background image

 

1.0

  IMPORTANT SAFETY 

INSTRUCTIONS 

When using an electrical appliance, basic 
precautions should always be followed, including 
the following: 

READ ALL INSTRUCTIONS BEFORE USING THIS 
DUST COLLECTOR. 

WARNING – To reduce the risk of fire, 
electric shock, or injury: 

1.  Read and understand entire owner’s manual 

before attempting assembly or operation of this 
dust collector. 

2.  Read and understand the warnings posted on 

the machine and in this manual. 

3. Replace warning labels if they become 

obscured or removed. 

4.  This dust collector is designed and intended for 

use by properly trained and experienced 
personnel only. If you are not familiar with the 
proper and safe operation of a dust collector, do 
not use until proper training and knowledge 
have been obtained. 

5.  Do not use this dust collector for other than its 

intended use. If used for other purposes, JET 
disclaims any real or implied warranty and holds 
itself harmless from any injury that may result 
from that use. 

6.  Always wear approved safety glasses/face 

shield while using this dust collector. Everyday 
eyeglasses only have impact resistant lenses; 
they are not safety glasses. 

7.  Keep hair, loose clothing, fingers, and all parts 

of body away from openings and moving parts. 

8.  Wear hearing protection (plugs or muffs) during 

extended periods of operation. 

9.  CALIFORNIA PROPOSITION 65 WARNING:

 

This product contains chemicals known to the 
State of California to cause cancer, or birth 
defects or other reproductive harm. 

10. 

WARNING: Drilling, sawing, sanding or 
machining wood products generates wood dust 
and other substances known to the State of 
California to cause cancer. Avoid inhaling dust 
generated from wood products or use a dust 
mask or other safeguards to avoid inhaling dust 
generated from wood products.  

11. Wood products emit chemicals known to the 

State of California to cause birth defects or 
other reproductive harm. (California Health and 
Safety Code Section 25249.6) 

12.  Do not operate this machine while tired or under 

the influence of drugs, alcohol or any 
medication. 

13.  Make certain the switch is in the 

OFF

 position 

before connecting the machine to the power 
supply. Turn off all controls before unplugging. 

14.  Make certain the machine is properly grounded. 

Connect to a properly grounded outlet only. See 
Grounding instructions. 

15.  Make all machine adjustments or maintenance 

with the machine unplugged from the power 
source. 

16.  Remove adjusting keys and wrenches. Form a 

habit of checking to see that keys and adjusting 
wrenches are removed from the machine 
before turning it on.  

17.  Keep safety guards in place at all times when 

the machine is in use. If removed for 
maintenance purposes, use extreme caution 
and replace the guards immediately after 
maintenance is complete. 

18.  Check damaged parts. Before further use of the 

machine, a guard or other part that is damaged 
should be carefully checked to determine that it 
will operate properly and perform its intended 
function. Check for alignment of moving parts, 
binding of moving parts, breakage of parts, 
mounting and any other conditions that may 
affect its operation. A guard or other part that is 
damaged should be properly repaired or 
replaced. 

19. Provide for adequate space surrounding work 

area and non-glare, overhead lighting. 

20.  Keep the floor around the machine clean and 

free of scrap material, oil and grease. 

21. Keep visitors a safe distance from the work 

area. 

Keep children away.

 

22.  Make your workshop child proof with padlocks, 

master switches or by removing starter keys. 

23. Give your work undivided attention. Looking 

around, carrying on a conversation and “horse-
play” are careless acts that can result in serious 
injury. 

24.  The dust collector is intended for indoor use. To 

reduce the risk of electric shock, do not use 
outdoors or on wet surfaces. 

 

 

Содержание DC-500P

Страница 1: ...structions and Parts Manual Portable Woodworking Dust Collector Model DC 500P JET 427 New Sanford Road LaVergne Tennessee 37086 Part No M 717500 Ph 800 274 6848 Edition 1 06 2018 www jettools com Copyright 2018 JET ...

Страница 2: ...hemicals known to the State of California to cause birth defects or other reproductive harm California Health and Safety Code Section 25249 6 12 Do not operate this machine while tired or under the influence of drugs alcohol or any medication 13 Make certain the switch is in the OFF position before connecting the machine to the power supply Turn off all controls before unplugging 14 Make certain t...

Страница 3: ...sed air to remove chips or debris do not use bare hands 39 Do not leave the machine when it is plugged in Unplug from outlet when not in use and before servicing 40 Do not stand on the machine Serious injury could occur if the machine tips over 41 The dust collector is intended for household non industrial use Familiarize yourself with the following safety notices used in this manual This means th...

Страница 4: ...8 0 User maintenance 10 8 1 Additional servicing 10 9 0 Troubleshooting DC 500P Dust Collector 11 10 0 Replacement Parts 12 10 1 1 DC 500P Portable Dust Collector Exploded View 12 10 1 2 DC 500P Portable Dust Collector Parts List 13 11 0 Electrical Connections for DC 500P 14 11 1 Electrical Connections for 3 4HP 1PH 115V only 14 11 2 Electrical Connections for 3 4HP 1PH 230V only 14 12 0 Warranty ...

Страница 5: ...WC 5 8 inH2O 147 3 mmH2O Impeller Type radial fin Diameter 9 in 228 6 mm Fin thickness 14 ga 2mm Material steel Collection bag Bag material cloth 5 micron Bag size Dia x L when inflated 16 x 24 in Bag capacity 4 7 cu ft 0 13 CBM Main materials Base sheet metal Body housing sheet metal Dust funnel plastic Dust hose PVC Paint finish powder coat Dimensions Approx overall dimensions assembled LxWxH 24...

Страница 6: ...xible hose B 1 Collection bag C 2 4 Dia Wire clamps D 1 5 Dia wire clamp E 1 Dust funnel F 4 Casters with fasteners G 1 Wall mount plate H 1 Upper support tube I 1 Funnel support bracket J 1 Locking lever K 1 Inlet cap L 1 Lower support tube M 1 Inlet adaptor N Fasteners see Figure 5 2 2 Carriage bolts M8x20 HP1 2 Lock washers 8mm HP2 3 Flat washers 8mm HP3 2 Hex nuts M8 HP4 2 Butterfly clamps HP5...

Страница 7: ...ed mount funnel bracket J to upper support tube I with locking lever K and washer HP3 Install funnel F with carriage bolts washers and nuts HP1 2 3 4 Figure 5 4 5 Push inlet adaptor N Figure 5 5 onto inlet port until the holes align and secure with the provided self tapping screws 6 Press ring of inlet cap L onto adaptor Press cap over inlet when inlet is not being used Figure 5 5 7 Place a 4 inch...

Страница 8: ...levant codes This machine must be properly grounded to help prevent electrical shock and possible fatal injury The DC 500P Dust Collector is rated at 115 230V power and is pre wired for 115 volt The unit comes with a plug designed for use on a circuit with a grounded outlet that looks like the one pictured in A Figure 6 1 Before connecting to power source be sure switch is in off position It is re...

Страница 9: ...available or should be used with this tool If the tool must be reconnected for use on a different type of electric circuit the reconnection should be made by qualified service personnel and after reconnection the tool should comply with all local codes and ordinances 6 2 Voltage conversion To convert the dust collector to 230 volt power remove motor junction box cover and change the incoming power...

Страница 10: ...ts or maintenance Failure to comply may result in serious injury No lubrication is required for the dust collector All bearings are pre lubricated and sealed and require no further attention Empty collection bag when full The cloth dust collection bag is washable Make frequent inspections of motor fan and blow out with low pressure air hose or vacuum any accumulation of foreign material to maintai...

Страница 11: ...aker at power source Motor overheats Motor overloaded Reduce load on motor Air circulation through motor is restricted Clean motor fan with compressed air to restore normal air circulation Faulty capacitor Replace run capacitor Motor stalls resulting in blown fuses or tripped circuit Motor overloaded Reduce load on motor Impeller blocked with debris Empty bag clean out hoses and housing Short circ...

Страница 12: ...del Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately Non proprietary parts such as fasteners can be found at local hardware stores or may be ordered from JET Some parts are shown for reference only and may not be available individually 10 1 1 DC 500P Portable Dust Collector Exploded View ...

Страница 13: ...00P 019 Strain Relief 1 20 DC500P 020 Power Cord with Plug 16AWGx3C 7 1 2ft 1 21 TS 1490031 Hex Head Bolt M8x20 17 22 DC500P 022 Impeller 1 23 DC500P 023 Cover Assembly 1 24 DC500P 024 Philips Pan Hd Self Tapping Screw ST4 2x12 7 mm 10 25 DC500P 025 Inlet Cap 1 26 DC500P 026 Wire Clamp Ø4 2 27 DC500P 027 Flexible Hose Ø4 x 10 1 28 DC500P 028 Lower Support Tube 1 29 DC500P 029 Butterfly Clamp 2 30 ...

Страница 14: ...14 11 0 Electrical Connections for DC 500P 11 1 Electrical Connections for 3 4HP 1PH 115V only 11 2 Electrical Connections for 3 4HP 1PH 230V only ...

Страница 15: ...itional action needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JET website More Information JET is constantly adding new products For complete up to date product information check with your local distributor or visit the JET website How State Law App...

Страница 16: ...16 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com ...

Отзывы: