background image

 9 

It is recommended that the buffer be connected to a 
minimum 15-amp circuit with circuit breaker or fuse. 
If using fuses, they should be time-delay fuses 
marked “D”. 

Local codes take precedence over 

recommen-dations. 

6.1

  GROUNDING INSTRUCTIONS 

1. All Grounded, Cord-connected Tools: 

This tool must be grounded. In the event of a 
malfunction or breakdown, grounding provides a 
path of least resistance for electric current to reduce 
the risk of electric shock. This tool is equipped with 
an electric cord having an equipment-grounding 
conductor and a grounding plug. The plug must be 
plugged into a matching outlet that is properly 
installed and grounded in accordance with all local 
codes and ordinances. 

Do not modify the plug provided - if it will not fit the 
outlet, have the proper outlet installed by a qualified 
electrician. 

Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. The 
conductor with insulation having an outer surface 
that is green with or without yellow stripes is the 
equipment-grounding conductor. If repair or 
replacement of the electric cord or plug is 
necessary, do not connect the equipment-grounding 
conductor to a live terminal. 

 

Check with a qualified 

electrician or service pe

r

sonnel if the grounding 

instructions are not completely understood, or if 
in doubt as to whether the tool is properly 
grounded. Failure to comply may cause serious 
or fatal injury.

 

Use only 3-wire extension cords that have 3-prong 
grounding plugs and 3-pole receptacles that accept 
the tool's plug. 

Repair or replace damaged or worn cord 
immediately. 

2. Grounded, cord-connected tools intended for use 
on a supply circuit having a nominal rating 

less than 

150

 volts: 

This tool is intended for use on a circuit that has an 
outlet that looks like the one illustrated in 

A, 

Figure 

6-1. An adapter, shown in 

B

 and 

C

, may be used to 

connect this plug to a 2-pole receptacle as shown in 

B

 if a properly grounded outlet is not available. The 

temporary adapter should be used only until a 
properly grounded outlet can be installed by a 
qualified electrician. 

This adapter is not permitted in 

Canada.

 The green-colored rigid ear, lug, and the 

like, extending from the adapter must be connected 
to a permanent ground such as a properly grounded 
outlet box. 

3. Grounded, cord-connected tools intended for use 
on a supply circuit having a nominal rating between 

150 - 250 volts

, inclusive: 

This tool is intended for use on a circuit that has an 
outlet that looks like the one illustrated in 

D,

 Figure 

6-1. A grounding plug may be installed, that looks 
like the plug illustrated in 

D

; or the grinder may be  

“hard-wired” to a panel, provided there is a 
disconnect for the operator.  

Make sure the tool is connected to an outlet having 
the same configuration as the plug. No adapter is 
available or should be used with this tool. If the tool 
must be reconnected for use on a different type of 
electric circuit, the reconnection should be made by 
qualified service personnel; and after reconnection, 
the tool should comply with all local codes and 
ordinances. 

6.2

  Extension cords 

The use of extension cords is discouraged. Try to 
position equipment near the power source. If an 
extension cord becomes necessary, use only three-
wire extension cords that have three-prong 
grounding type plugs and three-prong receptacles 
that accept the tool's plug. Replace or repair 
damaged or worn cord immediately. 

Make sure your extension cord is good condition, 
and is heavy enough to carry the current your 
product will draw. An undersized cord will cause a 
drop in line voltage resulting in loss of power and 
overheating.  

Table 2 shows the correct size to use depending on 
cord length and nameplate ampere rating. If in doubt, 
use the next heavier gage. The smaller the gage 
number (AWG), the heavier the cord. 

Amp rating 

Volts 

Total length of cord in feet 

More 
Than 

Not 

More 
Than 

120 
240 

25 
50 

50 
100 

100 
200 

150 
300 

 AWG 

0 6   18 

16 

16 

14 

6 10   18 

16 

14 

12 

10 12   16 

16 

14 

12 

12 16   14 

12 

Not 
Recommended 

Extension Cord Recommendations 

Table 2 

6.3

  Voltage conversion 

To change voltage input to 230-volt on the IBG-
8SSB or IBG-10SSB: 

1.  Disconnect buffer from power source. 

2.  Turn buffer over and remove the base plate. 

3.  Rewire the leads according to the appropriate 

diagram in 

sect. 12.0. 

Reinstall base plate. 

4.  Remove the existing plug from the power cord 

and attach a UL/CSA listed plug designed for 
230V power. 

Содержание 577408

Страница 1: ...48 www powermatic com Part No M 577408 Edition 1 12 2019 Copyright 2019 Powermatic Operating Instructions and Parts Manual Industrial Buffing Machines Models IBG 8SSB IBG 10SSB IBG 12SSB IBG 8SSB incl...

Страница 2: ...ing to see that keys and adjusting wrenches are removed from the machine before turning it on 16 Keep safety guards in place at all times when the machine is in use If removed for maintenance purposes...

Страница 3: ...this manual This means that if precautions are not heeded it may result in minor injury and or possible machine damage This means that if precautions are not heeded it may result in serious or possibl...

Страница 4: ...10 7 2 General procedure 10 8 0 User maintenance 10 8 1 Changing Wheels 10 8 2 Wheel balancing 11 8 3 Buffer maintenance 11 8 4 Additional servicing 11 9 0 Troubleshooting IBG SSB series Buffers 12 10...

Страница 5: ...used in accordance with the instructions set forth in this document If there are questions or comments please contact your local supplier or JET JET can also be reached at our web site www jettools co...

Страница 6: ...5 8 in 203 2 x 12 7 x 16 mm not provided Wheel material Woven cotton spiral sewn and half spiral sewn not provided Wheel flange diameter 3 3 8 in 85 mm 4 1 8 in 104 8 mm Spacers length 1 2 5 8 1 in 1...

Страница 7: ...a better estimation of the hazards and risks involved only L length W width H height D depth n a not applicable The specifications in this manual were current at time of publication but because of ou...

Страница 8: ...plate contains ventilation slots for heat dissipation These slots should not be obstructed The rubber feet should be left on the machine when mounting as they allow air circulation as well as vibrati...

Страница 9: ...ter is not permitted in Canada The green colored rigid ear lug and the like extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box 3 Grounded cord co...

Страница 10: ...w moments to completely stop Note After extended operation the machine housing may be warm to the touch This is not abnormal Figure 7 1 safety key IBG 8SSB 10SSB only 7 2 General procedure 1 Turn on b...

Страница 11: ...e outer flange a little Snug the nut and spin the wheel by hand to check 2 If wobble still exists continue repeating step 1 rotating outer flange incrementally in the same direction Make sure to keep...

Страница 12: ...ug Inspect cord or plug for damaged insulation and shorted wires Short circuit in motor or loose connections Inspect all connections on motor for loose or shorted terminals or worn insulation Motor fa...

Страница 13: ...s are listed on the following pages To order parts or reach our service department call 1 800 274 6848 Monday through Friday 8 00 a m to 5 00 p m CST Having the Model Number and Serial Number of your...

Страница 14: ...14 11 1 1 IBG 8SSB Buffer Exploded View...

Страница 15: ...G8 17 Motor Fan 1 19 BB 6204ZZ Ball Bearing 6204ZZ 2 20 IBG8 19 End Bell 2 21 TS 1540031 Hex Nut M5 4 22 IBG8VSB 22 End Cap 2 23 IBG8VSB 23 Spacer L 25mm 2 24 IBG8VSB 24 Spacer L 16mm 2 25 IBG8VSB 25...

Страница 16: ...16 11 2 1 IBG 10SSB Buffer Exploded View...

Страница 17: ...BG10 17 Motor Fan 1 18 BB 6206ZZ Ball Bearing 6206ZZ 2 19 IBG10 19B End Bell 2 20 IBG8 26 Truss Head Screw 1 4 20 x 3 4 8 21 IBG10SSB 21 End Cap 2 22 TS 0255011 Socket HD Button Screw 5 16 x 3 8 6 23...

Страница 18: ...18 11 3 1 IBG 12SSB Buffer Exploded View...

Страница 19: ...2 20 IBG8 26 Truss Head Screw 1 4 20 x 3 4 8 21 IBG10SSB 21 End Cap 2 22 TS 0255011 Socket HD Button Screw 5 16 x 3 8 6 23 IBG12SSB 23 Spacer Kit includes 23 1 thru 23 4 1 23 1 IBG12SSB 23 1 Spacer L...

Страница 20: ...20 12 0 Electrical Connections 12 1 Wiring diagram for IBG 8SSB...

Страница 21: ...21 12 2 Wiring diagram for IBG 10SSB...

Страница 22: ...22 12 3 Wiring diagram for IBG 12SSB...

Страница 23: ...tional action needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Loc...

Страница 24: ...24 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com...

Отзывы: