Mains
3~400V, PE, 50Hz
Output power
1,5kW (2HP) S1
Reference current
2.8 A
Extension cord (H07RN‐F)
4x1,5 mm²
Installation fuse protection
16 A
Protection class
I
Overall (LxWxH)
1000x750x2000 mm
Net weight
40 kg
4.2 Noise emission
Measured, in 1m distance, 1.6m above the floor, with flexible
hose connected. (inspection tolerance 4 dB).
Acoustic pressure level
(EN ISO 11202):
LpA 80 dB(A).
The specified values are emission levels and are not
necessarily to be seen as safe operating levels.
As workplace conditions vary, this information is intended to
allow the user to make a better estimation of the hazards and
risks involved only.
4.3 Content of delivery
Filter bag
Collection bag
Mobile casters (4x)
Dust inlet 2 x 100 mm
Hose clamps 100mm (2x)
Hose ground wire
Operating manual
Spare parts list
4.4 Unit description
Fig 1
Fig 2
A….Hose
B….Collector Body & Fan/Motor Assembly
C….Housing
D….Base
E….Filter Bag Hanger
F….Support Rods (3x)
G….Inlet
H….Filter Bag
I…..Gasket
J….Mobile Casters (4x)
K….Hex. Bolts (M8x16, 18pc; M8x25, 4pc; M6x20, 6pc)
Hex. Nuts (M8, 4pc; M6, 6pc)
Head Screws (M6x10, 16pc)
Washer (M8, 26pc; M6, 28pc)
Hex. Wrench (5mm, 1pc)
L….Motor Base
M…Handle
N….Retainer Strap (2x)
O….Hose
P…..Hose Clamp (2x)
Q….Collector Bag
R…..Switch
S……Motor
T……CEE Plug (400V) or Wire Plug (230V)
W….Outlet connector
5. Assembly and start up
5.1 Installation
The machine is designed to operate in dry, enclosed rooms
and must be placed stable on firm and levelled ground.
The room temperature must be b5°C and +40°C.