background image

Page 3

D. Tools And Supplies Needed

Before beginning the installation be sure the following tools
and building supplies are available:

Reciprocating saw
Hand saw
Framing material pliers
High temp caulking material
Hammer
Gloves
Phillips screwdriver
Framing square 1/2-3/4 in.
length, #6 or #8 self-drilling screws
Touch up paint - Stove bright satin black

E. Inspection of Appliance and Components

Remove appliance and components from packaging and inspect for damage.

Report to your dealer any parts damaged in shipment.

Due to the nature of thick welded steel, it is normal and expected for some imperfections and slightly out of square components.
It is recommended to not begin construction of cavity or flue penetration points until after the unit is in place on site.

Surface scratches can and will occur during installation - it is normal to expect to touch these visible surfaces up with Stove Bright
Satin black. Deep scoring may require a light sand and respray. This is normal and not covered by warranty.

Read all the instructions before starting the installation. Follow these instructions carefully during the
installation to ensure maximum safety and benefit.

To minimize the effects of negative air pressure:

Ensure adequate flow of outdoor air for all
combustion appliances and exhaust equipment

Ensure cental heating and air conditioning return
vents are not located in the vicinity of the appliance

Avoid installing the appliance near doors, walkways
or small isolated spaces

Recessed lighting should be a “sealed can” design

Attic hatches weather stripped or sealed

Attic mounted duct work and air handler joints and
seams taped or sealed

Basement installations should be avoided

WARNING

Fire Risk.

JETMASTER VIC disclaims any responsibility
for, and the warranty will be voided by, the
following actions:

Installation and use of any damaged appliance.

Modification of the appliance.

Installation other than as instructed by
JETMASTER VIC.

Installation and/or use of any component part not
approved by JETMASTER VIC.

Operating appliance without fully assembling all
components.

Do NOT Over fire - If appliance or chimney
connector glows, you are over firing.

Any such action that may cause a fire hazard.

Flat blade screwdriver Electric drill and bits
Plumb line
Safety glasses
Level
Tape measure
Misc. screws and nails
10mm socket or wrench
R3.5 Fibreglass insulation (if required)
75mm Hebel Powerpanel (if required)

Fire Risk.

Inspect appliance and components for damage.
Damaged parts may impair safe operation.

Do NOT install damaged components.

Do NOT install incomplete components.

Do NOT install substitute components.

Report damaged parts to dealer.

WARNING

Содержание 1200 series

Страница 1: ...only Other fuels may over fire and generate poisonous gases i e carbon monoxide Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not...

Страница 2: ...11 6 General use Attaching firescreen lighting a fire 12 6 General use Fuels Cleaning Maintenance Safety 12 AS NZS 2918 2018 General notes Thank you for purchasing a Jetmaster fireplace Please read th...

Страница 3: ...is with height of chimney minimum 4 6 metres as per AS NZS 2918 2018 C Negative Pressure Negative pressure results from the imbalance of air available for the appliance to operate properly It can be...

Страница 4: ...flow of outdoor air for all combustion appliances and exhaust equipment Ensure cental heating and air conditioning return vents are not located in the vicinity of the appliance Avoid installing the a...

Страница 5: ...1500 dual spigot gather 1550 1600 600 1000 400 300 350 450 150 Measurements are in mm and provided as a reference only Double flue size is 50mm bigger than the above F measurements Dual spigot will r...

Страница 6: ...plications an AGA approved cowl must be used C D Measurements are in mm and provided as a reference only Due to the nature of thick welded steel it is normal and expected for some imperfections and sl...

Страница 7: ...GOT 1600 1730 750 1500 DOUBLE SPIGOT 1600 1730 690 Note Timber framing should be constructed using normal framing methods Image above is an example only Do not install finishing materials around the c...

Страница 8: ...ce see joint AS NZS 2918 2018 3 3 2 The floor protector should extend 900mm in front of the appliance opening and be placed centrally in the 1650mm width 100mm thick floor protector projection can con...

Страница 9: ...op of the appliance gather with 100mm R3 5 insulation compressed to 15mm between the appliance and Hebel PowerPanel Double spigot gather is narrower It is important to ensure Hebel cavity is within 15...

Страница 10: ...ation cap away from trees adjacent structures uneven roof lines and other obstructions Your local dealer is the expert in your geographic area and can usually make suggestions or discover solutions th...

Страница 11: ...crimp facing up to ensure water penetration on flue above roof runs out Rivet active flues together at crimped joins Fix outer non active flues to active inner flues use 3 x 25mm self tapping screws...

Страница 12: ...side towards you with the steel handle provided 2 In firebox lay your fire lighters 10 to 15 centimetres apart depending on the size of your firebox Do not use newspaper as a fire lighter On units th...

Страница 13: ...S NZS 2918 General notes Fuels The quality of firewood is extremely important How long a tree has been felled or dead for does not indicate how dry the wood is The best way to dry wood is to split it...