JETMASTER UNIVERSAL - General Installation Instructions
CONTENTS
JETMASTER UNIVERSAL - Unit Specifications ...................................................... 1
Summary of Minimum Jetmaster Installation Specs ..........................................2 - 3
Jetmaster Installation into an Existing Fireplace ..................................................... 4
OPEN WOOD JETMASTER - Minimum Flue Height ............................................... 5
Construction Specifications - Jetmaster Traditional Victorian ................................. 6
Construction Specifications - Jetmaster Brick Veneer Installation ......................... 7
Construction Specifications - Jetmaster Installation Using Hebel .......................... 8
Construction Specifications - Jetmaster Traditional Space Saver .......................... 9
Construction Specifications - Jetmaster Traditional Edwardian On Stud Wall ..... 10
Construction Specifications - Jetmaster Free Standing Metal Casing ................. 11
Construction Specifications - Jetmaster Double Sided ........................................ 12
Open Gas Jetmaster .......................................................................................13 - 14
OPEN GAS FIREPLACE - Minimum Flue Height ................................................... 15
Open Gas Jetmaster .......................................................................................16 - 17
ASSEMBLY AND INSTRUCTION
• Position unit on finished hearth level - ensure air intake at base of unit is not obstructed;
• Bolt gather to unit;
• Insulate entire unit and gather where painted red;
• Bolt Lintel (optional) to unit - insulate between unit and Lintel;
• Rivet inner flue to collar of gather at three places;
• Rivet all further inner flues at three places;
• If using double skin flues space inner and outer flues using 3 x 25mm self tapping screws through outer casing at
bottom, at each join and at top. Also ensure that flues are ventilated at top and bottom, and when using a cover cone
drill a series of holes into the outer flue below the cover cone to ensure adequate ventilation
• Fit cowl to flue or chimney breast.
RECOMMENDATIONS
• Do not recess unit by more than 110mm
• Use a minimum of 3.6 metres lengths of flue
JETMASTER UNIVERSAL
DIMENSIONS IN MILLIMETRES
Heating capacity
Cu. Meters
MODEL
A
A1
B*
C
D
E
Wood
440
470 510 330 610 200 200
75
500
570 600 350 650 200 200
85
600
670 700 350 650 200 200
100
600 LOW
670 700 350 600 200 200
100
700 SH
770 800 350 650 200 200
130
700 SH LOW
770 800 350 600 200 200
130
700 SH LOW LOW
†
770 800 350 550 200 200
130
700D
770 800 400 700 225 200
160*
850
920 950 450 750 250 220
180
850 LOW
920 950 450 700 250 220
180
850 LOW LOW
920 950 450 650 250 220
180
1050
1120 1150 500 800 300 240
220
1200
1250 1300 605 1020 405 400
300
1200
double spigot
1250 1300 605 1020 250** 400
300
1500
1550 1600 605 1020 455 400
350
1500
double spigot
1550 1600 605 1020 300** 400
350
*Tested to 15Kw at maximum burning.** Requires 2 flue outlets (single flue option also available)
† Wood only
JETMASTER DOUBLE-SIDED
DIMENSIONS IN MILLIMETRES
Heating capacity
Cu. Meters
MODEL
A
B
C
D
E
F
Wood
700
850 800 610 700 220 300
200
1050
1205 1150 610 770 233 455
300
JETMASTER FREESTANDING
DIMENSIONS IN MILLIMETRES
Heating capacity
Cu. Meters
MODEL
A
B
C
D
Wood
600
1000 390 840 200
160
700 SH
1050 390 840 200
180
700D
1100 440 940 225
200
850
1200 490 990 250
240
1050
1400 550 1005 300
280
F