Do not operate the machine under the 
influence of drugs, alcohol or any 
medication. Be aware that medication 
can change your behaviour.  

Keep children and visitors a safe 
distance from the work area. 

Never leave a running machine 
unattended. Before you leave the 
workplace switch off the unit. 

Do not operate the electric tool near 
inflammable liquids or gases. 
Observe the fire fighting and fire alert 
options, for example the fire 
extinguisher operation and place. 

Do not use the dust collector in a 
dump environment and do not expose 
it to rain. 

Do not use this equipment to filter 
volatile fumes or smoke. 

Wood dust is explosive and can also 
represent a risk to health. 
Dust form some tropical woods in 
particular, and from hardwoods like 
beach and oak, is classified as a 
carcinogenic substance. 

Connection and repair work on the 
electrical installation may be carried 
out by a qualified electrician only. 

Have a damaged or worn power cord 
replaced immediately. 

 

3.3 Remaining hazards 

When using the machine according to 
regulations some remaining hazards 
may still exist. 

Dust can cause injuries. 

The use of incorrect mains supply or a 
damaged power cord can lead to 
injuries caused by electricity. 

Danger of explosion if not properly 
grounded. 

 

4.  Machine specifications 

4.1 Technical data 

Dust inlet 

Ø 150mm (2xØ 100mm) 

Air flow Ø 150 

1620 m³/h 

Air flow Ø 100  

1150 m³/h 

Vacuum pressure 

1700Pa 

Collector bag capacity 

200L 

Overall DC-1100A: 
(LxWxH) 

940x510x2000mm 

Net weight 

48 kg 

Overall DC-1100CK: 
(LxWxH) 

940x510x1830mm 

Net weight 

71 kg 

Mains 

230V ~1/N/PE  50Hz 

Output power 

1,1kW (1,5HP) S1 

Reference current 

4.8 A 

Extension cord (H05VV-F) 3Cx1.5mm² 
Installation fuse protection 

10A 

Mains 

400V ~3L/PE  50Hz 

Output power 

1,1kW (1,5HP) S1 

Reference current 

2 A 

Extension cord (H05VV-F) 4Cx1.5mm² 
Installation fuse protection 

10A 

 

4.2 Noise emission 

Acoustic pressure level  
(EN ISO 11202):   

LpA  80 dB(A). 

The specified values are emission 
levels and are not necessarily to be 
seen as safe operating levels. 
As workplace conditions vary, this 
information is intended to allow the 
user to make a better estimation of the 
hazards and risks involved only. 

 

4.3 Content of delivery 

Filter bag (DC-1100A) 
Canister filter (DC-1100CK) 
Mobile casters 
Cone support bracket 
Cone 
Dust inlet 2 x 100 mm 
Set of 5 collection bags 

 

5.  Assembly and start up 

5.1 Assembly 

If you notice transport damage while 
unpacking, notify your supplier 
immediately. Do not operate the unit! 

Dispose of the packing in an 
environmentally friendly manner. 

Base: 

Install four casters to the under side of 
the base with lock washer and nut (Fig 
1) 

Fig 1

 

Motor and fan assembly: 

Attach the motor and fan assembly (A) 
to the base, using 4 hex cap screws 
(B) and flat washers. 

Fig 2 

Attach inlet guard (A, Fig 3) to fan 
housing using 8 pan head screws (B). 

Fig 3 

Press the inlet port (C) and secure 
with provided screw. 

Attention: 

To reduce the risk of injury from 
moving parts, always keep inlet port 
covered with the caps provided, if they 
are not connected to a hose. 

 

Содержание M-708639M/T

Страница 1: ...or Staubf nger Collecteur de poussi re Original GB Operating Instructions Translations D Gebrauchsanleitung F Mode d emploi TOOL FRANCE SARL 9 Rue des Pyr n es 91090 LISSES France www jettools com M 7...

Страница 2: ...aux directives suivantes 2006 42 EC Machinery Directive Maschinenrichtlinie Directive Machines 2014 30 EU electromagnetic compatibility elektromagnetische Vertr glichkeit compatibilit lectromagn tiqu...

Страница 3: ...ly after consulting with the manufacturer Materials such as liquids metal shavings metal dust screws glass plastic or rock can cause sparks and or damage when coming into contact with any part of the...

Страница 4: ...ctor bag capacity 200L Overall DC 1100A LxWxH 940x510x2000mm Net weight 48 kg Overall DC 1100CK LxWxH 940x510x1830mm Net weight 71 kg Mains 230V 1 N PE 50Hz Output power 1 1kW 1 5HP S1 Reference curre...

Страница 5: ...the hose A Fig 7 with 2 provided clamps B Fig 7 Collector bag Fold the plastic bag over the top of the snap ring E Fig 8 Fig 8 Insert the snap ring E of the collector bag into the bottom of the housi...

Страница 6: ...of rotations so the dust falls into the collector bag ATTENTION During the changing or cleaning of the filters it s necessary to use a mask mask with filtration 7 2 Changing collector bag Always disc...

Страница 7: ...ARL beh lt sich das Recht vor jederzeit nderungen am Produkt und am Zubeh r 3 Sicherheit 3 1 Bestimmungsgem e Verwendung Dieses Absaugger t ist ausschlie lich zum Absaugen von Holzstaub geeignet Fl ss...

Страница 8: ...kabel sofort aus 3 3 Restrisiken Auch bei vorschriftsm iger Benutzung der Maschine bestehen die nachfolgend aufgef hrten Restrisiken Gef hrdung durch Staub Gef hrdung durch Strom bei nicht ordnungsgem...

Страница 9: ...chrauben C Fig 5 Kegel Einbau Montieren Sie die Kegelhalterung I Fig 6 am Geh use mit 4 Sechskantschrauben J und Muttern Montieren Sie den Kegel K von unten mit Sechskantschraube H Scheibe und Mutter...

Страница 10: ...n 7 1 Filter Reinigung Bei nachlassender Saugleistung muss der Filter gereinigt werden Zum Reinigen der Filterpatrone der DC 1100CK drehen Sie den Griff I Fig 11 einige Umdrehungen damit der anhaftend...

Страница 11: ...it et les accessoires tout moment 3 S curit 3 1 Utilisation conforme L aspirateur convient a l aspiration des poussi res de bois qui se trouve dans l air Les liquides des morceaux de m tal de verre de...

Страница 12: ...res Danger par c ble lectrique endommag us ou mal branch Risque d explosion si la machine n est pas reli e la terre 4 Sp cifications 4 1 Indications techniques Raccord 150mm 2x 100mm Volume d aspirati...

Страница 13: ...support de c ne I Fig 6 sur le b ti avec 4 vis hexagonales J et des crous Fixer le c ne K d en bas avec vis hexagonale H rondelle et crou Fig 6 Montage du tuyau Fixer le tuyau A Fig 7 avec les 2 coll...

Страница 14: ...ation faiblit nettoyer la cartouche de filtrage Pour nettoyer la cartouche DC 1100CK op rer quelques tours avec la poign e I Fig 11 afin que les poussi re accumul es tombent dans le sac Attention Port...

Отзывы: