OPERATION MANUAL

Rain Detector DRD-12V

Connection

After removing the sensor cover, the control cable is to be inserted in 

the cable gland M16.

Supply voltage is to be connected to the terminals VCC and GND. 

Terminals NC, COM, NO are the potential free changeover contacts 

for switching.

Precautions:

• The device is suitable only for low voltages and should not be

operated on mains supply !

• The relay contact is only suitable for low value signals and

should not come in contact with mains supply !

• The protection type is valid only with an intact, complete casing,

cover screws and cable gland properly tightened, and the cover-

gasket should always be available on the sensor cover !

• The suitability for certain applications is to be checked by the

user

Settings

Signal generator output (optional)

At the connection terminals (Pin BUZ and GND) a passive Piezo 

signal generator can be connected. The condition of signal (acustic 

signal for dry or wet) can be selected with the plug links S1-S2 or 

S2-S3. In the default-position S2-S3, the signal generator is inactive 

for rain.

Switching mode

The switching mode of the relay (pickup or dropout with rain) can be 

selected with the plug links T1-T2 or T2-T3. In the factory settings, 

link T1-T2 is connected and the relay closes if the sensor surface 

gets wet.

Heating

The sensor surface is heated, if the link of HZ1-HZ2 is connected. To 

ensure faster drying and for operation below freezing point, the 

heater should be switched on. For sensing fog, the heater can be 

switched off.

Sensitivity setting

The sensitivity for detecting rain can be adjusted with the potentiometer

“SENS”. Rotating the potentiometer clockwise results a higher sensitivity

For direction rain mostly the middle position of the potentiometer is suitable

Please note that no function takes place in the end position!

Indicators

There is a green LED on the device to indicate the operation status 

and a red LED to indicate the switch position (meansrelay contact 

closed).

Maintenance

The Rain Sensor unit is almost maintenance free. The sensor surface 

must be occasionally cleaned with a moist cloth ( e.g. once annually, 

depending on the place of installation). In case of persistent condi-
tion, even if it does not rain, it triggers due to strong contamination.

Connection Layout

REL NC 

Opening switch contact

REL NO 

Closing switch contact

REL CO 

Common switch contact

AC/DC

Operating voltage AC or 24 V DC +10%

AC/GND

Operating voltage AC or 0 V

1

Switch mode signal generator (dry)

2

Common contact to S3 and S1

3

Switch mode signal generator (wet)

4

Signal generator ground

5

Signal generator output

6

Switch mode relay (dry)

7

Common contact to T3 and T1

8

Switch mode relay (wet)

9

Heating

10

Heating

11-16 not occupied

Dimensions

Attention

Please avoid extreme mechanical and inappropriate exposure.
The device/product is not suitable for potential explosive areas and 
medical-technical applications.

issueC/20220

908

/V

4