10.

This log is located on the rear log in

the position where the log reduces in height. The charred end is

located on the front log 3 with the charred effect facing toward the

right hand side.

4 . LOCATE LOG NO. 4.

Place it on the left side of the

rear log. Charred end facing inwards.

LOCATE LOG NO. 5.

This log is placed with the thinner edge

on the smaller coal. The charred effect is facing towards the front

of the burner.The whole log is positioned on the burner base.

P O S I T I O N I N G   O F  

A L L   L O G S

• It is important to follow the log recommended 

positioning.

• Log NO. 6, 10, 9 and 4 must be pinned to rear log 

with pins provided.

• Not doing so can adversely effect the operation of 

the appliance.

• This diagram shows the recommended log 

positions, when viewed from above.

Содержание UNIVERSAL 850

Страница 1: ...Installation Instructions Jetmaster 850 Gas Log ...

Страница 2: ...mum chimney flue height of 3 6 meters The installer must satisfy himself that the fireplace is functioning properly and a smoke test is recommended 3 In cases where a twin walled metal flue is used and provided such flue shall comply with the clearances specified in AS 2918 and AS5601 or manufacturer instructions in respect of clearances to combustibles 4 A space of 40mm between the side wall of t...

Страница 3: ... control knob on right hand side of valve Depress and turn control knob FIG 1 to the PILOT position FIG 4 Depress the control button and ignite with piezo ignitor FIG 2 whilst keeping control knob firmly depressed for 20 seconds Check that pilot stays lit If it goes out repeat ignition procedure MAIN BURNER IGNITION Depress and turn control knob anti clockwise from PILOT position to the ON positio...

Страница 4: ... the underside to position in place 3 LOCATE LOG NO S 2 3 Two front log NO S 2 3 are supplied to fit into the space between the metal frame and the ceramic base These logs do not cover the front burner ports but are designed to deflect the front flame back into the fire L O G S P O S I T I O N I N G O F A L L L O G S It is important to follow the log recommended positioning Log NO 6 10 9 and 4 mus...

Страница 5: ...he centre of the burner Charred effect facing toward the left of the burner The front rests on logs 2 3 on the join LOCATE LOG NO 10 This log is located on the rear log in the position where the log reduces in height The charred end is located on the front log 3 with the charred effect facing toward the right hand side 4 LOCATE LOG NO 4 Place it on the left side of the rear log Charred end facing ...

Страница 6: ... with a slightly blue flame After approximately 20 minutes the fire will settle down and burn with a yellow flame 3 As with all gas appliances your gas log fire should be regularly serviced We recommend once each year Contact your nearest Jetmaster authorised agent to provide service The routine for an authorised person to follow has been set out in an attached leaflet 4 PLEASE NOTE Only logs prov...