background image

Page 2

Install Guide

A. Design and Installation Considerations

Consideration must be given to:

Safety

Convenience

Traffic flow

Chimney and flue requirements

It is a good idea to plan your installation on paper, using
exact measurements for clearances and floor protection,
before actually beginning the installation. If you are not
using an existing chimney, place the appliance where there
will be a clear passage for a factory-built listed chimney
through the ceiling and roof.

We recommend that a qualified building inspector and your
insurance company representative review your plans
before and after installation.

If this appliance is in an area where children may be near
it is recommended that you purchase a decorative barrier
to go in front of the appliance. Remember to always keep
children away while it is operating and do not let anyone
operate this appliance unless they are familiar with these
operating instructions.

Check building codes prior to installation.

Installation MUST comply with local, regional,
state and national codes and regulations.

Consult insurance carrier, local building, fire
officials or authorities having jurisdiction about
restrictions, installation inspection, and permits.

CAUTION

NOTICE:

JETMASTER ASSUMES NO

RESPONSIBILITY FOR THE IMPROPER
PERFORMANCE OF THE APPLIANCE
SYSTEM CAUSED BY:

Inadequate draft due to environmental conditions

Down drafts

Tight sealing construction of the structure

Mechanical exhausting devices

Over drafting caused by excessive chimney heights

Ideal performance is with height of chimney
minimum 4.6 metres as per AS/NZS 2918:2018.

Negative

 

pressure

 

results

 

from

 

the

 

imbalance

 

of

 

air

 

available

 

for

 

the

 

appliance

 

to

 

operate

 

properly.

 

It

 

can

 

be

 

strongest

 

in

 

lower

 

levels

 

of

 

the

 

house.

Causes

 

include:

Exhaust fans (kitchen, bath, etc.)

Range hoods

Combustion air requirements for furnaces, water
appliances and other combustion appliances

Clothes dryers

Location of return-air vents to furnace or air
conditioning

Imbalances of the HVAC air handling system

Upper level air leaks such as:
-

Recessed lighting

-

Attic hatch

-

Duct leaks

B. Fire Safety

To provide reasonable fire safety, the following should be
given serious consideration:

1.

Install

 

at

 

least

 

one

 

smoke

 

detector

 

on

 

each

 

floor

 

of

your

 

home

 

to

 

ensure

 

your

 

safety.

 

They

 

should

 

be

located

 

away

 

from

 

the

 

heating

 

appliance

 

and

 

close

 

to

the

 

sleeping

 

areas.

 

Follow

 

the

 

smoke

 

detector

manufacturer’s

 

placement

 

and

 

installation

 

instructions,

and

 

be

 

sure

 

to

 

maintain

 

regularly.

2.

A

 

conveniently

 

located

 

Class

 

A

 

fire

 

extinguisher

 

to

contend

 

with

 

small

 

fires

 

resulting

 

from

 

burning

 

embers.

3.

A

 

CO

 

detector

 

should

 

be

 

installed

 

in

 

the

 

room

 

with

 

the

appliance.

4.

A

 

practiced

 

evacuation

 

plan,

 

consisting

 

of

 

at

 

least

 

two

escape

 

routes.

5.

A

 

plan

 

to

 

deal

 

with

 

a

 

chimney

 

fire

 

as

 

follows:

In

 

the

 

event

 

of

 

a

 

chimney

 

fire:

a.

Evacuate

 

the

 

house

 

immediately

b.

Notify

 

the

 

fire

 

brigade.

WARNING

Asphyxiation Risk.

Do NOT connect this appliance to a
chimney flue servicing another appliance.

Do NOT connect to any air distribution
duct or system.

May allow flue gases to enter the house.

1. Getting Started

C

.

Negative Pressure

Содержание 700 Double-sided

Страница 1: ...l only Other fuels may over fire and generate poisonous gases i e carbon monoxide Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do n...

Страница 2: ...1 6 General use Attaching firescreen lighting a fire 12 6 General use Fuels Cleaning Maintenance Safety 12 AS NZS 2918 2018 General notes Thank you for purchasing a Jetmaster fireplace Please read thi...

Страница 3: ...devices Over drafting caused by excessive chimney heights Ideal performance is with height of chimney minimum 4 6 metres as per AS NZS 2918 2018 Negative pressure results from the imbalance of air av...

Страница 4: ...uate flow of outdoor air for all combustion appliances and exhaust equipment Ensure cental heating and air conditioning return vents are not located in the vicinity of the appliance Avoid installing t...

Страница 5: ...ick welded steel it is normal and expected for some imperfections and slightly out of square components It is recommended to not begin construction of cavity or flue penetration points until after the...

Страница 6: ...as a reference only Due to the nature of thick welded steel it is normal and expected for some imperfections and slightly out of square components It is recommended to not begin construction of cavity...

Страница 7: ...tion Note Timber framing should be constructed using normal framing methods Image above is an example only Do not install finishing materials around the cavity until after the fireplace has been insta...

Страница 8: ...ector Hebel blocks must be used in front of the appliance base on both sides when installing the appliance see joint AS NZS 2918 2018 3 3 2 The floor protector should extend 500mm in front of each of...

Страница 9: ...wrapped in 100mm R3 5 insulation between the PowerPanel enclosure up to the height of 200mm above the top of the gather The Flue penetration through the ceiling must have a 50mm gap in all directions...

Страница 10: ...ation cap away from trees adjacent structures uneven roof lines and other obstructions Your local dealer is the expert in your geographic area and can usually make suggestions or discover solutions th...

Страница 11: ...ond length to have crimp facing down Fig 5 2 Glass tape may be required to ensure a snug fit The outer flue is then installed outside active flue with crimp facing up to ensure water penetration on fl...

Страница 12: ...side towards you with the steel handle provided 2 In firebox lay your fire lighters 10 to 15 centimetres apart depending on the size of your firebox Do not use newspaper as a fire lighter On units th...

Страница 13: ...S NZS 2918 General notes Fuels The quality of firewood is extremely important How long a tree has been felled or dead for does not indicate how dry the wood is The best way to dry wood is to split it...

Отзывы: