background image

 

 

 

20.  Make your workshop child proof with padlocks, master switches or by removing starter keys. 

21. Give your work undivided attention. Looking around, carrying on a conversation and “horse-play” are 

careless acts that can result in serious injury. 

22. Do not use the dust collector for anything except wood dust. Materials such as liquids, metal shavings, 

metal dust, screws, glass, plastic or rock can cause sparks and/or damage when coming into contact with 
any part of the dust collector. 

23.  Use recommended accessories; improper accessories may be hazardous. 

24.  Maintain tools with care. Follow instructions for lubricating and changing accessories. 

25. Turn off the machine before cleaning. Use a brush or compressed air to remove chips or debris — do not 

use your hands. 

26.  Do not stand on the machine. Serious injury could occur if the machine tips over. 

27. Never leave the machine running unattended. Turn the power off and do not leave the machine until it 

comes to a complete stop. 

28.  Remove loose items and unnecessary work pieces from the area before starting the machine. 

29.  Never place hands near the inlet of the machine. 

30.  Always make certain machine is off and unplugged when making any connections to the inlet. 

 

Familiarize yourself with the following safety notices used in this manual: 

 This means that if precautions are not heeded, it may result in minor injury and/or possible 

machine damage. 
 

 This means that if precautions are not heeded, it may result in serious injury or possibly even 

death. 
 
 

- - SAVE THESE INSTRUCTIONS - - 

 

 

 
 

 

 

Introduction 

This manual is provided by Walter Meier (Manufacturing) Inc., covering the safe operation and maintenance 
procedures for model DC-1100VX Series Dust Collectors. This manual contains instructions on installation, 
safety precautions, general operating procedures, maintenance instructions and parts breakdown. This 
machine has been designed and constructed to provide years of trouble free operation if used in accordance 
with instructions set forth in this manual. If there are any questions or comments, please contact either your 
local supplier or Walter Meier. Walter Meier can also be reached at our website: www.waltermeier.com. 

 

Содержание DC-1100VX Series

Страница 1: ...ectors DC 1100VX with Bag Filter Kit DC 1100VX with Canister Kit WALTER MEIER Manufacturing Inc 427 New Sanford Road LaVergne Tennessee 37086 Part No M 708657 Ph 800 274 6848 Revision A 03 2011 www waltermeier com Copyright 2011 Walter Meier Manufacturing Inc Now with ...

Страница 2: ...age prepaid to a location designated by us For the name of the location nearest you please call 1 800 274 6848 You must provide proof of initial purchase date and an explanation of the complaint must accompany the merchandise If our inspection discloses a defect we will repair or replace the product or refund the purchase price at our option We will return the repaired product or replacement at ou...

Страница 3: ...l Models 13 Remote Control Optional Accessory 13 Dust Collector RF Remote Power Control Optional 13 Turning the DC RC On Off 13 Changing Operating Frequency 14 Installing the DC RC Remote Power Control Optional Accessory 14 Maintenance 15 Cleaning the Filter Bag DC 1100VX BK and DC 1100VX 5M 15 Removing the Collector Bag DC 1100VX BK 15 Cleaning the Filter DC 1100VX CK 15 Removing the Collector Ba...

Страница 4: ...rystalline silica from bricks cement and other masonry products Arsenic and chromium from chemically treated lumber Your risk of exposure varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as face or dust masks that are specifically designed to filter out microscopic particles...

Страница 5: ...emove loose items and unnecessary work pieces from the area before starting the machine 29 Never place hands near the inlet of the machine 30 Always make certain machine is off and unplugged when making any connections to the inlet Familiarize yourself with the following safety notices used in this manual This means that if precautions are not heeded it may result in minor injury and or possible m...

Страница 6: ...gth in 29 5 Micron Filter Bag Kit Stock Number 708636MF Filter Bag Efficiency 98 of 5 micron particles 92 of 3 micron 74 of 1 micron Filter Bag Length installed in 32 Filter and Collector Bag Diameter in 20 Collector Bag Capacity cu ft 5 3 Collector Bag Length installed in 29 Canister Filter Kit Stock Number 708639B Canister Length in 25 Canister Efficiency 86 of 1 micron particles 98 of 2 micron ...

Страница 7: ...00VX BK x x DC 1100VX CK x x DC 1100VX 5M x x Table DC 1100VX Dust Collector cartons Hardware Bag for Base Unit SN DC1100 HP 16 M8 x 16 Hex Cap Screws K 22 M8 Flat Washers L 08 M6 x 12 Pan Head Flange Screws M 06 M8 Hex Nuts N Base Unit Hardware Hardware Bag for Cone Assembly SN DC1100 HP2 1 M8 x 16 Hex Cap Screw O 1 M8 Flat Washer P 1 M8 Hex Nut R 4 M6 x 12 Hex Cap Screws S 4 M6 Hex Nuts T Cone A...

Страница 8: ... U 4 Knobs V Canister Filter Kit Contents Canister Filter Hardware SN DC1100 CHP Canister Filter Hardware 30 Micron Bag Filter Kit SN 708636F 1 Upper Bag Hanger Y 1 Hanger Bracket Z 1 Collector Bag X 1 Filter Bag W 1 Retainer Strap AA Filter Bag Kit Contents 5 Micron Bag Filter Kit SN 708636MF 1 Upper Bag Hanger BB 1 Hanger Bracket CC 1 Filter Bag DD 5 Collector Bags EE 1 Retainer Strap FF 1 Snap ...

Страница 9: ...ach M8 x 16 hex cap screws and M8 flat washers B Tighten with a 13mm wrench The dust collector must not be connected to the power source during assembly Failure to comply may result in serious injury Referring to Figure 3 4 Attach impeller cover A to impeller housing D using eight M6 x 12 pan head screws B Press the inlet ports C onto the inlet guard until it snaps into place To reduce the risk of...

Страница 10: ...one support bracket E to the housing with four M6x12 hex cap screws F and tighten from beneath with four M6 hex nuts G 9 Install the cone H from beneath using the M8x16 hex cap screw J M8 flat washer K and M8 hex nut L and tighten Hose Referring to Figure 7 10 Attach the hose B between the collector housing A and the impeller housing D with two clamps C Tighten the clamps to secure the hose This c...

Страница 11: ... F Collector Bag Installation 30 Micron Kit Referring to Figure 9 4 Insert the ring of the collector bag A at an angle into the housing B through the opening at the bottom Pull down on the bag to make sure it seats in the housing 5 Position the plastic window in front so that you can easily see when the collector bag is full Collector Bag Installation 5 Micron Kit The 5 Micron Filter Bag Kit inclu...

Страница 12: ...using A Fig 5 and tighten the knobs on the canister filter Figure 10 Collector Bag 3 Place the snap ring over the top of the plastic bag and fold the bag over the ring approximately three inches as shown in Figure 11 4 Insert the snap ring A Figure 12 of the collector bag into the bottom of the housing at an angle 5 Pull down on the snap ring to make sure it seats in the housing Note Make sure the...

Страница 13: ...used for activating Dust Collection units powered by 115V only up to 1 1 2HP If your dust collector is currently set up for 230V operation or you choose to convert it to 230V at a later time you must purchase the DC RC230 Remote Power Control unit SN 708636D Figure 13A Figure 13B Dust Collector RF Remote Power Control Optional The DC RC Remote Power Control Figure 14 should be used for activating ...

Страница 14: ... device as described in Turning the DC RC On Off and verify that other devices using the same type remote control do not turn on Figure 15 Installing the DC RC Remote Power Control Optional Accessory The DC RC Remote Power Control unit can be placed anywhere for convenience and portability if used to control other machines or it can be mounted as a permanent part of a machine such as the DC 1100VX...

Страница 15: ...n maximum performance with JET dust hoods hoses clamps fittings and blast gates Cleaning the Filter DC 1100VX CK Never perform maintenance on this machine before turning switch off and removing plug from power source Failure to comply may cause serious injury Clean both the canister filter and collector bags frequently to keep the collector s performance at its optimum To clean the filter turn the...

Страница 16: ...16 Parts Parts Breakdown DC 1100VX Dust Collectors ...

Страница 17: ... Motor Packing 1 10 AB411040 Impeller 11 1 11 411036W Inlet Guard 1 12 427028 Inlet Port 2 4 1 13 420203 Inlet Cap 1 14 430034 Inlet Flange Packing 1 15 411041W Base 1 16 402036 Pivoting Caster 4 17 420012W Housing 20 1 18 402004W Support 3 20 411009 Hose 1 21 420010 Ring Clamp 5 2 31 ST050204 Tapping Screw M5x10 6 32 KS050525 Key 5x5x25 mm 1 34 TS 1540061 Hex Nut M8 10 35 TS 0561031 Hex Nut 3 8 1...

Страница 18: ...ty DC1200 53 Grounding Label not shown 1 DC1200 54 Direction Label not shown 1 DC1100VX ID I D Label not shown 1 DC1100 HP Hardware Package for Base Unit 1 DC1100 HP2 Hardware Package for Cone Assembly 1 DC1100 WL Warning Label not shown 1 ...

Страница 19: ... 1 8 331051 Soft Grip Handle 2 9 TS 1540041 Hex Nut M6 8 10 708739 Filter 1 11 331052 Shaft 1 12 TS 1482041 Hex Cap Screw M6X20 4 13 TS 2361061 Lock Washer M6 4 14 TS 1550041 Flat Washer M6 4 15 331012 Scraper 2 16 331017 Strip 2 17 331015 Press Plate 2 18 TS 1482021 Hex Cap Screw M6x12 4 19 331037 Knob 4 20 331031 Pad 1 21 331009 Support 1 22 ST049200 Tapping Screw M4X8 4 23 331038 Snap Ring 1 24...

Страница 20: ...8636F Index No Part No Description Size Qty 708636F 30 Micron Filter and Collection Bag Kit index 1 5 1 708698 Filter Bag 30 Micron 1 2 AB410012 Retainer Strap 1 3 708699A Collector Bag 1 4 430038 Hanger 1 5 523011W Hanger Bracket 1 ...

Страница 21: ...art No Description Size Qty 708636MF 5 Micron Filter and Collection Bag Kit index 1 6 1 708706 Filter Bag 5 Micron 1 2 AB410012 Retainer Strap 1 3 331038 Snap Ring 1 4 709563 Plastic Bag Package of 5 1 5 430038 Hanger 1 6 523011W Hanger Bracket 1 ...

Страница 22: ...22 Wiring Diagram DC 1100VX Dust Collectors ...

Страница 23: ...23 ...

Страница 24: ...24 WALTER MEIER Manufacturing Inc 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www waltermeier com ...