PN 115.04.7706 - INSTRUCTION MANUAL OF GPU JET-POWER DIESEL 90kVA - 115VAC, 400Hz / 28VDC, 2500A - PN 115.09.7701.
GPU JET-POWER DIESEL 90kVA – 115VAC, 400Hz / 28VDC, 2500A – PN 115.09.7090 22/40
6.1.8 –
EDG5500 –ELECTRONIC DIGITAL GOVERNOR (
GPU ALL ENGINE 2014/2015
):
DIGITAL REGULATOR ASSEMBLY SPEED:
The EDG5500 speed regulator is robust enough to be placed in an electrical panel. To prevent
the speed governor has contact with water mist or condensation, the controller is mounted
vertically, this allows the fluid to drain. Extreme heat should be avoided.
ADJUSTMENT OF THE SPEED SENSOR (PICK-UP)
With the engine, adjust the space between the speed sensor and the number of teeth of the
rack. The space shall be not less than 0,020pol (0.45mm). Normally, you will achieve a
satisfactory air gap retreating the speed sensor in 3/4 turn after touching the teeth of the rack.
Tension speed sensor must be at least 1V RMS AC during the match.
A USER INTERFACE:
THE DISPLAY AND BUTTONS
The EDG5500 have a user interface. All settings are made using the LCD and five buttons -
COLUMN three buttons, an arrow UP button, DOWN ARROW button. See CHART 1.
LOCKING AND UNLOCKING EDG DISPLAY.
To unlock and enable the display, press and hold simultaneously for 2 seconds the UP
ARROW and DOWN ARROW buttons. The LOCKED indicator will be off. The display
block is performed by performing the same operation. If LOCKED parameter is ON, the
display will lock after 5 minutes without use.
QUIKSET MENUS, AND ADVANCED SPECIAL
The EDG5500 has three configuration menus: Quikset, Special and Advanced. We changed
only the Quickset menu. All parameter settings are made using the LCD and five buttons -
COLUMN three buttons, an arrow UP button, DOWN ARROW button. See CHART 1.
MENU QUIKSET
This menu is designed to be the most frequently used parameters. It is used the method
patented Quikset to select and modify these parameters.
VIEW / CHANGE PARAMETERS QUIKSET:
All "Quikset parameters" are displayed on the LCD in five rows of three parameters on each
line. The active line is indicated by the parameters in the line being displayed. To select the
next line, press any button COLUMN, cyclic and continuous, and will cover all lines.