Problem

Probable Cause

Solution

Excess Wire Tension On Union

• 

Excess wire between cord grip 
and UV lamp connector

• 

Loosen cord grip and adjust length of 
wire to match Lamp Insert handle

Control Panel Not Seating

• 

Excess wire not stored in UV 
housing

• 

Lamp Insert handle too long

•  Reposition wire in UV housing
• 

Trim and reconnect Lamp Insert 
handle

Lamp Insert Not Seating

• 

Check alignment of keyway 
and top plate

• 

Check for debris in UV housing

•  Re-position top plate
• 

Flush debris from UV housing with 
hose

Water in Enclosure

• 

Enclosure cover not secure

• 

Conduit hub not secure

•  Align and tighten enclosure cover
• 

Tighten conduit hub

“Lamp Active” Light Not Lit

• 

No power from main breaker 
panel

• 

No power to UV Lamp

•  The “Lamp Active” bulb has 

burned out

• 

Check wiring and main breaker panel

• 

Check internal wiring to UV Lamp

• 

Check internal wiring to UV Lamp

•  Check orientation of control panel 

cover

UV Lamp Not Lit

•  Inbound power inactive
• 

UV Lamp burned out

• 

Check wiring to UV Lamp

• 

Check UV Lamp

Auxiliary Alarm After Start Up

•  Alarm settings incorrect
•  Alarm condition is active

•  Check alarm setting jumpers for 

proper NO/NC

• 

Check external devices

Troubleshooting Guide for Jet Model 952 UV Disinfection Device

Содержание 952

Страница 1: ...g components should be supplied by the installer 1 All Purpose Cement 2 Clear Cleaner for plastics 3 Drill with Universal Bit 4 Clean soft cloth 5 Isopropyl alcohol 6 Small slotted screwdriver 7 Wire...

Страница 2: ...not flow through the device correctly and the UV disinfection will not be effective See Figure 1 2 Clean the ends of the upstream and downstream piping and the hubs of the UV cross with clear plastic...

Страница 3: ...of the 1 PVC pipe See figure 3 The opposite end will already be glued to the bushing on the control panel UV lamp wire 4 Glue the other end of the 1 PVC pipe into the coupler that is on the UV insert...

Страница 4: ...remaining lead to the common C terminal WIRE THE CONTROL PANEL 1 The UV unit operates on 120 VAC single phase power A 15 amp circuit breaker on the main electrical panel should be used for the UV dis...

Страница 5: ...the disinfection chamber and riser until even with the final grade being no more than 6 below the bottom of the control panel 11 Turn the UV disinfection device on at the main electrical panel 12 The...

Страница 6: ...hose Water in Enclosure Enclosure cover not secure Conduit hub not secure Align and tighten enclosure cover Tighten conduit hub Lamp Active Light Not Lit No power from main breaker panel No power to U...

Страница 7: ...ure to follow the suggestions outlined in any associated product documentation or Owners Manuals Items normally consumed in service such as fuses filter cartridges spin plates grease oil etc are not w...

Отзывы: