JETMASTER UNIVERSAL - General Installation Instructions

CONTENTS

JETMASTER UNIVERSAL - Unit Specifications ...................................................... 1

Summary of Minimum Jetmaster Installation Specs ..........................................2 - 3

Jetmaster Installation into an Existing Fireplace ..................................................... 4

OPEN WOOD JETMASTER - Minimum Flue Height ............................................... 5

Construction Specifications - Jetmaster Traditional Victorian ................................. 6

Construction Specifications - Jetmaster Brick Veneer Installation ......................... 7

Construction Specifications - Jetmaster Installation Using Hebel .......................... 8

Construction Specifications - Jetmaster Traditional Space Saver .......................... 9

Construction Specifications - Jetmaster Traditional Edwardian On Stud Wall ..... 10

Construction Specifications - Jetmaster Free Standing Metal Casing ................. 11

Construction Specifications - Jetmaster Double Sided ........................................ 12

Open Gas Jetmaster .......................................................................................13 - 14

OPEN GAS FIREPLACE - Minimum Flue Height ................................................... 15

Open Gas Jetmaster .......................................................................................16 - 17

ASSEMBLY AND INSTRUCTION

•  Position unit on finished hearth level - ensure air intake at base of unit is not obstructed;
•  Bolt gather to unit;
•  Insulate entire unit and gather where painted red;
•  Bolt Lintel (optional) to unit - insulate between unit and Lintel;
•  Rivet inner flue to collar of gather at three places;
•  Rivet all further inner flues at three places;
•  If using double skin flues space inner and outer flues using 3 x 25mm self tapping screws through outer casing at 

bottom, at each join and at top. Also ensure that flues are ventilated at top and bottom, and when using a cover cone 

drill a series of holes into the outer flue below the cover cone to ensure adequate ventilation

•  Fit cowl to flue or chimney breast.

RECOMMENDATIONS

•  Do not recess unit by more than 110mm
•  Use a minimum of 3.6 metres lengths of flue

JETMASTER UNIVERSAL

DIMENSIONS IN MILLIMETRES

Heating capacity

Cu. Meters

MODEL

A

A1

B*

C

D

E

Wood

440

470 510 330 610 200 200

75

500

570 600 350 650 200 200

85

600

670 700 350 650 200 200

100

600 LOW

670 700 350 600 200 200

100

700 SH

770 800 350 650 200 200

130

700 SH LOW

770 800 350 600 200 200

130

700 SH LOW LOW

770 800 350 550 200 200

130

700D

770 800 400 700 225 200

160*

850

920 950 450 750 250 220

180

850 LOW

920 950 450 700 250 220

180

850 LOW LOW

920 950 450 650 250 220

180

1050

1120 1150 500 800 300 240

220

1200

1250 1300 605 1020 405 400

300

1200 

double spigot 

1250 1300 605 1020 250** 400

300

1500

1550 1600 605 1020 455 400

350

1500 

double spigot

1550 1600 605 1020 300** 400

350

*Tested to 15Kw at maximum burning.** Requires 2 flue outlets (single flue option also available)

† Wood only

JETMASTER DOUBLE-SIDED

DIMENSIONS IN MILLIMETRES

Heating capacity

Cu. Meters

MODEL

A

B

C

D

E

F

Wood

700

850 800 610 700 220 300

200

1050

1205 1150 610 770 233 455

300

JETMASTER FREESTANDING

DIMENSIONS IN MILLIMETRES

Heating capacity

Cu. Meters

MODEL

A

B

C

D

Wood

600

1000 390 840 200

160

700 SH

1050 390 840 200

180

700D

1100 440 940 225

200

850

1200 490 990 250

240

1050

1400 550 1005 300

280

F

Содержание UNIVERSAL 440

Страница 1: ...ION INSTRUCTIONS JETMASTER VIC PTY LTD ACN 005 872 159 ABN13 659 821 337 444 Swan St Richmond VIC 3121 PO Box 5051 Burnley 3121 Phone 03 9429 5573 Fax 03 9427 0031 Website www jetmastervic com au Emai...

Страница 2: ...Specifications Jetmaster Brick Veneer Installation 7 Construction Specifications Jetmaster Installation Using Hebel 8 Construction Specifications Jetmaster Traditional Space Saver 9 Construction Speci...

Страница 3: ...Heating capacity Cu Meters MODEL A A1 B C D E Wood 440 470 510 330 610 200 200 75 500 570 600 350 650 200 200 85 600 670 700 350 650 200 200 100 600 LOW 670 700 350 600 200 200 100 700 SH 770 800 350...

Страница 4: ...be minimum 100mm thick This includes selected finish such as ceramic tiles marble or granite Must project forward of aperture by a minimum of 300mm Must project either side of aperture by a minimum of...

Страница 5: ...tapping screws through outer casing at bottom at each join and at top Also ensure that flues are ventilated at top and bottom and when using a cover cone drill a series of holes into the outer flue b...

Страница 6: ...ney If the height is too low remove the lintel and replace it at the required height Step 2 Check that your chimney is clean and free from obstructions From the measurements taken select the size of y...

Страница 7: ...fing materials any other combustible materials Flashing OPEN WOOD JETMASTER Minimum Flue Height Ridge Line Rotating Cowl Hearth Flue Termination The minimum flue length is 3 6 metres or above the ridg...

Страница 8: ...6 Construction Specifications Jetmaster Traditional Victorian...

Страница 9: ...7 Models 400 to 700D 26mm Models 850 to 1500 100mm FREE ROTATING COWL Construction Specifications Jetmaster Brick Veneer Installation...

Страница 10: ...8 Construction Specifications Jetmaster Installation Using Hebel Models 400 to 700D 26mm Models 850 to 1500 100mm...

Страница 11: ...9 Construction Specifications Jetmaster Traditional Space Saver Models 400 to 700D 26mm Models 850 to 1500 100mm Models 400 to 700D 26mm Models 850 to 1500 100mm...

Страница 12: ...10 Construction Specifications Jetmaster Traditional Edwardian On Stud Wall...

Страница 13: ...master allow 350mm minimum rafters Outer flue must be ventilated Side of firebox to edge of hearth minimum 200mm 12mm fibre cement sheet one course of brick Front of firebox to edge of hearth minimum...

Страница 14: ...el to recess firebox by maximum of one brick important allow 2mm expansion selected tile finish 12mm fibre cement sheet concrete hearth min 100mm high do not obstruct air intake raise firebox to level...

Страница 15: ...nce Do not block or restrict chimney or flue opening After installing the appliance check that the chimney flue system draws well Jetmaster recommends that all gas fires be serviced every 2 years All...

Страница 16: ...en fires require fresh air vents as per Clause 6 10 9 5 in AS NZS5601 1 2013 One or more ventilation openings with a combined free ventilation area of not less than the equivalent cross sectional area...

Страница 17: ...horter than 3 5 metres Maintain a minimum of 500mm from the bottom of the flue cowl to the nearest part of the roof if the flue cowl is at least 1m from a neighbouring structure If less than 1m the fl...

Страница 18: ...t will depend on the type of wood used and the general weather conditions Experience will soon show you how far however the damper should never be closed more than half way 6 When the fire has gone ou...

Страница 19: ...ls 1 Medium density woods are preferred for open fireplaces Softer woods Pines etc burn fast leaving a lot of ash and creosote Hard woods Red Gum etc can be best used when mixed with medium woods and...

Страница 20: ...18 JM 120 07 18 Specifications subject to change contact Jetmaster prior to commencement...

Отзывы: