Installation:
Fitting the Gas Grate

1. Check unit is suitable for intended gas supply.

2. The position of the gas control and inlet is on the right hand
side and is 3/8" B.S.P. female connection for L.P.G. A 1/2" regulator
is supplied when fitting to natural gas. Check that the chimney is
clear prior to fitting.

3. In an existing fireplace or Jetmaster firebox (if being used) drill
a 15mm hole through the right hand side of the fireplace(as you
face it) at a point of 85mm from the base and 85mm from the rear
wall(if providing stop cock in firebox).85mm from front wall (if stop
cock is outside firebox).

4. Cut and debur both ends of pipe. Fit the end to the gas supply
point and turn on for approximately 5 seconds to clear the pipe of
any dirt or grit. Fit the other end to the gas unit.

5. The regulator is included on the S.I.T. control on the unit.

6. Turn on the gas and check all connections for leaks using soapy
water or approved method. Fix any leaks.

7. Possible carbon deposition may occur on the appliance
incorporating live fuel effect.

Adjusting Pressure, Pilot 
and Low Fire

1. All settings are set to operate at appropriate pressures (see data
plate)

.

Test point is located on gas valve.

2. Check low fire if adjusted correctly.

3. The pressure can be measured on the gas valve and the
regulator adjusted to the appropriate pressure (see data plate
affixed to side of the appliance.)

Lighting Instructions

PILOT FLAME IGNITION 

Locate control knob on right hand side of valve. Depress and turn
control knob 

(FIG 1) 

to the    

PILOT position 

(FIG 4).

Depress

the control button and ignite with piezo ignitor 

(FIG 2) 

whilst

keeping control knob firmly depressed for 20 seconds. Check that
pilot stays lit. If it goes out repeat ignition procedure.

MAIN BURNER IGNITION

Depress and turn control knob anti-clockwise from     PILOT 
position to the     ON position 

(FIG 5).

The burner will not 

ignite if the rocker switch is depressed in the OFF position 

(FIG 3).

To light main burner press rocker switch to ON position 

(FIG 3).

TO TURN MAIN BURNER OFF WITH PILOT 
REMAINING BURNING

Depress rocker switch to OFF position.

(FIG 3)

Main burner can also be turned off by the use of control knob.This
is done by turning control knob clockwise to    

PILOT position

(FIG 8).

Control knob will need to be turned back to     ON

position 

(FIG 5) 

to light main burner.

TO TURN MAIN BURNER OFF OR ON WITH 
OPTIONAL WALL  SWITCH

Pilot must be burning.
Control knob is in the         ON position.

(FIG 5)

Rocker switch is in the OFF position.

(FIG 3)

Wall switch can now be activated.

Important! Wall switch can only be activated if rocker switch is in
off position.

TO TURN PILOT AND MAIN BURNER OFF

Depress and turn control knob clockwise from 

ON position 

(FIG 5) 

or     PILOT position (FIG 4) to the

OFF position 

(FIG 6).

TO TURN MAIN BURNER HIGHER OR LOWER

Turn high / low flame knob to obtain high or low fire 

(FIG 7)

.

Installation Instructions Jetmaster 850 Gas Log 

Fig 1

Control knob

Fig 2

Pietzo Igniter

Fig 3

Rocker Switch

Fig 6

clockwise  

Fig 5

an

ti clockwise  

Fig 4

an

ti clockwise  

Low flame

High flame

High / Low
flame knob

Fig 7

Fig 8

clockwise  

Содержание UNIVERSAL 850

Страница 1: ...Installation Instructions Jetmaster 850 Gas Log ...

Страница 2: ...mum chimney flue height of 3 6 meters The installer must satisfy himself that the fireplace is functioning properly and a smoke test is recommended 3 In cases where a twin walled metal flue is used and provided such flue shall comply with the clearances specified in AS 2918 and AS5601 or manufacturer instructions in respect of clearances to combustibles 4 A space of 40mm between the side wall of t...

Страница 3: ... control knob on right hand side of valve Depress and turn control knob FIG 1 to the PILOT position FIG 4 Depress the control button and ignite with piezo ignitor FIG 2 whilst keeping control knob firmly depressed for 20 seconds Check that pilot stays lit If it goes out repeat ignition procedure MAIN BURNER IGNITION Depress and turn control knob anti clockwise from PILOT position to the ON positio...

Страница 4: ... the underside to position in place 3 LOCATE LOG NO S 2 3 Two front log NO S 2 3 are supplied to fit into the space between the metal frame and the ceramic base These logs do not cover the front burner ports but are designed to deflect the front flame back into the fire L O G S P O S I T I O N I N G O F A L L L O G S It is important to follow the log recommended positioning Log NO 6 10 9 and 4 mus...

Страница 5: ...he centre of the burner Charred effect facing toward the left of the burner The front rests on logs 2 3 on the join LOCATE LOG NO 10 This log is located on the rear log in the position where the log reduces in height The charred end is located on the front log 3 with the charred effect facing toward the right hand side 4 LOCATE LOG NO 4 Place it on the left side of the rear log Charred end facing ...

Страница 6: ... with a slightly blue flame After approximately 20 minutes the fire will settle down and burn with a yellow flame 3 As with all gas appliances your gas log fire should be regularly serviced We recommend once each year Contact your nearest Jetmaster authorised agent to provide service The routine for an authorised person to follow has been set out in an attached leaflet 4 PLEASE NOTE Only logs prov...