Page 4
2. Components and specifications
20MM
Gather must be securely bolted to the unit
Optional 3 and 4 sided 100mm surrounds are available. Add 100mm to B measurement for coverage
Fitting instructions on following page.
Gather
Single sided
Unit
MODEL
A
B
C
D
E
F
G
H
I
1200 single spigot gather
1250
1300
600
1000
400
400
260
485
225
1200 dual spigot gather
1250
1300
600
1000
400
250
300
450
150
1500 single spigot gather
1550
1600
600
1000
665
450
160
410
250
1500 dual spigot gather
1550
1600
600
1000
400
300
350
450
150
•
Measurements are in mm and provided as a reference only.
•
Double flue size is 50mm bigger than the above ‘F’ measurements.
•
Dual spigot will require twice the total flue quantity.
•
Due to the nature of thick welded steel, it is normal and expected for some imperfections and slightly out of square components. It is recommended to not
begin construction of cavity or flue penetration points until after the unit is in place on site.
•
1200 and 1500 single spigot gathers protrude well past the back of the firebox. Refer to page 7 and 8 for instructions clearance and cavity instructions.