Donaldson Torit Unimaster UMA 100 Скачать руководство пользователя страница 1

This manual contains specific precautions related to worker safety. The hazard alert image denotes 
safety related instructions and warnings in this manual. DO NOT operate or perform maintenance on this 
collector until you have read and understood the instruction and warnings contained within this manual.

Unimaster

®

 Dust Collector 

UMA 40, 70, 100, 150 and 250 Built After August 2005

UMA 450 and 750 Built After March 2006

Installation and Operation Manual

Installation, Operation, and Service Information

IOM AD3547701 (ENG)

Revision 4

English

Master Language

UMA 250

Bin Vent Base

(H Type)

UMA 250

Bin Base

UMA 250

55-Gallon Drum Base

Содержание Unimaster UMA 100

Страница 1: ...til you have read and understood the instruction and warnings contained within this manual Unimaster Dust Collector UMA 40 70 100 150 and 250 Built After August 2005 UMA 450 and 750 Built After March...

Страница 2: ...ment This manual has been supplied to assist with the installation operation and maintenance for the collector purchased Please read the manual before installing operating or performing maintenance on...

Страница 3: ...ector Location 5 Hoisting Information 5 Standard Equipment 5 Hopper and Leg Installation 5 Provisional Anchor Bolt Recommendations 6 Collector Installation 6 Electrical Wiring 8 Inlet Assembly 8 Preli...

Страница 4: ...r control Donaldson does not provide engineering consulting services related to process or dust hazard analyses or code and standard compliance Complying with applicable codes and standards and managi...

Страница 5: ...ontroller to control the filter cleaning operation Other options include explosion relief vents static grounding weather hoods and caster frames Purpose and Intended Use Misuse or modification of this...

Страница 6: ...collector which means that cleaning starts when the fan is turned OFF and the appropriate fan run down time is complete The solid state timer automatically starts the cleaning sequence 75 seconds aft...

Страница 7: ...Failure to remove shipping materials from the collector will compromise collector performance Inspect collector to ensure all hardware is properly installed and tight prior to operating collector Ins...

Страница 8: ...must be adequately supported to prevent severe personal injury and or property damage When hazardous conditions or materials are present consult with local authorities for the proper location of the c...

Страница 9: ...70 Bin Collector Installation UMA 40 to 70 Hopper and 55 Gallon Drum Base Styles 1 Prepare the foundation or support framing in the selected location Locate and install anchors 2 Lift collector into p...

Страница 10: ...ng customer supplied hardware Typical Installation UMA 100 to 750 or Two Piece Shipment 5 Remove the lifting brackets from the top of the base assembly 6 Apply two strips of sealant or caulk to the ho...

Страница 11: ...order Side inlets are not interchangeable with back inlets Contact Donaldson if additional changes are necessary 1 Remove the inlet blank from the specified location 2 Replace damaged sealant if neces...

Страница 12: ...nd the shaker motor runs for approximately 30 seconds Typical Wiring Diagram Three Phase Power Supply Shaker motor contactor is de energized and the timer resumes inactive status Note Before a cleanin...

Страница 13: ...Unimaster Dust Collector UMA 40 through 750 10 230 Volt Single Phase Power Supply Wiring Diagram...

Страница 14: ...11 Donaldson Company Inc 115 Volt Single Phase Power Supply Wiring Diagram...

Страница 15: ...trols and solenoid enclosures if applicable are properly wired and all service switches are in the OFF position 7 Check that all optional accessories are installed properly and secured 8 Turn power ON...

Страница 16: ...procedures Note the standard collector is not equipped with access platforms unless noted on the specification drawings Electrical service or maintenance work must be performed by a qualified electri...

Страница 17: ...besheet seal 5 Insert bag pockets into the shaker bar slots 6 Push the filter assembly the remaining distance into the collector and check that all pockets are firmly seated in the shaker bar 7 Lift r...

Страница 18: ...pressure ports on the side of the gauges 3 Attach the mounting bracket using three 6 32 x 1 4 in screws supplied 4 Mount the gauge and bracket assembly to the supporting structure using two self drill...

Страница 19: ...nels Static Bonding for Filters Optional media bonding and grounding components are available for UMA collectors equipped with antistatic filter bags 1 If the collector is ordered with antistatic filt...

Страница 20: ...t outside buildings and away from normally occupied areas Explosion vents should be inspected regularly to confirm physical and operational condition Replace any damaged parts immediately Standard exp...

Страница 21: ...the dust container is not full Turn fan OFF and allow the controller to perform several complete cleaning cycles Replace filter bags Motor speed low Check all supply voltage phase and motor connection...

Страница 22: ...____________ Collected Dust _________________________________________________________________________ Dust Properties Kst_______________Pmax______________MIE____________MEC_________________ Accessorie...

Страница 23: ...h of the foregoing warranty on services Products manufactured by a third party Third Party Product may constitute contain be contained in incorporated into attached to or packaged together with the go...

Страница 24: ...ant Notice Many factors beyond the control of Donaldson can affect the use and performance of Donaldson products in a particular application including the conditions under which the product is used Si...

Отзывы: