![Jet Cleen JC-UHE130B Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/jet-cleen/jc-uhe130b/jc-uhe130b_installation-operation-and-maintenance-manual_3769157008.webp)
7
ATTENTION
Qualified tec
h
nicians install
ing
the
machine are obliged to train the operators
about
the
machine utilization and
safety procedures to be followed. They
must provide a real “demonstration” and
verify that machine
's
instructions are
available to the operators.
Following warnings should be noted:
The
dishwasher
must
be
installed
in accordance with local codes, or in
the absence of
local
codes,
installed
in
accordance
with
the
applicable
requirements in the National Electrical
Code, NFPA 70, Canadian Electrical Code
(CEC), Part 1, CSA C22.1, and Standard for
Ventilation Control and Fire Protection of
Commercial Cooking Operations, NFPA 96.
WARNING!
DO NOT OPEN THE DOOR QUICKLY IF
CYCLE HAS NOT ENDED.
DO NOT DIP BARE HANDS IN
TO
THE
WASHING SOLUTION.
DO NOT
REMOVE
THE PANELS IF
THE
MACHINE
HAS
NOT
BEEN DISCONNECTED
FROM THE POWER AND WATER SUPPLY.
DO NOT BYPASS THE MACHINE
'S
PROTECTION
DEVICES
(MICROSWITCHES,
PANELS,
ETC
) PROVIDED BY THE
MACHINE
MANUFACTURER IF NOT IN THE
PRESENCE OF TRAINED TECHNICIAN THAT
CAN TAKE
THE
PROPER PRECAUTIONS.
DO NOT UTILISE THE MACHINE TO WASH
OBJECT
S
OF SHAPE, TYPE, SIZE, AND
MATERIAL NOT COMPATIBLE WITH THE
MACHINE.
DO NOT OPERATE THE MACHINE IF NOT
PROPERLY CONNECTED, ACCORDING TO
THE SPECIFICATIONS AND REQUIREMENTS
OF THE LOCAL LAW AND PRESCRIPTION OF
MANUFACTURER, MAKING SURE THAT ALL
SAFETY DEVICES ARE OPERATIVE.
ID/RATING/DATA PLATE
ID/Rating plate of the appliance contains
identification and technical data and is
located on front panel.
2A – WATER CONNECTION
N.B.
The s
hut-off valve must be a single
direction, spool, sphere, lid control type,
which can shut
off the
water supply
quickly and totally. The water pressure
and flow must conform to the data
diagram supplied with each machine.
1- Position the dishwasher and level the
appliance by turning the re
spective
height-adjustable feet. (Fig.4)
Fig. 4
2- Connect the solenoid valve, which feed
s
the
machine, to the water shut
off
valve,
using a
flexible line. (Fig.5) Each
machine must
have its own water
supply line.
Fig. 5
2A1 – WATER SUPPLY PRESSURE Check
that
the
dynamic water supply pressure,
measured between the appliance and the
main
s
, is between
29
and
58 psi
. If
the
pressure is too high,
install
a suitable
pressure reducer on the inlet pipe. If the
pressure is low, install an additional external
pressure pump. (par.1D – Technical Data)
-
In case of new
install
or long term appliance
inactivity, drain the water line to eliminate
air
bubbles and foreign bodies present in
new or
unused water lines
.
Failure to do so
could
damage the machine.
2A2 – WATER HARDNESS
If water hardness is higher than acceptable,
install a water softener of adequate size
before the feed solenoid valve. (par.1D –
Technical Data)
If there is a high concentration of
mineral residue in the water or high
conductivity, we recommend installing the
demineralization filter for 5/7° f.
2
- INSTRUCTION FOR INSTALLER / MAINTENANCE