3.5. Fitting the pump
Pump installation and assembly must be carried out
by an authorised installer.
A) General safety warnings.
The equipment must be fitted following
current safety regulations for installing
swimming pools, and particularly standard
IEC 60364-7-702 and the special regulations
for each application.
The pump must be installed on a flat surface
and attached to the floor.
The mains electricity supply must be
protected by an automatic power-supply cut-
out device, a residual current circuit-breaker
switch ( fn) not exceeding 30 mA.
B) Fitting the pipes
The connection pipes to the pump for
distances of up to 3.5 metres must have a
minimum diameter of DN63.
Flow valves must be fitted in the discharge
and suction pipes, so that the pump can be
removed for maintenance without draining
the swimming pool.
Electrical installation most have a multiple
separation system with at least 3mm contact
separation.
ALWAYS USE MULTIPLE SUCTION
OUTLETS.
If the fitting/cover breaks, is damaged, or is
missing, shut the system down immediately .
Do not use the system until the covers have
been replaced.
Particular care must be paid to ensure that
water cannot enter the pump motor or other
electrically powered parts of the installation.
The premises in which the pump is installed
must comply with the complementary
technical safety instructions applicable to
damp or wet premises.
The premises must be provided with a drain
that allows water to be evacuated in the event
of flooding of the premises that might be
detrimental to electrical safety and cause
injury to persons.
For optimum pump operation and reliability
the premises must be provided with a
ventilation inlet.
The installation pipes and accessories must
be made of PVC. Under no circumstances
must iron pipes or accessories be used, as
they could damage the plastic components of
the installation.
!
!
!
!
!
!
!
!
Flow valves
29
129033 JET NCB.qxd 10/2/06 15:43 Página 12
Содержание NCB
Страница 11: ...7 DIMENSIONESYPESOS 120 120 170 Peso 1Kg 11 129033 JET NCB qxd 10 2 06 15 43 Página 22 ...
Страница 22: ...7 DIMENSIONS ET POIDS 120 120 170 Poid 1Kg 22 129033 JET NCB qxd 10 2 06 15 43 Página 28 ...
Страница 33: ...7 DIMENSIONSAND WEIGHTS 120 120 170 Weight 1Kg 129033 JET NCB qxd 10 2 06 15 43 Página 4 33 ...
Страница 34: ...129033 JET NCB qxd 10 2 06 15 43 Página 4 34 ...
Страница 35: ...129033 JET NCB qxd 10 2 06 15 43 Página 4 35 ...
Страница 36: ...129033 JET NCB qxd 10 2 06 15 43 Página 4 Cod 129033 02 2011 02 ...