JETI model MEZON 90 Скачать руководство пользователя страница 20

EN

Acumulator type

 – 

Here is where you select your flight battery type:

NiCd/NiMh

 – 

the cut-off voltage can be set according to your desired minimum single 

cell voltage.

LiIon/LiPol

 – 

Here you can either allow your Mezon to automatically detect the number 

of cells (this is useful if you are using packs with different cell counts), or you can specify 
the number of cells. For LiFe packs we do not recommend the automatic cell selection, 
instead, you should specify the number of cells. The last setup choice within this cell type 
is the setting for the minimum voltage per cell.

Direct

  – 

Here  you  can  simply  enter  a  cut-off  voltage  directly  without  selecting  any 

battery type.

Alarm voltage

 – 

Here is where you set the alarm level where the low voltage alarm is 

activated.

Temp.  Protection

 – 

This is for the set-up of any temperature protection. If the ESC 

temperature exceeds the selected temperature protection value, the selected motor cut-
off starts and the high temperature alarm is activated. The temperature alarm starts 
signaling  when  the  ESC  temperature  is  10  degrees  below  the  selected  temperature 
protection value.

 

Max.  bat.  Capac.

  – 

Setting  for  the  maximum  flight  battery  capacity  usage.  If  the 

capacity used exceeds the selected value, the selected motor cut-off starts. It is possible to 
select NO LIMIT in this menu.

Capacity

 

alarm 

-   

Setting for the alarm activation level if battery capacity usage is 

exceeded.

Max. batt Current

 – 

Setting for the current protection. If the actual current draw exceeds 

the  selected  current  value,  the  Mezon  actively  limits  the  current  draw  and  the  high 
current alarm is activated .

Cutoff type

 – 

Motor power limiting mode.

19

Содержание MEZON 90

Страница 1: ...R O N I C S P E E D E L E C T R O N I C S P E E D CONTROLLER CONTROLLER FOR BRUSHLESS MOTOR FOR BRUSHLESS MOTOR E L E C T R O N I C S P E E D CONTROLLER FOR BRUSHLESS MOTOR Compatible with the DUPLEX...

Страница 2: ...gtheMEZONtothereceiver 10 3 5Batteryconnection disconnectionprocedure 11 3 6 Connecting the RPM output 12 4 ControllerSet Up 12 4 1ControllerSet UpMenu 13 4 2LimitsSet UpMenu 18 4 3MotorSet upMenu 20...

Страница 3: ...EN 2...

Страница 4: ...ure maximum supervision and diagnostics for your model This system in cooperation with the DUPLEX system gives the modeler much greater confidence and peace of mind Now you can easily monitor battery...

Страница 5: ...rview Both OPTO and BEC versions of the MEZON controller are available The MEZON controllersareofferedinawidespectrumfromtheMEZON90totheMEZON165Opto Fig 1 CircuitoftheMEZONControllerwithBEC Type Susta...

Страница 6: ...dservos Theincoming andoutgoingsignalsofOPTOcontrollershavenoelectricconnectiontothedrivebattery ConnectingpowertotheRPM outputisnotnecessary thisoutputreceivesitspowerfrom thethrottlechannelcurrentso...

Страница 7: ...llerhasrecognizedacorrectcontrolpulsewhichcomplieswiththeSTOP lowthrottle positionandispreparedtostartthemotor The controller has recognized an incorrect throttle control pulse Check the transmitterth...

Страница 8: ...oldering no bare cable is exposed out of the connector soldering cavity remove the cable insulation in the exact length correspondingtothecavitydepth 2 Heatupthebareendofthecablewith the soldering iro...

Страница 9: ...othefemalehalfofthe JetiAntiSpark connectorwhenyousoldieracabletothe female connector In this case the male plug will dissipate heat during soldering and ensure that the parts already solderedtothefem...

Страница 10: ...rforevery25cm 10 ofadditionalbatterycablelength 3 3 ConnectingtheMEZONtotheJETIBOX MEZONcontrollersareequippedwithtwo threewirecableswithJR typeservoplugs The cable with a black plug marked with an RX...

Страница 11: ...connectthered EXT plugtothe EXT portinaDUPLEXEXreceivertotransmit the MEZON controller telemetry data as well as for the wireless controller setup WhenconnectingaBECequippedversiondonotforgettoturnont...

Страница 12: ...Rx 3 5 Batteryconnection disconnectionprocedure ForthebatteryandcontrollerconnectionswerecommendtheuseoftheJETIMODELAnti SparkG5 5connectors WerecommendsolderingtheAntiSparkconnectortothepositive wire...

Страница 13: ...the chapter It is assumed that we always start from the controller introductiondisplay ThisisthefirstdisplayshownintheJETIBOXdisplaywhenyouturn onthecontroller BatteryConnectionMethod 1 Connect the c...

Страница 14: ...Measurement menu Min Max log Settings menu Controller Operation mode Normal Operation mode Fast response Operation mode Constant RPM Motor poles 14 Rotor gear 1 6 Set MaxRotor RPM 2000 RPM Set MinRoto...

Страница 15: ...speed SetMinRotorRPM Desiredminimumrotorspeed Gain Governor gain setting The higher this number the faster the throttle corrections A lower number is displayed If this setting is too high the throttle...

Страница 16: ...spool up up quickly when the throttle is restored release throttle hold This effectively creates a window just above the initializationpointwhichallowstheautorotationaccelerationto arm Acceleration Th...

Страница 17: ...engthof50 andduring1sthebrake strengthwillincrease stepbystep to100 HARD70 100 0 5s the brake starts with a strength of 70 and during 0 5s the brakestrengthwillincrease stepbystep to100 MANUALsetting...

Страница 18: ...the selected value is lowerthantheactualthrottlevalue thecontroller motorwillsoundanerrortone EndPoint Thisisthedefinedfullthrottlepositionvalue Note For safety reasons the Init Point and End Point ca...

Страница 19: ...off InthismenuyoucanSetlowvoltage motorcut offpointfortheflightbattery Youcanset boththecut offpointandthetypeofmotorcut off Acumulator type Direct Acumulator type Nicd NiMh Acumulator type Li Ion Po...

Страница 20: ...e low voltage alarm is activated Temp Protection This is for the set up of any temperature protection If the ESC temperatureexceedstheselectedtemperatureprotectionvalue theselectedmotorcut off starts...

Страница 21: ...rs MEZON 130 6 51V SBEC 6 15A Measurement menu Actual values Measurement menu Min Max log Setting menu Controller Setting menu Limits Rotation dir LEFT RIGHT Rotationdirection directionofmotorrotation...

Страница 22: ...the number of motor poles This parameter is important for the correctRPMspeeddetection Rotorgear enterthecorrectgearratio Fordirectdrives nogearbox select1 0 1 4 4 BEC Set upMenu MEZON 130 6 51V SBEC...

Страница 23: ...elemetrysystem Whenyoucombinethe Mezon controller and wireless DUPLEX transmission you get a complex power control systemwithcomprehensivedatasupervision 5 1Telemetry1stGeneration The actual measured...

Страница 24: ...ime BECVolt Current thismenushowstheBECvoltageandthecurrent beingconsumedbytheBEC Impulse PWMDuty displays the actual pulse width of the throttle channel and the voltage being consumed by the motor as...

Страница 25: ...MEZONOPTOcontrollermenu Max Speed maximumRPMwithmotorruntimelisted Calculatedfromthecontrollerstartpoint Min voltage Minimumbatteryvoltagewithmotorruntimelisted Calculatedfromthecontrollerstartpoint C...

Страница 26: ...rwhenreadingthemotorposition Ifnoerrorcodeshavebeentriggeredduringtheflight thedisplaywillshow 0 Remark protectionagainstcommutationerrors Sometimesaproblemoftoomany commutation errors due to the moto...

Страница 27: ...ter instructionbooklet StartthefirmwareupdateprogramonyourPC Connect the three wire cable with the red connector from the MEZON controller to the USB adapter As long as the controller is connected to...

Страница 28: ...otor off if the voltage shows an increasedresidualripple the controller might be overloaded and therefore limiting power or the motor is possiblystoppedduetointerventionoftheheatprotectioncircuit exce...

Страница 29: ...warranty claims Whensolderingconnectorsmakesurethatthesolderhasflowedproperlyandthatthe jointsareclean Bad solderingjoints especiallyatthemotor candestroythecontroller Suchacontrollercannotberepaireda...

Страница 30: ...ns as described in the manual i e at the specified voltageandwithoutanyapparentmechanicaldamages Whenclaimingwarrantyrepairs for a product always send along your purchase receipt Warranty claims are h...

Страница 31: ...EN 9 Disposal of Used Electronic Equipment 30...

Страница 32: ...115 opto 120 130 135 opto 160 165 opto Country of origin Czech republic The object of declaration described above is in conformity with the requirements of the folowing EU legislations and harmonized...

Страница 33: ...opto 115 opto 120 130 135 opto 160 165 opto Herstellungsland Czech republic F r die oben erw hnten Produkte aus unserem Hause gelten die einschl gigen und zwingenden EU Richtlinien Folgende Fachgrundn...

Страница 34: ...EN JETI model s r o Lomen 1530 742 58 P bor www jetimodel com Czech Republic EU...

Отзывы: