14
Adjustments
Table Tilt
Referring to Figure 14:
1. Disconnect machine from power source.
2. Loosen
the
lock knob(s)/lock handle
(G).
3. Tilt table up to 45 degrees to the right, or up to
10 degrees to the left.
4. Tighten
the
lock knob(s)/lock handle
.
Note
: Table
stop bolt
(F, Fig. 14) must be removed
to tilt table to the left.
Adjusting 90 Degree Table Stop
Before adjusting the 90º table stop, the blade
tension must be properly adjusted (described in the
Blade Tension
section).
To adjust the 90º table stop:
1. Loosen
lock knob(s)/lock handle
(C, Fig. 15)
and tilt the table until it rests against table
stop
bolt
(B, Fig. 15); then re-tighten the
lock
knob(s)/handle
.
2. Use
a
square
(E, Fig. 16) placed on the table
and against the blade to see if the table is 90
degrees to the blade.
3. If an adjustment is necessary, loosen the
lock
knob(s)/handle
(C, Fig. 15). Tilt the table until it
is square to the blade; then re-tighten the lock
knobs.
4. Loosen
lock nut
(A, Fig. 15) and turn table
stop
bolt
(B, Fig. 15) until it contacts the table.
Tighten the
nut
(A, Fig. 15) to hold table stop in
place. When tightening the nut hold the table
stop bolt in place with a wrench to prevent
movement.
5. If necessary, adjust the
pointer
(D, Fig. 15) to
zero.
Figure 14
Figure 15
Figure 16